← Back
Two family brick
1719 73 STREET
BROOKLYN · BIN 3158513
💬 Discuss this project
1940Year Built
2Stories
B1Building Class
R5Zoning
2,300 sfGross Floor Area
2Units
Two family brick · 3,783 sf lot · 0.61 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 22p · 1 filing · 8 docs
Floor 11p · 1 filing · 4 docs
Cellar2p · 1 filing · 4 docs
1 job · most recent 04/07/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
04/07/2026Signed-offS & L PLUMBING INCGas, Storm, Water/Sanitary
1 job · most recent 08/20/2026
General Wiring
FiledStatusContractorScope
08/20/2026CompleteKJK ELECTRIC INCGeneral Wiring
Building Lifecycle
All (20)Filed (4)Permit Issued (3)Signed Off (2)Inspection (5)Special Inspection (6)
05/11/2026
Signed off — Alteration
B01342384-I1
05/11/2026
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, 1ST AND 2ND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES ON 1ST AND 2ND FLOOR; NEW 2-PCRESTROOM, WASHER, DRYER, BOILERS AND HOT WATER HEATERS IN CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APP
B01342389-I1
04/28/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/21/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
04/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Hugues Paul
04/08/2026
Special inspection requirement — Energy Code Compliance Inspections
Hugues Paul
04/08/2026
Special inspection requirement — Fire-Resistance Rated Construction
Hugues Paul
04/07/2026
Filed — Alteration
B01342384-P1
04/07/2026
Filed — Alteration
RENOVATION OF EXISTING CELLAR, 1ST AND 2ND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES ON 1ST AND 2ND FLOOR; NEW 2-PCRESTROOM, WASHER, DRYER, BOILERS AND HOT WATER HEATERS IN CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APP
B01342389-P1
04/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Hugues Paul
04/06/2026
Special inspection requirement — Energy Code Compliance Inspections
Hugues Paul
04/06/2026
Special inspection requirement — Fire-Resistance Rated Construction
Hugues Paul
03/11/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/11/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/09/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/06/2026
Permit issued — Plumbing
B01342389-I1-PL
01/14/2026
Permit issued — General Construction
B01342384-I1-GC
01/09/2026
Permit issued — Plumbing
B01342389-I1-PL
01/07/2026
Filed — Alteration
B01342384-I1
01/07/2026
Filed — Alteration
RENOVATION OF EXISTING CELLAR, 1ST AND 2ND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES ON 1ST AND 2ND FLOOR; NEW 2-PCRESTROOM, WASHER, DRYER, BOILERS AND HOT WATER HEATERS IN CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APP
B01342389-I1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/18/2025$1.9M—Private party → Private party$839/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PAUL ENGR. INSP. (PEI) CONSULTANTS404/07/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KALE CONSTRUCTION INCGeneral Contractor104/09/2026
CATMAN PLUMBING INCPlumbing107/08/2026
S & L PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PAUL ENGINEERING INSPECTI4672204/07/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offS & L PLUMBING INC03/06/2026
DOB NOWGeneral ConstructionSigned-offKALE CONSTRUCTION INC01/14/2026
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC01/09/2026
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/28/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/21/2026Fail-Final General Construction Non-Directive 14FailView ↗
03/11/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/11/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/09/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
04/08/2026Fire-Resistant Penetrations and JointsHugues Paulspecial
04/08/2026Energy Code Compliance InspectionsHugues Paulprogress
04/08/2026Fire-Resistance Rated ConstructionHugues Paulprogress
04/06/2026Fire-Resistant Penetrations and JointsHugues Paulspecial
04/06/2026Energy Code Compliance InspectionsHugues Paulprogress
04/06/2026Fire-Resistance Rated ConstructionHugues Paulprogress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/19/2026B01342389-I1Request digital key ↗
08/19/2026B01342389-P1Request digital key ↗
08/19/2026B01342384-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/19/2026B01342389-P1Open ↗
08/19/2026B01342389-I1Open ↗
08/19/2026B01342384-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B01342384-P1Open ↗
08/26/2026B01342384-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B01342384-P1Open ↗
08/26/2026B01342384-I1Open ↗