← Back
Two family frame
2044 71 STREET
BROOKLYN · BIN 3158048
💬 Discuss this project
1925Year Built
2Stories
B2Building Class
R5Zoning
1,764 sfGross Floor Area
2Units
Two family frame · 2,200 sf lot · 0.8 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NYX ENGINEERING, PLLC207/14/2026
JX FLAME SOLUTION INC306/17/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW LAND CONSTRUCTION NYGeneral Contractor107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NYX ENGINEERING, PLLC6118507/14/2026
Building Lifecycle
All (38)Filed (5)Permit Issued (2)Signed Off (1)Inspection (6)Special Inspection (24)
08/13/2026
Signed off — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK TYPE. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01394008-I1
07/31/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/30/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/21/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/14/2026
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK TYPE. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01394008-P1
06/24/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/24/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/24/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/18/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiao Huang
06/18/2026
Special inspection requirement — Energy Code Compliance Inspections
Xiao Huang
06/18/2026
Special inspection requirement — Maintenance information
Xiao Huang
06/18/2026
Special inspection requirement — HVAC-R and service water heating equipment
Xiao Huang
06/18/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Xiao Huang
06/18/2026
Special inspection requirement — HVAC-R and service water heating system controls
Xiao Huang
06/17/2026
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK TYPE. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01394008-P3
06/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiao Huang
06/10/2026
Special inspection requirement — Energy Code Compliance Inspections
Xiao Huang
06/10/2026
Special inspection requirement — HVAC-R and service water heating equipment
Xiao Huang
06/10/2026
Special inspection requirement — Maintenance information
Xiao Huang
06/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Xiao Huang
06/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
Xiao Huang
06/08/2026
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK TYPE. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01394008-P2
06/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiao Huang
06/04/2026
Special inspection requirement — Energy Code Compliance Inspections
Xiao Huang
06/04/2026
Special inspection requirement — Fenestration areas
Xiao Huang
06/04/2026
Special inspection requirement — Air barrier - visual inspection
Xiao Huang
06/04/2026
Special inspection requirement — Fenestration air leakage
Xiao Huang
06/04/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Xiao Huang
06/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiao Huang
06/04/2026
Special inspection requirement — Energy Code Compliance Inspections
Xiao Huang
06/04/2026
Special inspection requirement — HVAC-R and service water heating system controls
Xiao Huang
06/04/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Xiao Huang
06/04/2026
Special inspection requirement — Maintenance information
Xiao Huang
06/04/2026
Special inspection requirement — HVAC-R and service water heating equipment
Xiao Huang
05/28/2026
Permit issued — General Construction
B01394008-I1-GC
05/20/2026
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK TYPE. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01394008-S1
05/20/2026
Permit issued — Plumbing
B01394008-S1-PL
04/29/2026
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK TYPE. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01394008-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNEW LAND CONSTRUCTION NY05/28/2026
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.05/20/2026
1 project · most recent 07/14/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/14/2026Signed-offAMERICAN STANDARD P&H CORGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
07/31/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/30/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/21/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/24/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/24/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/24/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
06/18/2026Fire-Resistant Penetrations and JointsXiao Huangspecial
06/18/2026Energy Code Compliance InspectionsXiao Huangprogress
06/18/2026Maintenance informationXiao Huangenergy_progress
06/18/2026HVAC-R and service water heating equipmentXiao Huangenergy_progress
06/18/2026HVAC-R and service water piping design and insulationXiao Huangenergy_progress
06/18/2026HVAC-R and service water heating system controlsXiao Huangenergy_progress
06/10/2026Fire-Resistant Penetrations and JointsXiao Huangspecial
06/10/2026Energy Code Compliance InspectionsXiao Huangprogress
06/10/2026HVAC-R and service water heating equipmentXiao Huangenergy_progress
06/10/2026Maintenance informationXiao Huangenergy_progress
06/10/2026HVAC-R and service water piping design and insulationXiao Huangenergy_progress
06/10/2026HVAC-R and service water heating system controlsXiao Huangenergy_progress
06/04/2026Fire-Resistant Penetrations and JointsXiao Huangspecial
06/04/2026Energy Code Compliance InspectionsXiao Huangprogress
06/04/2026Fenestration areasXiao Huangenergy_progress
06/04/2026Air barrier - visual inspectionXiao Huangenergy_progress
06/04/2026Fenestration air leakageXiao Huangenergy_progress
06/04/2026Fenestration and door U-factor and product ratingsXiao Huangenergy_progress
06/04/2026Fire-Resistant Penetrations and JointsXiao Huangspecial
06/04/2026Energy Code Compliance InspectionsXiao Huangprogress
06/04/2026HVAC-R and service water heating system controlsXiao Huangenergy_progress
06/04/2026HVAC-R and service water piping design and insulationXiao Huangenergy_progress
06/04/2026Maintenance informationXiao Huangenergy_progress
06/04/2026HVAC-R and service water heating equipmentXiao Huangenergy_progress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/16/2026B01394008-S1Request digital key ↗
08/16/2026B01394008-I1Request digital key ↗
08/16/2026B01394008-P3Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWRestrictive Declaration/Easement 13
08/16/2026B01394008-S1Open ↗
08/16/2026B01394008-P3Open ↗
08/16/2026B01394008-P2Open ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature8
09/29/2026B01394008-S1Open ↗
09/29/2026B01394008-S1Open ↗
09/02/2026B01394008-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/16/2026B01394008-S1Open ↗
08/16/2026B01394008-I1Open ↗
08/16/2026B01394008-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/29/2026B01394008-S1Open ↗
09/02/2026B01394008-P1Open ↗
08/29/2026B01394008-P3Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/16/2026B01394008-P3Open ↗
08/16/2026B01394008-I1Open ↗
08/16/2026B01394008-P2Open ↗
Showing 3 of 5 on file for this type