| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 02/17/2025 | $927K | — | SHENANDOAH VALLEY CLUB, INC. → 8417 7TH AVE, LLC | $362/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| M JUST ARCHITECTURE PC | 2 | 11/11/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| JUST ARCHITECTURE | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| FALLON ELECTRIC CORP | Electrical | 2 | 03/22/2026 |
| BNY CONSTRUCTION INC | General Contractor | 2 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ADAL ENGINEERING PLLC | 4205 | 2 | 11/11/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Signed-off | BNY CONSTRUCTION INC | 04/23/2026 |
| DOB NOW | General Construction | Permit Issued | BNY CONSTRUCTION INC | 12/09/2025 |
| BIS | PL | ISSUED | Z.W. PLBG & HTG CORP | 02/08/2016 |
| BIS | PL | ISSUED | Z.W. PLBG & HTG CORP | 10/05/2012 |
| BIS | MH | ISSUED | B&R CONCRETE AND EXCAVATI | 07/24/2012 |
| BIS | EQ | ISSUED | B&R CONCRETE AND EXCAVATI | 07/24/2012 |
| BIS | — | ISSUED | DURNEY PLUMBING | 04/19/1996 |
| BIS | PL | ISSUED | DURNEY PLUMBING | 04/19/1996 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 11/11/2025 | Signed-off | BNY CONSTRUCTION INC | Heating and Air Conditioning Systems, Others | Heat / Cool Daikin AC-1 & AC-1 Model #FTXC12AVJU9 12,000 BTU · Fan Coil Indoor ×2 AC-2 & AC-2 Model #FTXS18WVJU9 18,000 BTU · Fan Coil Indoor ×2 AC-3 & AC-3 Model #FTXR12WVJUW9 12,000 BTU · Fan Coil Indoor ×2 CU-1 Model #3MXM24AVJU9 24,000 BTU · Condensing Unit ×1 CU-2 Model #4MXLH36WVJU9 34,400 BTU · Condensing Unit ×1 CU-3 Model #3MXL24WMVJU9 24,000 BTU · Condensing Unit ×1 Other Panasonic TX-1 Model #FV-0511VFL1 110 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/11/2025 | Complete | GAUGE TECH ELECTRIC INC | General Wiring |
| 11/12/2024 | Complete | FALLON ELECTRIC CORP | General Wiring |
| 12/17/2018 | Complete | FALLON ELECTRIC CORP | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/02/2025 | Permit Issued | BNY CONSTRUCTION INC | Tenant Protection Plan 72 Hour |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 11/10/2025 | HVAC-R and service water piping design and insulation | Dariusz Makara | energy_progress |
| 11/10/2025 | Maintenance information | Dariusz Makara | energy_progress |
| 11/10/2025 | Fire-Resistant Penetrations and Joints | Dariusz Makara | special |
| 11/10/2025 | Energy Code Compliance Inspections | Dariusz Makara | progress |
| 11/10/2025 | HVAC-R and service water heating system controls | Dariusz Makara | energy_progress |
| 11/10/2025 | HVAC-R and service water heating equipment | Dariusz Makara | energy_progress |
| 11/04/2025 | Mechanical Systems | Dariusz Makara | special |
| 11/04/2025 | Final | Dariusz Makara | progress |