← Back
Three families
1936 WEST 11 STREET
BROOKLYN · BIN 3189799
💬 Discuss this project
1930Year Built
2Stories
C0Building Class
R4-1Zoning
2,480 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Three families · 2,500 sf lot · 0.99 FAR built · Flood zone X500
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HOME604/09/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SHENKER ARCHITECT, PC301/28/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Shenker Architects303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ROBKE PLUS INCGeneral Contractor203/21/2026
ALTAIR PLUMBING AND HEATPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHENKER ARCHITECT, PC756301/28/2026
Building Lifecycle
All (29)Filed (3)Permit Issued (2)Signed Off (2)Violation (5)Inspection (5)Objection (8)Special Inspection (4)
06/26/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
05/13/2026
Signed off — Alteration
Remove and cap plumbing fixtures in conjunction with GC application #B01304220-I1 and correct ECB violation #39162290M.
B01304220-S1
05/13/2026
Signed off — Alteration
Remove and cap plumbing fixtures in conjunction with GC application #B01304220-I1 and correct ECB violation #39162290M.
B01304220-I1
03/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
DMITRIY SHENKER
02/26/2026
Objection resolved — Addressed
02/04/2026
Objection raised — Plumbing
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection raised — Plumbing
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection raised — Cost
01/28/2026
Filed — Alteration
Remove and cap plumbing fixtures in conjunction with GC application #B01304220-I1 and correct ECB violation #39162290M.
B01304220-P1
01/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
DMITRIY SHENKER
01/20/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/07/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/22/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/02/2025
Permit issued — Plumbing
B01304220-S1-PL
12/02/2025
Permit issued — General Construction
B01304220-I1-GC
11/20/2025
Objection resolved — Addressed
11/06/2025
Objection raised — Scope
10/23/2025
Filed — Alteration
Remove and cap plumbing fixtures in conjunction with GC application #B01304220-I1 and correct ECB violation #39162290M.
B01304220-S1
10/23/2025
Filed — Alteration
Remove and cap plumbing fixtures in conjunction with GC application #B01304220-I1 and correct ECB violation #39162290M.
B01304220-I1
10/17/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
DMITRIY SHENKER
10/17/2025
Special inspection requirement — Final
DMITRIY SHENKER
10/02/2025
Violation issued (ECB, closed)
Construction
10/02/2025
Violation issued (ECB, closed)
Construction
10/02/2025
Violation issued (ECB, closed)
Construction
08/21/2025
Violation issued (ECB, closed)
Construction
03/02/2022
Violation issued (HPD, closed)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offALTAIR PLUMBING AND HEAT12/02/2025
DOB NOWGeneral ConstructionSigned-offROBKE PLUS INC12/02/2025
1 project · most recent 01/28/2026
Gas Water/Sanitary
FiledStatusContractorScope
01/28/2026Signed-offALTAIR PLUMBING AND HEATGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
06/26/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
03/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/20/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/07/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/22/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
03/02/2026Fire-Resistant Penetrations and JointsDMITRIY SHENKERspecial
01/27/2026Fire-Resistant Penetrations and JointsDMITRIY SHENKERspecial
10/17/2025Fire-Resistant Penetrations and JointsDMITRIY SHENKERspecial
10/17/2025FinalDMITRIY SHENKERprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/20/2026B01304220-S1Request digital key ↗
08/20/2026B01304220-I1Request digital key ↗
08/20/2026B01304220-P1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/20/2026B01304220-S1Open ↗
08/20/2026B01304220-I1Open ↗
08/20/2026B01304220-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
08/27/2026B01304220-I1Open ↗
08/25/2026B01304220-P1Open ↗
08/23/2026B01304220-S1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/27/2026B01304220-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/20/2026B01304220-P1Open ↗
08/20/2026B01304220-I1Open ↗
08/20/2026B01304220-S1Open ↗