← Back
Three families
1414 AVENUE H
BROOKLYN · BIN 3179302
💬 Discuss this project
1910Year Built
2.5Stories
C0Building Class
R5DZoning
2,988 sfGross Floor Area
3Units
Rent Stabilized0 Open Violations
Three families · 5,000 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CLIP ARCHITECTS508/05/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
UNIVERSAL CONSTRUCTIONGeneral Contractor107/08/2026
AMM GEN'L CONTRACTING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREAT WALL CONSULTANT P.E5633508/05/2026
Building Lifecycle
All (25)Filed (5)Permit Issued (2)Violation (9)Inspection (3)Special Inspection (6)
08/05/2026
Filed — Alteration
Propose plumbing work at Cellar of existing residential building as per plan. No change in use, egress, or occupancy.
B01400797-P3
07/31/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiong Wei Wu
07/31/2026
Special inspection requirement — Energy Code Compliance Inspections
Jaeyoung Jang
07/24/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/21/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/13/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
07/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiong Wei Wu
07/07/2026
Special inspection requirement — Energy Code Compliance Inspections
Jaeyoung Jang
07/07/2026
Special inspection requirement — Fire-Resistance Rated Construction
Jaeyoung Jang
07/07/2026
Special inspection requirement — Lighting in dwelling units
Jaeyoung Jang
07/01/2026
Filed — Alteration
Propose plumbing work at Cellar of existing residential building as per plan. No change in use, egress, or occupancy.
B01400797-P2
07/01/2026
Filed — Alteration
Propose plumbing work at Cellar of existing residential building as per plan. No change in use, egress, or occupancy.
B01400797-P1
06/04/2026
Permit issued — Plumbing
B01400797-S1-PL
06/04/2026
Permit issued — General Construction
B01400797-I1-GC
06/03/2026
Filed — Alteration
Propose plumbing work at Cellar of existing residential building as per plan. No change in use, egress, or occupancy.
B01400797-S1
06/03/2026
Filed — Alteration
Propose plumbing work at Cellar of existing residential building as per plan. No change in use, egress, or occupancy.
B01400797-I1
05/01/2026
Violation issued (HPD, closed)
A
06/06/2025
Violation issued (HPD, closed)
A
04/08/2024
Violation issued (HPD, closed)
A
03/21/2023
Violation issued (HPD, closed)
A
02/23/2022
Violation issued (HPD, closed)
A
04/07/2021
Violation issued (HPD, closed)
A
10/15/2018
Violation issued (HPD, closed)
I
11/17/2017
Violation issued (HPD, closed)
I
11/03/2016
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMM GEN'L CONTRACTING INC06/04/2026
DOB NOWGeneral ConstructionSigned-offUNIVERSAL CONSTRUCTION06/04/2026
1 project · most recent 08/05/2026
Gas
FiledStatusContractorScope
08/05/2026Signed-offAMM GEN'L CONTRACTING INCGas
1 project · most recent 05/07/2026
FiledStatusContractorScope
05/07/2026Permit IssuedHIGH LEG 208 VOLTS ELECL4 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/24/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/21/2026Fail-Final General Construction Non-Directive 14FailView ↗
07/13/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
07/31/2026Fire-Resistant Penetrations and JointsXiong Wei Wuspecial
07/31/2026Energy Code Compliance InspectionsJaeyoung Jangprogress
07/07/2026Fire-Resistant Penetrations and JointsXiong Wei Wuspecial
07/07/2026Energy Code Compliance InspectionsJaeyoung Jangprogress
07/07/2026Fire-Resistance Rated ConstructionJaeyoung Jangprogress
07/07/2026Lighting in dwelling unitsJaeyoung Jangenergy_progress
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/16/2026B01400797-P3Request digital key ↗
08/16/2026B01400797-P2Request digital key ↗
08/16/2026B01400797-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/16/2026B01400797-P2Open ↗
08/16/2026B01400797-P1Open ↗
08/16/2026B01400797-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/24/2026B01400797-P3Open ↗
08/23/2026B01400797-I1Open ↗
08/23/2026B01400797-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026B01400797-P3Open ↗
08/23/2026B01400797-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/16/2026B01400797-P2Open ↗
08/16/2026B01400797-P1Open ↗
08/16/2026B01400797-S1Open ↗
Showing 3 of 5 on file for this type