← Back
Primarily 2 family with 1 store or office
2113 WEST 6 STREET
BROOKLYN · Gravesend (East)-Homecrest · BIN 3192576
💬 Discuss this project
1931Year Built
3Stories
S2Building Class
R5Zoning
4,788 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: MIN HOA 2113 LLC · 1,715 sf lot · 2.79 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbing
Floor 16p · 2 filings · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MIN HOA 2113 LLC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KL INNOVATIVE DESIGN INC304/28/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BASIC GROUPS603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CUBE BUILDERS GROUP NYGeneral Contractor107/08/2026
PIPESTYLISTS, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NY ACOM ENGINEERING PLLC7061104/28/2022
NIC 88 CORP8371106/11/2021
Building Lifecycle
All (15)Filed (3)Permit Issued (2)Signed Off (2)Violation (1)Inspection (2)Special Inspection (5)
11/04/2022
Signed off — Alteration
B00538729-I1
05/31/2022
Signed off — Alteration
B00538725-I1
05/02/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/02/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/29/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
04/29/2022
Special inspection requirement — Final
Eric Sun
04/29/2022
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
04/29/2022
Special inspection requirement — Interior lighting power
Eric Sun
04/29/2022
Special inspection requirement — Metering
Eric Sun
04/28/2022
Filed — Alteration
B00538729-P1
06/15/2021
Permit issued — General Construction
B00538729-I1-GC
06/14/2021
Permit issued — Plumbing
B00538725-I1-PL
06/11/2021
Filed — Alteration
B00538729-I1
06/11/2021
Filed — Alteration
B00538725-I1
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offCUBE BUILDERS GROUP NY06/15/2021
DOB NOWPlumbingSigned-offT & T PLUMBING INC06/14/2021
BISEQISSUEDR & J CONSTRUCTION CORP08/15/2000
BIS—ISSUEDR & J CONSTRUCTION CORP08/15/2000
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
05/02/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/02/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/29/2022Fire-Resistant Penetrations and JointsEric Sunspecial
04/29/2022FinalEric Sunprogress
04/29/2022Energy Code Compliance InspectionsEric Sunprogress
04/29/2022Interior lighting powerEric Sunenergy_progress
04/29/2022MeteringEric Sunenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
09/01/2026B00538729-P1Request digital key ↗
09/01/2026B00538729-I1Request digital key ↗
09/01/2026B00538725-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
08/22/2026B00538729-I1Open ↗
08/22/2026B00538729-I1Open ↗
08/22/2026B00538729-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/01/2026B00538729-P1Open ↗
09/01/2026B00538729-I1Open ↗
09/01/2026B00538725-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026B00538729-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00538729-I1Open ↗