← Back
Professional building / stand-alone funeral home
1273 CONEY ISLAND AVENUE
BROOKLYN · BIN 3179493
💬 Discuss this project
1984Year Built
1Stories
O7Building Class
R5Zoning
6,000 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Professional building / stand-alone funeral home · Owner of record: 1273 CONEY ISLAND AVENUE LLC · 6,000 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Floor 112p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
1273 CONEY ISLAND AVE2004/09/2026
PM PEDIATRICS REALTY-MIDWOOD303/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DRAFT MASTER ENGINEERING PC403/02/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CHAMPION MECHANICAL INCGeneral Contractor104/08/2026
GREGG NY PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RYAN SPECIAL ENGINEERING2018303/02/2026
Building Lifecycle
All (84)Filed (4)Permit Issued (2)Violation (5)Inspection (8)Objection (50)Special Inspection (15)
04/08/2026
Objection raised — Electrical
04/08/2026
Objection resolved — Addressed
04/03/2026
Objection resolved — Addressed
04/03/2026
Objection resolved — Addressed
04/03/2026
Objection resolved — Addressed
04/03/2026
Objection resolved — Addressed
04/03/2026
Objection resolved — Addressed
04/03/2026
Objection resolved — Addressed
03/27/2026
Objection resolved — Addressed
03/27/2026
Objection resolved — Addressed
03/27/2026
Objection resolved — Addressed
03/27/2026
Objection resolved — Addressed
03/04/2026
Objection raised — Other
03/04/2026
Objection raised — Other
03/04/2026
Objection raised — Other
03/04/2026
Objection raised — Other
03/04/2026
Objection raised — Admin
03/04/2026
Objection raised — Other
03/04/2026
Objection raised — Other
03/04/2026
Objection raised — Other
03/04/2026
Objection raised — Other
03/04/2026
Objection raised — Fire_Protection
03/04/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
William Ryan
03/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Ryan
03/04/2026
Special inspection requirement — Sprinkler Systems
William Ryan
03/02/2026
Filed — Alteration CO
INSTALLATION OF PLUMBING FIXTURES, INSTALLATION OF COMMERICAL COOKING EQUIPMENT AND MODIFICATION TO EXISTING SPRINKER SYSTEM
B01228685-P3
03/02/2026
Filed — No Work
B01244356-I1
02/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Ryan
02/06/2026
Special inspection requirement — Sprinkler Systems
William Ryan
02/06/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
William Ryan
12/18/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/18/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/24/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/03/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/15/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/10/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/07/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/22/2025
Permit issued — Plumbing
B01228685-S1-PL
09/17/2025
Objection resolved — Addressed
08/26/2025
Permit issued — Mechanical Systems
B01228685-I1-MS
08/14/2025
Objection resolved — Addressed
08/04/2025
Objection raised — Energy
08/01/2025
Objection resolved — Addressed
08/01/2025
Objection resolved — Addressed
08/01/2025
Objection resolved — Addressed
08/01/2025
Objection resolved — Addressed
08/01/2025
Objection resolved — Addressed
08/01/2025
Objection resolved — Addressed
08/01/2025
Objection resolved — Addressed
08/01/2025
Objection resolved — Addressed
07/23/2025
Objection raised — Fire_Protection
07/23/2025
Objection raised — Fire_Protection
07/23/2025
Objection raised — Admin
07/16/2025
Objection raised — Mechanical
07/01/2025
Objection resolved — Addressed
07/01/2025
Objection resolved — Addressed
07/01/2025
Objection resolved — Addressed
07/01/2025
Objection resolved — Addressed
06/30/2025
Objection raised — Admin
Latest 60 of 84 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedGREGG NY PLUMBING, INC09/22/2025
DOB NOWMechanical SystemsPermit IssuedCHAMPION MECHANICAL08/26/2025
BIS—ISSUEDSIGNSTAR NYC02/27/2015
BIS—ISSUEDSIGNSTAR NYC02/27/2015
BIS—ISSUEDSIGNSTAR NYC02/27/2015
BISSPISSUEDJ. CAIAZZO PLBG & HTG CORP01/05/2015
BISPLISSUEDDONATO, INC11/17/2014
BISMHISSUEDAMBROSINO CONSULTANT CORP11/14/2014
BIS—ISSUEDAMBROSINO CONSULTANT CORP11/14/2014
BISEQISSUEDAMBROSINO CONSULTANT CORP11/14/2014
BISMHISSUEDARISTA AIR CONDITIONING CORP06/23/2003
1 project · most recent 03/02/2026
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/02/2026Permit IssuedCHAMPION MECHANICAL INCVentilation Systems
Ventilation
Captiveaire DU180HFA 3,750 CFM · Kitchen Exhaust ×2
Canarm BI-20RM 4,800 CFM · Kitchen Exhaust ×1
1 project · most recent 03/02/2026
FiledStatusContractorScope
03/02/2026——26 heads
1 project · most recent 03/02/2026
Gas Water/Sanitary
FiledStatusContractorScope
03/02/2026Permit IssuedGREGG NY PLUMBING, INCGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
12/18/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/18/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/24/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/03/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
10/15/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/10/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/07/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
03/04/2026HVAC-R and service water piping design and insulationWilliam Ryanenergy_progress
03/04/2026Fire-Resistant Penetrations and JointsWilliam Ryanspecial
03/04/2026Sprinkler SystemsWilliam Ryanspecial
