← Back
Fire Department
901 AVENUE U
BROOKLYN · BIN 3192210
💬 Discuss this project
1931Year Built
2Stories
Y1Building Class
R6AZoning
6,120 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
Fire Department · Owner of record: FIRE DEPARTMENT OF NEW YORK · 4,400 sf lot · 1.39 FAR built · Flood zone X500
Locations of Work
StructuralMechanicalPlumbingGeneral
Roof3p · 2 filings · 12 docs
Floor 16p · 5 filings · 20 docs
Cellar5p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FDNY603/22/2026
J & G GNRL CONTRACT INC103/21/2026
CITY OF NY FIRE DEPARTMENT303/21/2026
NYC DEPT OF GENERAL SERVICES103/21/2026
DIV OF DESIGN CONSTRUCTION MGT203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AYALA ENGINEERING PC111/25/2024
CAMERON ENGINEERING303/12/2024
LIRO ENGINEERS, INC.102/04/2022
BKH ARCHITECT, PLLC112/20/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
P WOLFE CONSULTANTS203/21/2026
NOEL BUILDING CONSULTING INC603/21/2026
SUN103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ZHL GROUP INCGeneral Contractor203/21/2026
IRVING BAPTISTEElectrical103/21/2026
METRO ENVIRONMENTAL SRVCSGeneral Contractor107/08/2026
PASQUALE QUARATINO INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AYALA ENGINEERING P.C.9207111/25/2024
TECTONIC ENGINEERING CONS106102/04/2022
Building Lifecycle
All (54)Filed (6)Permit Issued (3)Signed Off (2)Violation (8)Inspection (3)Objection (16)Special Inspection (16)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/04/2024
Permit issued — Mechanical Systems
B01082716-I1-MS
11/25/2024
Filed — Alteration
ALTERATION TYPE 2 APPLICATION FILED FOR INSTALLATION COMMERCIAL KITCHEN HOOD AND FIRE SUPPRESSION SYSTEM. NO CHANGE OF USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01082716-I1
07/30/2024
Objection resolved — Addressed
07/18/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Pablo Ayala
07/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Pablo Ayala
07/18/2024
Special inspection requirement — Final
Pablo Ayala
07/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Pablo Ayala
07/18/2024
Special inspection requirement — Mechanical Systems
Pablo Ayala
07/03/2024
Signed off — Alteration
EMPTY, PURGE, CLEAN, REMOVE & DISPOSE OF ONE (1) 550-GAL BIO DIESEL AST, (1)FUEL DISPENSER & VEEDER ROOT. INSTALL IN-KIND (1) 550-GAL FIELD FABRICATED SINGLE-WALL BIO DIESEL AST, (1)FUEL DISPENSERS, CONCRETE ISLAND, VEEDER ROOT TLS-450 AS PER PLANS.
B00639785-I1
04/30/2024
Objection raised — Scope
04/30/2024
Objection resolved — Addressed
04/24/2024
Objection resolved — Addressed
04/24/2024
Objection resolved — Addressed
04/24/2024
Objection resolved — Addressed
04/24/2024
Objection resolved — Addressed
04/23/2024
Objection resolved — Addressed
04/23/2024
Objection resolved — Addressed
03/26/2024
Objection raised — Scope
03/26/2024
Objection raised — Scope
03/26/2024
Objection raised — Scope
03/19/2024
Objection raised — Inspections
03/19/2024
Objection raised — Other
03/19/2024
Objection raised — Scope
03/19/2024
Objection raised — Other
03/12/2024
Filed — Alteration
B00979507-I1
03/11/2024
Filed — Alteration
Installation of new gas generator and gas booster pump for Fire house EC 254. No change of use, egress or occupancy under this application.
