← Back
Two family converted from one family
1841 WEST 8 STREET
BROOKLYN · BIN 3178045
💬 Discuss this project
1915Year Built
2Stories
B3Building Class
R5BZoning
1,482 sfGross Floor Area
2Units
0 Open Violations
Two family converted from one family · 1,595 sf lot · 0.93 FAR built · Flood zone X500
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
CellarUnder Construction4p · 1 filing · 11 docs
1 job · most recent 06/13/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/13/2026Permit IssuedAMERICAN STANDARD P&H CORGas, Water/Sanitary
1 job · most recent 03/30/2025
General Wiring
FiledStatusContractorScope
03/30/2025CompleteMICHAEL F. ADANUNCIO ELECGeneral Wiring
Building Lifecycle
All (18)Filed (2)Permit Issued (2)Violation (1)Objection (3)Special Inspection (10)
07/28/2026
Permit issued — General Construction
B01410568-I1-GC
06/24/2026
Permit issued — Plumbing
B01410568-S1-PL
06/13/2026
Filed — Alteration
FILING PLUMBING WORK TYPE TO CONVERT FROM OIL TO GAS FIRED BOILER. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01410568-S1
06/12/2026
Objection raised — Other
06/12/2026
Objection raised — Other
06/12/2026
Objection raised — Other
06/05/2026
Filed — Alteration
FILING PLUMBING WORK TYPE TO CONVERT FROM OIL TO GAS FIRED BOILER. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01410568-I1
06/05/2026
Special inspection requirement — Fire-Resistance Rated Construction
Xiao Huang
06/04/2026
Special inspection requirement — Tenant Protection Plan Compliance
Xiao Huang
06/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiao Huang
06/03/2026
Special inspection requirement — HVAC-R and service water heating equipment
Xiao Huang
06/03/2026
Special inspection requirement — HVAC-R and service water heating system controls
Xiao Huang
06/03/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Xiao Huang
06/03/2026
Special inspection requirement — Maintenance information
Xiao Huang
06/03/2026
Special inspection requirement — Tenant Protection Plan Compliance
Xiao Huang
06/03/2026
Special inspection requirement — Energy Code Compliance Inspections
Xiao Huang
06/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiao Huang
11/30/2005
Violation issued (ECB, closed)
Construction
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JX FLAME SOLUTION INC106/13/2026
NYX ENGINEERING, PLLC106/05/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW LAND CONSTRUCTION NYGeneral Contractor107/29/2026
AMERICAN STANDARD P&H CORORP.Plumbing106/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NYX ENGINEERING, PLLC6118206/13/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedNEW LAND CONSTRUCTION NY07/28/2026
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD P&H CORORP.06/24/2026
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
06/05/2026Fire-Resistance Rated ConstructionXiao Huangprogress
06/04/2026Tenant Protection Plan ComplianceXiao Huangspecial
06/04/2026Fire-Resistant Penetrations and JointsXiao Huangspecial
06/03/2026HVAC-R and service water heating equipmentXiao Huangenergy_progress
06/03/2026HVAC-R and service water heating system controlsXiao Huangenergy_progress
06/03/2026HVAC-R and service water piping design and insulationXiao Huangenergy_progress
06/03/2026Maintenance informationXiao Huangenergy_progress
06/03/2026Tenant Protection Plan ComplianceXiao Huangspecial
06/03/2026Energy Code Compliance InspectionsXiao Huangprogress
06/02/2026Fire-Resistant Penetrations and JointsXiao Huangspecial
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/16/2026B01410568-S1Request digital key ↗
08/14/2026B01410568-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026B01410568-I1Open ↗
08/25/2026B01410568-S1Open ↗
08/25/2026B01410568-S1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/16/2026B01410568-I1Open ↗
08/16/2026B01410568-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026B01410568-I1Open ↗
08/25/2026B01410568-S1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/16/2026B01410568-S1Open ↗
08/14/2026B01410568-I1Open ↗