02/06/2026Fire-Resistant Penetrations and JointsWilliam Ryanspecial
02/06/2026Sprinkler SystemsWilliam Ryanspecial
02/06/2026HVAC-R and service water piping design and insulationWilliam Ryanenergy_progress
06/20/2025Energy Code Compliance InspectionsWilliam Ryanprogress
06/20/2025Fire-Resistance Rated ConstructionWilliam Ryanprogress
06/20/2025HVAC-R and service water piping design and insulationWilliam Ryanenergy_progress
06/20/2025HVAC-R and service water heating system controlsWilliam Ryanenergy_progress
06/20/2025HVAC-R and service water heating equipmentWilliam Ryanenergy_progress
06/20/2025Maintenance informationWilliam Ryanenergy_progress
06/20/2025Fire-Resistant Penetrations and JointsWilliam Ryanspecial
05/20/2025Mechanical SystemsWilliam Ryanspecial
05/20/2025FinalWilliam Ryanprogress
▾Documents — 158 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch3
08/18/2026B01228685-P3Request digital key ↗
08/18/2026B01228685-S1Request digital key ↗
08/18/2026B01228685-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Place of Assembly1
08/18/2026B01244356-I1Request digital key ↗
▸Applications & Permits21
▸BISPLAN / WORK APPROVAL APPLICATION13
07/24/2018340184758Open ↗
07/24/2018320461656Open ↗
05/10/2018320914711Open ↗
Showing 3 of 13 on file for this type
▸BISWORK PERMIT APPLICATION7
03/02/2015321086052Open ↗
03/02/2015321085507Open ↗
03/02/2015321085491Open ↗
Showing 3 of 7 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
03/31/2015320914711Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B01228685-I1Open ↗
▸Seals & Professional Certifications42
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION13
07/11/2015340175161Open ↗
07/11/2015340175161Open ↗
05/22/2015321086052Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
09/23/2026B01228685-I1Open ↗
09/23/2026B01228685-I1Open ↗
09/23/2026B01228685-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/23/2026B01228685-I1Open ↗
09/23/2026B01228685-I1Open ↗
09/01/2026B01228685-S1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
02/25/2015321086052Open ↗
02/25/2015321085507Open ↗
02/23/2015321085491Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/18/2026B01228685-I1Open ↗
08/18/2026B01228685-P3Open ↗
08/18/2026B01228685-S1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
02/25/2015321086052Open ↗
02/25/2015321085507Open ↗
02/23/2015321085491Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/29/2014340184758Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
09/29/2014340184758Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
09/15/2014340175161Open ↗
▸Trade Schedules & Equipment10
▸BISSCHEDULE B - PLUMBING3
06/09/2015340175161Open ↗
05/27/2015340175161Open ↗
09/19/2014340175161Open ↗
▸BISRPZ/DDCV TEST REPORT : GEN215B3
08/14/2015340175161Open ↗
08/14/2015340175161Open ↗
08/14/2015340175161Open ↗
▸BISSELF-CERT PLUMBING NOTICE3
08/14/2015340175161Open ↗
04/09/2015340175161Open ↗
03/20/2015340175161Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
05/29/2015321094105Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST2
04/16/2015320914711Open ↗
11/05/2014320914711Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026B01228685-I1Open ↗
▸Environmental & Asbestos10
▸BISASBESTOS: CERTIFICATION (DEP ACP5)7
02/25/2015321086052Open ↗
02/25/2015321085507Open ↗
02/23/2015321085491Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/18/2026B01228685-P3Open ↗
08/18/2026B01228685-S1Open ↗
08/18/2026B01228685-I1Open ↗
▸Energy Compliance12
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
07/11/2015340175161Open ↗
07/11/2015340175161Open ↗
04/01/2015320914711Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
10/03/2014340175161Open ↗
09/30/2014340175161Open ↗
09/22/2014340175161Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
09/28/2018321094105Open ↗
07/11/2015340175161Open ↗
04/16/2015320914711Open ↗
▸Inspections & Test Reports8
▸BISTECHNICAL REPORT: RESPONSIBILITY5
11/05/2014320914711Open ↗
10/08/2014320914711Open ↗
09/29/2014340184758Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
07/08/2015320914711Open ↗
11/17/2014320914711Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
11/17/2014320914711Open ↗
▸Approvals, Objections & Sign-offs14
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST8
09/28/2018321094105Open ↗
08/31/2018321094105Open ↗
08/04/2015320914711Open ↗
Showing 3 of 8 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
02/25/2015321086052Open ↗
02/25/2015321085507Open ↗
02/23/2015321085491Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE2
09/22/2014320914711Open ↗
04/18/2012320461656Open ↗
▸Cost, Insurance & Ownership14
▸BISCOST AFFIDAVIT14
09/28/2018321094105Open ↗
07/11/2015340175161Open ↗
07/08/2015320914711Open ↗
Showing 3 of 14 on file for this type
▸Filing & Intake Forms16
▸BISEFILING COVER SHEET5
04/02/2015321094105Open ↗
02/25/2015321086052Open ↗
02/25/2015321085507Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION5
06/09/2015340175161Open ↗
04/16/2015320914711Open ↗
11/05/2014320914711Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM4
09/28/2018321094105Open ↗
08/31/2018321094105Open ↗
07/24/2018340184758Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
09/29/2014340184758Open ↗
09/19/2014340175161Open ↗
▸Other Documents3
▸BISPLOT DIAGRAM1
10/08/2014320914711Open ↗
▸DOB NOWProperty Ownership Certification1
08/18/2026B01228685-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026B01228685-I1Open ↗