← Back
Three families
2244 85 STREET
BROOKLYN · BIN 3165924
💬 Discuss this project
1920Year Built
2Stories
C0Building Class
R5Zoning
2,800 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Three families · 2,750 sf lot · 1.02 FAR built · Flood zone X
Locations of Work
StructuralPlumbing
Cellar2p · 2 filings · 17 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/22/2022$1.6M—— → —$568/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JIAN ENGINEERING PLLC509/14/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JRK CREATIVE1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FIRST STAR CONSTRUCTION *General Contractor207/08/2026
VILLAGE P & H NY INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JIAN ENGINEERING PLLC7397509/14/2023
Building Lifecycle
All (40)Filed (5)Permit Issued (3)Signed Off (3)Violation (11)Inspection (7)Special Inspection (11)
06/06/2025
Violation issued (HPD, closed)
A
11/26/2024
Violation issued (HPD, closed)
I
01/16/2024
Signed off — Alteration
INTERIOR RENOVATION FOR EXISTING 2 FAMILY DWELLING UNITS,ON CELLAR,1ST FL,2ND FL,NEW PARTITION WALL AND PLUMBING WORK FILING SEPARATE APPLICATION .NO CHANGE IN USE,MEANS OF EGRESS OR OCCUPANCY.
B00761923-I1
01/16/2024
Signed off — Alteration
B08038796-I1
01/11/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/27/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/21/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/16/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
JIAN DENG
09/16/2023
Special inspection requirement — Energy Code Compliance Inspections
JIAN DENG
09/16/2023
Special inspection requirement — Lighting in dwelling units
JIAN DENG
09/14/2023
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING 2 FAMILY DWELLING UNITS,ON CELLAR,1ST FL,2ND FL,NEW PARTITION WALL AND PLUMBING WORK FILING SEPARATE APPLICATION .NO CHANGE IN USE,MEANS OF EGRESS OR OCCUPANCY.
B00761923-P1
08/04/2023
Signed off — Alteration
EXIST.2 FAMILY DWELLING UNITS,ON CELLAR,1ST FL,2ND FL,PLUMBING WORK AS PER PLAN SUBMITTED.GENERAL CONSTRUCTION FILING SEPARATE APPLICATION JOB #B00761923-I1.NO CHANGE IN MEANS IN MEANS OF USE,EGRESS AND OCCUPANCY.
B00762788-I1
06/13/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/21/2023
Violation issued (HPD, closed)
A
02/07/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/11/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/11/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/01/2023
Filed — Alteration
EXIST.2 FAMILY DWELLING UNITS,ON CELLAR,1ST FL,2ND FL,PLUMBING WORK AS PER PLAN SUBMITTED.GENERAL CONSTRUCTION FILING SEPARATE APPLICATION JOB #B00761923-I1.NO CHANGE IN MEANS IN MEANS OF USE,EGRESS AND OCCUPANCY.
B00762788-P1
12/20/2022
Permit issued — Structural
B08038796-I1-ST
12/16/2022
Filed — Alteration
B08038796-I1
12/12/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
JIAN DENG
12/12/2022
Special inspection requirement — Energy Code Compliance Inspections
JIAN DENG
12/12/2022
Special inspection requirement — Lighting in dwelling units
JIAN DENG
12/12/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
JIAN DENG
12/12/2022
Special inspection requirement — Energy Code Compliance Inspections
JIAN DENG
12/12/2022
Special inspection requirement — HVAC-R and service water heating equipment
JIAN DENG
12/12/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
JIAN DENG
12/12/2022
Special inspection requirement — HVAC-R and service water heating system controls
JIAN DENG
11/09/2022
Violation issued (HPD, closed)
I
09/22/2022
Permit issued — Plumbing
B00762788-I1-PL
08/02/2022
Permit issued — General Construction
B00761923-I1-GC
07/21/2022
Filed — Alteration
EXIST.2 FAMILY DWELLING UNITS,ON CELLAR,1ST FL,2ND FL,PLUMBING WORK AS PER PLAN SUBMITTED.GENERAL CONSTRUCTION FILING SEPARATE APPLICATION JOB #B00761923-I1.NO CHANGE IN MEANS IN MEANS OF USE,EGRESS AND OCCUPANCY.
B00762788-I1
07/20/2022
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING 2 FAMILY DWELLING UNITS,ON CELLAR,1ST FL,2ND FL,NEW PARTITION WALL AND PLUMBING WORK FILING SEPARATE APPLICATION .NO CHANGE IN USE,MEANS OF EGRESS OR OCCUPANCY.