B00979479-I1
03/11/2024
Filed — Alteration
Installation of emergency gas-fired generator with exhaust piping. No change of use, egress, or occupancy under this application
B00979472-I1
03/11/2024
Special inspection requirement — Structural Steel - Details
01/16/2024
Violation issued (FDNY_ORDER, closed)
01/16/2024
Violation issued (FDNY_ORDER, closed)
12/19/2023
Special inspection requirement — Final
12/19/2023
Special inspection requirement — Mechanical Systems
12/19/2023
Special inspection requirement — Chimneys and vents
12/19/2023
Special inspection requirement — Emergency and Standby Power Systems (Generator)
12/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
12/19/2023
Special inspection requirement — Final
12/19/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/19/2023
Permit issued — General Construction
B00639785-I1-GC
09/09/2022
Signed off — Alteration
PROPOSED (1) SPRINKLER HEAD OFF THE DOMESTIC WATER LINE IN THE CELLAR TO PROTECT SOLAR PANEL BATTERY STORAGE
B00645558-I1
04/11/2022
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
03/30/2022
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
03/30/2022
Inspection — Certified Sprinkler (PL) - SP - Roughing
Certified
View inspection ↗
02/04/2022
Filed — Alteration
EMPTY, PURGE, CLEAN, REMOVE & DISPOSE OF ONE (1) 550-GAL BIO DIESEL AST, (1)FUEL DISPENSER & VEEDER ROOT. INSTALL IN-KIND (1) 550-GAL FIELD FABRICATED SINGLE-WALL BIO DIESEL AST, (1)FUEL DISPENSERS, CONCRETE ISLAND, VEEDER ROOT TLS-450 AS PER PLANS.
B00639785-I1
12/28/2021
Permit issued — Plumbing
B00645558-I1-PL
12/20/2021
Filed — Alteration
PROPOSED (1) SPRINKLER HEAD OFF THE DOMESTIC WATER LINE IN THE CELLAR TO PROTECT SOLAR PANEL BATTERY STORAGE
B00645558-I1
12/01/2021
Special inspection requirement — Energy Code Compliance Inspections
GEORGE GHEBRYAL
12/01/2021
Special inspection requirement — Final
GEORGE GHEBRYAL
12/01/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedZHL GROUP INC12/04/2024
DOB NOWGeneral ConstructionSigned-offMETRO ENVIRONMENTAL SRVCS07/19/2023
DOB NOWPlumbingSigned-offPASQUALE QUARATINO INC12/28/2021
BISOTISSUEDRDS INDUSTRIES INC09/24/2021
BISEQISSUEDJ & G GNRL CONTRACT INC05/31/2013
BISMHISSUEDZHL GROUP INC09/23/2009
BISOTISSUEDZHL GROUP INC09/23/2009
BISBLISSUEDMETROPOLITAN HEAT & POWER CO01/27/2006
BISPLISSUEDMETROPOLITAN HEAT & POWER CO01/27/2006
BISPLISSUEDZ.W. PLBG & HTG CORP03/09/1998
BISOTISSUEDTECH-BUILDERS INC.08/08/1997
BISEQISSUEDFOUNDATION CONSTRUCTION CONSULT.11/01/1996
BISOTISSUEDFOUNDATION CONSTRUCTION CONSULT.11/01/1996
BISOTISSUEDTECH-BUILDERS INC.07/27/1994
BISPLISSUEDACE CONTR. CORP04/19/1994
BISOTISSUEDTECH-BUILDERS INC.04/01/1994
BISBLISSUEDCENTRAL ABSORPTION INC.01/06/1993
BISPLISSUEDDUNDEE PLUMBING01/06/1993
1 project · most recent 03/11/2024
Generators
FiledStatusContractorScopeMake / Model / Capacity
03/11/2024——Generators
Generators
Cummins C80N6 Generator ×1
1 project · most recent 03/11/2024
Gas
FiledStatusContractorScope
03/11/2024——Gas
3 projects · most recent 09/25/2026
General Wiring
FiledStatusContractorScope
09/25/2026Permit IssuedPOLARIS ELEC'L CONST CORPGeneral Wiring
12/19/2023CompleteFVC ELECTRIC, INCGeneral Wiring
12/16/2020CompleteRDS ELECTRIC CO., INCGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
04/11/2022Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
03/30/2022Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
03/30/2022Certified Sprinkler (PL) - SP - RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
07/18/2024HVAC-R and service water piping design and insulationPablo Ayalaenergy_progress
07/18/2024Energy Code Compliance InspectionsPablo Ayalaprogress
07/18/2024FinalPablo Ayalaprogress
07/18/2024Fire-Resistant Penetrations and JointsPablo Ayalaspecial
07/18/2024Mechanical SystemsPablo Ayalaspecial
03/11/2024Structural Steel - Details—special
12/19/2023Final—progress
12/19/2023Mechanical Systems—special
12/19/2023Chimneys and vents—special
