← Back
Two family brick
452 85 STREET
BROOKLYN · BIN 3153153
💬 Discuss this project
1925Year Built
2Stories
B1Building Class
R4-1Zoning
2,288 sfGross Floor Area
2Units
24 Open Violations 23 unresolved · 1 paperwork only ▸FDNY Report ↗
Two family brick · 2,500 sf lot · 0.92 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Roof2p · 1 filing · 11 docs
Floor 21p · 1 filing · 11 docs
Floor 1
Cellar3p · 1 filing · 11 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/07/2023$1.2M—— → —$530/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
C&B CONSULTING ENGINEERS LLC107/02/2024
JENNY PEYSIN ARCHITECTURE PLLC105/29/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEXUS CONSULTING NYC, INC403/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STUDIO NYANDAK ARCHITECTU8378107/02/2024
Building Lifecycle
All (51)Filed (2)Violation (24)Objection (20)Special Inspection (5)
12/12/2025
Violation issued (ECB, open)
Construction
07/02/2024
Filed — Alteration
Plumbing work for a residential building. No change in use, egress, or occupancy.
B01035341-S2
06/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TENZIN NYANDAK
06/26/2024
Special inspection requirement — Energy Code Compliance Inspections
TENZIN NYANDAK
06/26/2024
Special inspection requirement — HVAC-R and service water heating equipment
TENZIN NYANDAK
06/26/2024
Special inspection requirement — HVAC-R and service water heating system controls
TENZIN NYANDAK
06/26/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
TENZIN NYANDAK
06/18/2024
Objection resolved — Addressed
06/17/2024
Objection raised — Energy
06/17/2024
Objection resolved — Addressed
06/12/2024
Objection resolved — Addressed
06/12/2024
Objection resolved — Addressed
06/12/2024
Objection resolved — Addressed
06/12/2024
Objection resolved — Addressed
06/12/2024
Objection resolved — Addressed
06/12/2024
Objection resolved — Addressed
06/12/2024
Objection resolved — Addressed
06/12/2024
Objection resolved — Addressed
06/04/2024
Objection raised — Inspections
06/04/2024
Objection raised
06/04/2024
Objection raised
06/04/2024
Objection raised
06/04/2024
Objection raised — Inspections
06/04/2024
Objection raised — Other
06/04/2024
Objection raised — Fire_Protection
06/04/2024
Objection raised — Accessibility
06/04/2024
Objection raised
05/29/2024
Filed — Alteration
Plumbing work for a residential building. No change in use, egress, or occupancy.
B01035341-I1
03/12/2024
Violation issued (ECB, open)
Construction
09/15/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/03/2022
Violation issued (HPD, open)
B
08/31/2022
Violation issued (HPD, open)
B
08/15/2022
Violation issued (HPD, open)
I
08/13/2022
Violation issued (HPD, open)
A
08/13/2022
Violation issued (HPD, open)
A
08/13/2022
Violation issued (HPD, open)
A
08/13/2022
Violation issued (HPD, open)
C
08/13/2022
Violation issued (HPD, open)
C
08/13/2022
Violation issued (HPD, open)
A
08/13/2022
Violation issued (HPD, open)
C
08/13/2022
Violation issued (HPD, open)
C
08/13/2022
Violation issued (HPD, open)
C
08/13/2022
Violation issued (HPD, open)
C
08/13/2022
Violation issued (HPD, open)
A
03/31/2009
Violation issued (HPD, open)
A
03/31/2009
Violation issued (HPD, open)
A
03/31/2009
Violation issued (HPD, open)
A
03/31/2009
Violation issued (HPD, open)
B
03/31/2009
Violation issued (HPD, open)
A
03/31/2009
Violation issued (HPD, open)
B
03/31/2009
Violation issued (HPD, open)
B
Nothing on file for this building.
1 project · most recent 07/02/2024
Gas Water/Sanitary
FiledStatusContractorScope
07/02/2024——Gas, Water/Sanitary
1 project · most recent 08/17/2023
FiledStatusContractorScope
08/17/2023Permit IssuedELMAC ELECTRIC INC.2 meters, 2 new_meters
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
06/26/2024Fire-Resistant Penetrations and JointsTENZIN NYANDAKspecial
06/26/2024Energy Code Compliance InspectionsTENZIN NYANDAKprogress
06/26/2024HVAC-R and service water heating equipmentTENZIN NYANDAKenergy_progress
06/26/2024HVAC-R and service water heating system controlsTENZIN NYANDAKenergy_progress
06/26/2024HVAC-R and service water piping design and insulationTENZIN NYANDAKenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026B01035341-S2Request digital key ↗
08/14/2026B01035341-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature4
08/28/2026B01035341-S2Open ↗
08/28/2026B01035341-S2Open ↗
08/28/2026B01035341-S2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026B01035341-I1Open ↗
08/24/2026B01035341-S2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026B01035341-S2Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/24/2026B01035341-S2Open ↗
08/14/2026B01035341-I1Open ↗