← Back
One family attached or semi-detached
7608 6 AVENUE
BROOKLYN · BIN 3149323
💬 Discuss this project
1925Year Built
2.5Stories
A5Building Class
R4-1Zoning
2,286 sfGross Floor Area
1Units
One family attached or semi-detached · 2,958 sf lot · 0.77 FAR built · Flood zone X
Locations of Work
Architecture
Floor 12p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/28/2023$900K—Private party → Private party$394/sf building
12/14/2015$600K—Private party → Private party$262/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THINK DESIGN ARCHITECTURE306/30/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
THINK DESIGN ARCHITECTURE203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SLATTERY DRILLING LLCGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THINK DESIGN ARCHITECTURA683206/30/2025
Building Lifecycle
All (17)Filed (3)Permit Issued (2)Signed Off (2)Inspection (1)Special Inspection (9)
08/20/2025
Signed off — Alteration
APPLICATION IS FILED FOR REMOVAL AND RELOCATION OF PORCH, DOOR & WINDOWS AT FRONT OF THE HOUSE & INSTALLATION OF PORCH AT REAR OF THE HOUSE. NO CHANGE TO USE OR OCCUPANCY FILED UNDER THIS APPLICATION. ALL WORK AS PER PLANS SUBMITTED HEREWITH.
B01182022-I1
08/20/2025
Signed off — Alteration
APPLICATION IS FILED FOR THE INSTALLATION OF 8'-0' HIGH TEMPORARY CONSTRUCTION FENCE FILED IN CONJUNCTION WITH FUTURE NEW BUILDING. ALL WORK AS PER PLANS SUBMITTED HEREWITH. NO CHANGE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION.
B01188440-I1
08/18/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/30/2025
Filed — Alteration
APPLICATION IS FILED FOR REMOVAL AND RELOCATION OF PORCH, DOOR & WINDOWS AT FRONT OF THE HOUSE & INSTALLATION OF PORCH AT REAR OF THE HOUSE. NO CHANGE TO USE OR OCCUPANCY FILED UNDER THIS APPLICATION. ALL WORK AS PER PLANS SUBMITTED HEREWITH.
B01182022-P1
06/30/2025
Special inspection requirement — Concrete - Cast-In-Place
Frank Martarella III
06/30/2025
Special inspection requirement — Subgrade Inspections
Frank Martarella III
06/30/2025
Special inspection requirement — Fire-Resistance Rated Construction
Frank Martarella III
06/30/2025
Special inspection requirement — Energy Code Compliance Inspections
Frank Martarella III
06/30/2025
Special inspection requirement — Air barrier - visual inspection
Frank Martarella III
06/30/2025
Special inspection requirement — Fenestration air leakage
Frank Martarella III
06/30/2025
Special inspection requirement — Fenestration areas
Frank Martarella III
06/30/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Frank Martarella III
06/30/2025
Special inspection requirement — Insulation placement and R values
Frank Martarella III
03/18/2025
Permit issued — General Construction
B01182022-I1-GC
03/18/2025
Permit issued — Construction Fence
B01188440-I1-FN
03/10/2025
Filed — Alteration
APPLICATION IS FILED FOR REMOVAL AND RELOCATION OF PORCH, DOOR & WINDOWS AT FRONT OF THE HOUSE & INSTALLATION OF PORCH AT REAR OF THE HOUSE. NO CHANGE TO USE OR OCCUPANCY FILED UNDER THIS APPLICATION. ALL WORK AS PER PLANS SUBMITTED HEREWITH.
B01182022-I1
03/06/2025
Filed — Alteration
APPLICATION IS FILED FOR THE INSTALLATION OF 8'-0' HIGH TEMPORARY CONSTRUCTION FENCE FILED IN CONJUNCTION WITH FUTURE NEW BUILDING. ALL WORK AS PER PLANS SUBMITTED HEREWITH. NO CHANGE, EGRESS OR OCCUPANCY FILED UNDER THIS APPLICATION.
B01188440-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offSLATTERY DRILLING LLC03/18/2025
DOB NOWConstruction FenceSigned-offSLATTERY DRILLING LLC03/18/2025
1 project · most recent 02/23/2024
FiledStatusContractorScope
02/23/2024Permit IssuedMAC ELECT'L CONTR. INC.1 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
08/18/2025Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
06/30/2025Concrete - Cast-In-PlaceFrank Martarella IIIspecial
06/30/2025Subgrade InspectionsFrank Martarella IIIspecial
06/30/2025Fire-Resistance Rated ConstructionFrank Martarella IIIprogress
06/30/2025Energy Code Compliance InspectionsFrank Martarella IIIprogress
06/30/2025Air barrier - visual inspectionFrank Martarella IIIenergy_progress
06/30/2025Fenestration air leakageFrank Martarella IIIenergy_progress
06/30/2025Fenestration areasFrank Martarella IIIenergy_progress
06/30/2025Fenestration and door U-factor and product ratingsFrank Martarella IIIenergy_progress
06/30/2025Insulation placement and R valuesFrank Martarella IIIenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/22/2026B01188440-I1Request digital key ↗
08/22/2026B01182022-P1Request digital key ↗
08/22/2026B01182022-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/22/2026B01188440-I1Open ↗
08/22/2026B01182022-P1Open ↗
08/22/2026B01182022-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B01182022-I1Open ↗
09/01/2026B01182022-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026B01182022-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/22/2026B01182022-I1Open ↗
08/22/2026B01182022-P1Open ↗