12/19/2023Emergency and Standby Power Systems (Generator)—special
12/19/2023Fire-Resistant Penetrations and Joints—special
12/19/2023Final—progress
12/19/2023Structural Stability – Alterations of existing buildings—special
12/01/2021Energy Code Compliance InspectionsGEORGE GHEBRYALprogress
12/01/2021FinalGEORGE GHEBRYALprogress
12/01/2021Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
▾Documents — 85 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/31/2026B00645558-I1Request digital key ↗
08/31/2026B00639785-I1Request digital key ↗
08/25/2026B00979472-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits11
▸BISPLAN / WORK APPROVAL APPLICATION6
09/15/2021340799336Open ↗
06/03/2013320863810Open ↗
03/04/2011310304667Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION5
09/24/2021340799336Open ↗
06/03/2013320863810Open ↗
09/24/2009310304667Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications20
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/31/2026B00645558-I1Open ↗
08/25/2026B00979479-I1Open ↗
08/23/2026B01082716-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
06/03/2013320863810Open ↗
05/31/2011310304667Open ↗
05/31/2011310304667Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026B01082716-I1Open ↗
09/01/2026B01082716-I1Open ↗
08/24/2026B00639785-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B01082716-I1Open ↗
08/24/2026B00639785-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/15/2021340799336Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/03/2013320863810Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/15/2021340799336Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
09/15/2021340799336Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
03/13/2009310304667Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
09/15/2021340799336Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/31/2026B00645558-I1Open ↗
08/25/2026B00979479-I1Open ↗
08/23/2026B01082716-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
03/13/2009310304667Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/15/2021340799336Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
01/12/2023340799336Open ↗
09/24/2021340799336Open ↗
09/15/2021340799336Open ↗
▸BISNYCECC ANALYSIS1
09/15/2021340799336Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
09/15/2021340799336Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
01/12/2023340799336Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
01/12/2023340799336Open ↗
09/24/2021340799336Open ↗
09/15/2021340799336Open ↗
▸Approvals, Objections & Sign-offs17
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter6
08/31/2026B00645558-I1Open ↗
08/13/2026B00979479-I1Open ↗
08/13/2026B01082716-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)4
08/13/2026B00979479-I1Open ↗
08/13/2026B00639785-I1Open ↗
08/13/2026B00979507-I1Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
01/13/2023340799336Open ↗
05/31/2011310304667Open ↗
05/24/2011310304667Open ↗
▸BISDESIGN COMM. APPROVAL: CITY-OWNED PROPERTY (EXTERIOR WORK)1
09/15/2021340799336Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
03/13/2009310304667Open ↗
▸BISDESIGN COMM. SIGNOFF: CITY-OWNED PROPERTY (EXTERIOR WORK)1
01/12/2023340799336Open ↗
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)1
08/13/2026B00639785-I1Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT4
09/15/2021340799336Open ↗
05/24/2011310304667Open ↗
03/13/2009310304667Open ↗
Showing 3 of 4 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
01/12/2023340799336Open ↗
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET3
06/03/2013320863810Open ↗
03/13/2009310304667Open ↗
03/13/2009310304667Open ↗
▸BISADDITIONAL INFORMATION2
03/04/2011310304667Open ↗
03/05/2010310304667Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
09/15/2021340799336Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
09/15/2021340799336Open ↗