B00761923-I1
02/23/2022
Violation issued (HPD, closed)
A
02/23/2022
Violation issued (HPD, closed)
I
07/06/2021
Violation issued (ECB, closed)
Construction
04/07/2021
Violation issued (HPD, closed)
A
10/15/2018
Violation issued (HPD, closed)
I
11/17/2017
Violation issued (HPD, closed)
I
10/07/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offFIRST STAR CONSTRUCTION *12/20/2022
DOB NOWPlumbingSigned-offVILLAGE P & H NY INC09/22/2022
DOB NOWGeneral ConstructionSigned-offFIRST STAR CONSTRUCTION *08/02/2022
BIS—ISSUEDAB PLUMBING INC12/18/2015
BISPLISSUEDCREATIVE PLUMBING IN12/18/2015
2 jobs · most recent 08/25/2022
General Wiring
FiledStatusContractorScope
08/25/2022Permit IssuedJ Y ELECTRIC INCGeneral Wiring
12/13/2021CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
01/11/2024Pass-Final General Construction Non-Directive 14PassView ↗
12/27/2023Fail-Final General Construction Non-Directive 14FailView ↗
09/21/2023Fail-Final General Construction Non-Directive 14FailView ↗
06/13/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/07/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/11/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/11/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
09/16/2023Fire-Resistant Penetrations and JointsJIAN DENGspecial
09/16/2023Energy Code Compliance InspectionsJIAN DENGprogress
09/16/2023Lighting in dwelling unitsJIAN DENGenergy_progress
12/12/2022Fire-Resistant Penetrations and JointsJIAN DENGspecial
12/12/2022Energy Code Compliance InspectionsJIAN DENGprogress
12/12/2022Lighting in dwelling unitsJIAN DENGenergy_progress
12/12/2022Fire-Resistant Penetrations and JointsJIAN DENGspecial
12/12/2022Energy Code Compliance InspectionsJIAN DENGprogress
12/12/2022HVAC-R and service water heating equipmentJIAN DENGenergy_progress
12/12/2022HVAC-R and service water piping design and insulationJIAN DENGenergy_progress
12/12/2022HVAC-R and service water heating system controlsJIAN DENGenergy_progress
▾Documents — 74 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/29/2026B00761923-I1Request digital key ↗
08/29/2026B00761923-P1Request digital key ↗
08/29/2026B00762788-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits12
▸BISPLAN / WORK APPROVAL APPLICATION9
04/27/2022321021871Open ↗
04/21/2022321021871Open ↗
03/31/2022321021871Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION2
12/23/2015321021871Open ↗
12/23/2015321021871Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
12/07/2016321021871Open ↗
▸Zoning, Tax Lot & Property Records7
▸DOB NOWRestrictive Declaration/Easement 14
08/13/2026B00761923-P1Open ↗
08/13/2026B00761923-I1Open ↗
08/13/2026B00762788-I1Open ↗
Showing 3 of 4 on file for this type
▸BISVERIFY TAX LOT1
11/23/2021321021871Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
08/03/2015321021871Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
11/23/2021321021871Open ↗
▸Seals & Professional Certifications18
▸DOB NOWProgress Inspector Seal & Signature8
08/31/2026B00761923-I1Open ↗
08/31/2026B00761923-I1Open ↗
08/25/2026B00762788-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/29/2026B00761923-P1Open ↗
08/29/2026B00761923-I1Open ↗
08/29/2026B00762788-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/31/2026B00761923-I1Open ↗
08/25/2026B00762788-P1Open ↗
08/23/2026B00761923-P1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
12/23/2015321021871Open ↗
11/05/2014321021871Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
06/22/2015321021871Open ↗
11/05/2014321021871Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
12/21/2021321021871Open ↗
▸BISDETECTOR:CARBON MONOXIDE-CERT.OF INSTALL1
12/21/2021321021871Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
12/23/2015321021871Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/29/2026B00761923-P1Open ↗
08/29/2026B00761923-I1Open ↗
08/29/2026B00762788-P1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/31/2015321021871Open ↗
▸Energy Compliance5
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026B00761923-I1Open ↗
08/13/2026B00762788-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/24/2021321021871Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
12/21/2021321021871Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
12/23/2015321021871Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/24/2021321021871Open ↗
▸Approvals, Objections & Sign-offs7
▸BISSCHEDULE A - OCCUPANCY / USE7
04/27/2022321021871Open ↗
04/21/2022321021871Open ↗
03/31/2022321021871Open ↗
Showing 3 of 7 on file for this type
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT (FINAL): PW31
12/17/2021321021871Open ↗
▸BISHIC LICENSE OR AFFIDAVIT1
12/23/2015321021871Open ↗
▸BISCOST AFFIDAVIT1
11/05/2014321021871Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION3
02/02/2022321021871Open ↗
04/20/2016321021871Open ↗
08/03/2015321021871Open ↗
▸BISEFILING COVER SHEET1
11/05/2014321021871Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
08/03/2015321021871Open ↗