City residence, one family
2073 EAST 1 STREET
BROOKLYN · BIN 3191657
💬 Discuss this project
1925Year Built
2.75Stories
A4Building Class
R3-1Zoning
3,066 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
City residence, one family · 2,325 sf lot · 1.32 FAR built · Flood zone X
Locations of Work
StructuralPlumbing
Roof1p · 1 filing · 3 docs
Floor 28p · 1 filing · 10 docs
Floor 17p · 1 filing · 10 docs
Cellar10p · 2 filings · 13 docs
1 job · most recent 01/30/2023
Gas Water/Sanitary
FiledStatusContractorScope
01/30/2023Permit IssuedMELONIK PLBG & HTG CORPGas, Water/Sanitary
1 job · most recent 08/12/2021
Wood
FiledStatusContractorScope
08/12/2021——Wood
Building Lifecycle
All (28)Filed (4)Permit Issued (2)Violation (3)Inspection (8)Objection (4)Special Inspection (7)
03/23/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/06/2026
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
04/30/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/02/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/30/2023
Filed — Alteration
FILING FOR PLUMBING WORK APPLICATION #B00338300-I1 IN CONJUNCTION TO ALT 2 #322044649
B00574872-P1
12/28/2022
Special inspection requirement — HVAC-R and service water heating equipment
ALBERTO ROMAN
12/28/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
ALBERTO ROMAN
12/28/2022
Special inspection requirement — Maintenance information
ALBERTO ROMAN
12/28/2022
Special inspection requirement — HVAC-R and service water heating system controls
ALBERTO ROMAN
10/03/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/16/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/28/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/28/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/03/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/03/2022
Permit issued — Plumbing
B00574872-I1-PL
02/23/2022
Filed — Alteration
FILING FOR PLUMBING WORK APPLICATION #B00338300-I1 IN CONJUNCTION TO ALT 2 #322044649
B00574872-I1
08/15/2021
Objection raised — Other
08/15/2021
Objection resolved — Addressed
08/15/2021
Objection raised — Other
08/15/2021
Objection raised — Other
08/12/2021
Filed — Alteration
Structural design for 2 stories horizontal extension to existing 2 story frame building.
B00575545-I1
08/11/2021
Special inspection requirement — Final
08/11/2021
Special inspection requirement — Structural Wood Frame
08/11/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/09/2021
Permit issued — Construction Fence
B00516849-I1-FN
05/06/2021
Filed — Alteration
B00516849-I1
06/20/2017
Violation issued (ECB, closed)
Construction
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/14/2014$850K—Private party → Private party$277/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
REAL ENGINEERING INC.201/30/2023
DOKA ENGINEERING PC108/12/2021
DAVID SILBERMAN, P.E.105/06/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MISTER EXPEDITER203/21/2026
ACDE GROUP103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NESS MECHANICAL P & H INCPlumbing607/08/2026
ATTILIO DEVELOPERS CORPGeneral Contractor107/08/2026
MELONIK PLBG HTGGeneral Contractor103/22/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedNESS MECHANICAL P & H INC03/03/2022
DOB NOWConstruction FencePermit IssuedATTILIO DEVELOPERS06/09/2021
BISOTISSUEDATTILIO DEVELOPERS CORP07/12/2022
BISOTISSUEDATTILIO DEVELOPERS CORP06/23/2021
BISOTISSUEDATTILIO DEVELOPERS CORP06/23/2021
BISOTRE-ISSUEDVICE CONTACTING LLC04/17/2018
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
03/23/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/06/2026Fail-Final CND-Occupancy InspectionFailView ↗
04/30/2024Pass-Final CND-Occupancy InspectionPassView ↗
02/02/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/03/2022Pass-Final CND-Occupancy InspectionPassView ↗
09/16/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/03/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
