← Back
One family attached or semi-detached
8846 16 AVENUE
BROOKLYN · BIN 3169252
💬 Discuss this project
1950Year Built
2Stories
A5Building Class
R4Zoning
1,240 sfGross Floor Area
1Units
One family attached or semi-detached · 1,937 sf lot · 0.64 FAR built · Flood zone X
Locations of Work
Architecture
Floor 21p · 1 filing · 11 docs
Floor 1
Cellar2p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/21/2021$882K—Private party → Private party$711/sf building
01/16/2015$720K—Private party → Private party$581/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GREAT WALL CONSULTANT PROFESSIONAL405/20/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SO PLUMBING & HEATING INCPlumbing507/08/2026
MBC CONSTRUCTION CORPGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREAT WALL CONSULTANT P.E5633405/20/2021
Building Lifecycle
All (25)Filed (4)Permit Issued (2)Signed Off (2)Objection (12)Special Inspection (5)
05/28/2021
Signed off — Alteration
Propose interior renovation of existing 1 family building with new partitions work and finish work as per plan. No change in use, egress, or occupancy.
B00473530-I1
05/28/2021
Signed off — Alteration
Propose plumbing work of existing 1 family building in conjunction with DOB Now Construction #B00473530 as per plan. No change in use, egress, or occupancy.
B00473532-I1
05/21/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiong Wei Wu
05/21/2021
Special inspection requirement — Energy Code Compliance Inspections
Xiong Wei Wu
05/21/2021
Special inspection requirement — Fire-Resistance Rated Construction
Xiong Wei Wu
05/20/2021
Filed — Alteration
Propose plumbing work of existing 1 family building in conjunction with DOB Now Construction #B00473530 as per plan. No change in use, egress, or occupancy.
B00473532-P1
05/20/2021
Filed — Alteration
Propose interior renovation of existing 1 family building with new partitions work and finish work as per plan. No change in use, egress, or occupancy.
B00473530-P1
05/20/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiong Wei Wu
05/20/2021
Special inspection requirement — Energy Code Compliance Inspections
Xiong Wei Wu
03/30/2021
Permit issued — Plumbing
B00473532-I1-PL
03/17/2021
Permit issued — General Construction
B00473530-I1-GC
03/03/2021
Objection raised — Other
03/03/2021
Objection resolved — Addressed
03/03/2021
Objection raised — Energy
03/03/2021
Objection resolved — Addressed
03/03/2021
Objection raised — Admin
03/03/2021
Objection resolved — Addressed
03/03/2021
Objection raised — Structural
03/03/2021
Objection resolved — Addressed
03/02/2021
Objection raised — Inspections
03/02/2021
Objection resolved — Addressed
03/02/2021
Objection raised — Inspections
03/02/2021
Objection resolved — Addressed
03/01/2021
Filed — Alteration
Propose interior renovation of existing 1 family building with new partitions work and finish work as per plan. No change in use, egress, or occupancy.
B00473530-I1
03/01/2021
Filed — Alteration
Propose plumbing work of existing 1 family building in conjunction with DOB Now Construction #B00473530 as per plan. No change in use, egress, or occupancy.
B00473532-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offNICHOLAS SUIDA03/30/2021
DOB NOWGeneral ConstructionSigned-offMBC CONSTRUCTION CORP03/17/2021
1 project · most recent 04/03/2019
FiledStatusContractorScope
04/03/2019Permit IssuedTRIANGLE ELECTRIC INC.1 meters
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/21/2021Fire-Resistant Penetrations and JointsXiong Wei Wuspecial
05/21/2021Energy Code Compliance InspectionsXiong Wei Wuprogress
05/21/2021Fire-Resistance Rated ConstructionXiong Wei Wuprogress
05/20/2021Fire-Resistant Penetrations and JointsXiong Wei Wuspecial
05/20/2021Energy Code Compliance InspectionsXiong Wei Wuprogress
▾Documents — 23 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch - General Construction2
09/01/2026B00473530-P1Request digital key ↗
08/15/2026B00473530-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing2
09/01/2026B00473532-P1Request digital key ↗
08/15/2026B00473532-I1Request digital key ↗
▸DOB NOWPlans/Sketch2
09/01/2026B00473532-P1Request digital key ↗
08/15/2026B00473532-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 14
09/01/2026B00473530-P1Open ↗
09/01/2026B00473532-P1Open ↗
08/15/2026B00473530-I1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/01/2026B00473530-I1Open ↗
09/01/2026B00473530-P1Open ↗
09/01/2026B00473532-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026B00473530-I1Open ↗
08/28/2026B00473530-I1Open ↗
08/24/2026B00473532-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026B00473530-I1Open ↗
08/24/2026B00473532-P1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/01/2026B00473530-P1Open ↗
09/01/2026B00473532-P1Open ↗
08/15/2026B00473530-I1Open ↗
Showing 3 of 4 on file for this type