DOB01/12/2026UNPERMITTED/UNDOCUMENTED EXCAVATION/FOUNDATION WORK PERFORMED IN CELLAR WITH NO STRUCTURAL DETAIL/DRAWINGS/PERMITS FILED AS PER CODE.
DOB01/12/2026DESCRIPTION OF VIOLATION: UNPERMITTED/UNDOCUMENTED EXCAVATION/FOUNDATION WORK PERFORMED IN CELLAR WITH NO STRUCTURAL DETAIL/DRAWINGS/PERMITS FILED AS PER CODE. ENGINEERS REPORT FOR STRUCTURAL STABILITY REQUIRED.
ECB01/12/2026AT TIME OF INSPECTION, OBSERVED WORK OCCURRING WITHOUT APPROVED PLANS. EXCAVATION WORK IN BASEMENT AND CONSTRUCTION OF BRACING ON FIRST AND SECOND FLOOR. HAZARDOUS CONDITIONS CREATED FOR UNDOCUMENTED SCOPE OF W$2K due
ECB01/12/2026AT TIME OF INSPECTION, OBSERVED BASEMENT BEING EXCAVATED AND SOIL BEING REMOVED. UNDERPINNED WAS OCCURRING AT PERIMETER OF FOUNDATION WALLS. HAZARD CREATED BY UNDOCUMENTED AND UNPERMITTED WORK. ECB ISSUED FOR W$2K due
ECB01/12/2026AT TIME OF INSPECTION, OBSERVED PIPING REMOVED AND UNCAPPED. HAZARDOUS CONDITIONS CREATED AS UTILITIES ARE STILL RUNNING DURING THIS UNPERMITTED WORK. ECB ISSUED FOR WORK WITHOUT PLUMBING PERMIT., OBTAIN PERMIT$2K due
ECB01/12/2026AT TIME OF INSPECTION, OBSERVED NEW FORMS AND CONCRETE POURED UNDER FOUNDATION FOOTINGS. UNPERMITTED AND UNDOCUMENTED WORK HAS CREATED A STRUCTURAL HAZARD. ECB ISSUED FOR WORK WITHOUT FOUNDATION PERMIT., OBTAIN$2K due
ECB01/12/2026AT TIME OF INSPECTION, OBSERVED NO APPROVED PLAN ON SITE. HAZARD CREATED AS WORK IS BEING PREFORMED WITHOUT DRAWINGS BY WORKERS. ECB ISSUED FOR FAILURE TO MAINTAIN DRAWINGS ON SITE., MAINTAIN/DISPLAY REQUIRED D$1K due
ECB01/12/2026AT TIME OF INSPECTION, OBSERVED CONSTRUCTED FENCE NOT BUILT PER CODE. FENCE IS SWING IS ENDANGERING THE PUBLIC AS THERE IS AN OUTWARD INTO THE SIDEWALK. ECB ISSUED FOR GATE SWING INTO AREAS ACCESSIBLE TO THE PU$2K due
Miscellaneous one family · Owner of record: 1235 E 10TH ST, LLC · 2,075 sf lot · 0.7 FAR built · Flood zone X