12/28/2022HVAC-R and service water heating equipmentALBERTO ROMANenergy_progress
12/28/2022HVAC-R and service water piping design and insulationALBERTO ROMANenergy_progress
12/28/2022Maintenance informationALBERTO ROMANenergy_progress
12/28/2022HVAC-R and service water heating system controlsALBERTO ROMANenergy_progress
08/11/2021Final—progress
08/11/2021Structural Wood Frame—progress
08/11/2021Structural Stability – Alterations of existing buildings—special
▾Documents — 81 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/01/2026B00516849-I1Request digital key ↗
08/27/2026B00574872-P1Request digital key ↗
08/27/2026B00574872-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits19
▸BISPLAN / WORK APPROVAL APPLICATION10
09/30/2022322044649Open ↗
09/02/2021322044649Open ↗
04/29/2020322044649Open ↗
Showing 3 of 10 on file for this type
▸BISWORK PERMIT APPLICATION6
06/24/2021322044649Open ↗
06/24/2021322044649Open ↗
04/19/2018340528539Open ↗
Showing 3 of 6 on file for this type
▸BISPARTIAL DEMO PLAN & DS1 (FOR AL/EW-OT PERMITS)1
06/17/2021322044649Open ↗
▸BISPARTIAL DEMO: 10-DAY NOTICE (FOR AL/EW-OT PERMITS)1
09/30/2022322044649Open ↗
▸BISTEMPORARY FENCE APPLICATION & PERMIT1
09/30/2022322044649Open ↗
▸Zoning, Tax Lot & Property Records2
▸BISZONING EXHIBIT I: CERTIFICATION1
04/07/2020322044649Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
04/07/2020322044649Open ↗
▸Seals & Professional Certifications15
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
03/18/2020322044649Open ↗
01/24/2020322030342Open ↗
07/01/2019340528539Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/01/2026B00516849-I1Open ↗
09/01/2026B00575545-I1Open ↗
08/27/2026B00574872-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/26/2026B00574872-P1Open ↗
08/26/2026B00574872-P1Open ↗
08/26/2026B00574872-P1Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
08/15/2017340528539Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/15/2017340528539Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/15/2017340528539Open ↗
▸Safety & Tenant Protection7
▸BISSTREET TREE CHECKLIST6
05/06/2020322044649Open ↗
05/05/2020322044649Open ↗
04/29/2020322044649Open ↗
Showing 3 of 6 on file for this type
▸BISTenant Protection Plan and Notes1
03/18/2020322044649Open ↗
▸Environmental & Asbestos7
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
05/06/2020322044649Open ↗
05/05/2020322044649Open ↗
03/18/2020322044649Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/27/2026B00574872-P1Open ↗
08/27/2026B00574872-I1Open ↗
08/15/2026B00575545-I1Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
03/18/2020322044649Open ↗
01/24/2020322030342Open ↗
12/29/2017340528539Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
06/17/2021322044649Open ↗
08/15/2017340528539Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
08/15/2017340528539Open ↗
▸Inspections & Test Reports9
▸BISTECHNICAL REPORT: RESPONSIBILITY5
06/17/2021322044649Open ↗
04/07/2020322044649Open ↗
08/15/2017340528539Open ↗
Showing 3 of 5 on file for this type
▸BISSOIL REPORT2
07/01/2019340528539Open ↗
08/15/2017340528539Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION2
04/07/2020322044649Open ↗
08/15/2017340528539Open ↗
▸Approvals, Objections & Sign-offs2
▸BISSCHEDULE A - OCCUPANCY / USE1
01/24/2020322030342Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM (SIGNOFF)1
05/06/2020322044649Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT3
03/18/2020322044649Open ↗
01/24/2020322030342Open ↗
08/15/2017340528539Open ↗
▸BISCIVIL PENALTY AFFADAVIT/REQUEST1
04/17/2018340528539Open ↗
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET3
05/07/2020322044649Open ↗
03/18/2020322044649Open ↗
01/24/2020322030342Open ↗
▸BISBOROUGH INTAKE FORM2
04/09/2020322044649Open ↗
04/01/2020322044649Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
08/15/2017340528539Open ↗