← Back
Miscellaneous one family
1122 AVENUE S
BROOKLYN · BIN 3196601
💬 Discuss this project
1930Year Built
2Stories
A9Building Class
R4-1Zoning
1,392 sfGross Floor Area
1Units
3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
Miscellaneous one family · 2,350 sf lot · 0.59 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHANDA ENGINEERING CONSULTANT PC207/17/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
IKSA GROUP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MKSSKR CONSULTING SERVICEGeneral Contractor107/08/2026
NESPO LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AZ PROFESSIONAL ENGINEERI766107/17/2024
Building Lifecycle
All (47)Filed (2)Permit Issued (2)Violation (12)Objection (22)Special Inspection (9)
03/19/2026
Violation issued (ECB, closed)
Construction
03/10/2026
Permit issued — General Construction
B01023372-I1-GC
03/04/2026
Permit issued — Construction Fence
B00908210-I1-FN
01/12/2026
Violation issued (ECB, closed)
Construction
11/18/2025
Objection resolved — Addressed
11/03/2025
Objection raised — Cost
10/28/2025
Objection resolved — Addressed
10/28/2025
Special inspection requirement — Air barrier - visual inspection
VIJAY KUMAR
10/28/2025
Special inspection requirement — Insulation placement and R values
VIJAY KUMAR
10/28/2025
Special inspection requirement — Interior lighting power
VIJAY KUMAR
10/28/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
VIJAY KUMAR
10/27/2025
Special inspection requirement — Masonry
VIJAY KUMAR
10/27/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
VIJAY KUMAR
07/30/2024
Objection raised — Scope
07/17/2024
Filed — Alteration
B01023372-I1
07/02/2024
Special inspection requirement — Fire-Resistance Rated Construction
VIJAY KUMAR
07/02/2024
Special inspection requirement — Energy Code Compliance Inspections
VIJAY KUMAR
07/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
VIJAY KUMAR
11/30/2023
Violation issued (ECB, closed)
Construction
10/11/2023
Violation issued (ECB, open)
Construction
09/08/2023
Objection raised — Inspections
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Scope
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Structural
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Structural
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Inspections
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Mechanical
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Other
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Inspections
09/08/2023
Objection resolved — Addressed
09/08/2023
Objection raised — Scope
09/08/2023
Objection resolved — Addressed
09/05/2023
Filed — Alteration
B00908210-I1
07/06/2023
Violation issued (ECB, closed)
Construction
06/29/2023
Violation issued (ECB, closed)
Construction
06/29/2023
Violation issued (ECB, closed)
Construction
06/29/2023
Violation issued (ECB, closed)
Construction
06/29/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/29/2023
Violation issued (ECB, closed)
Construction
06/29/2023
Violation issued (ECB, closed)
Construction
06/28/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedNESPO LLC03/10/2026
DOB NOWConstruction FencePermit IssuedMKSSKR CONSULTING SERVICE03/04/2026
1 project · most recent 06/28/2023
General Wiring
FiledStatusContractorScope
06/28/2023Permit IssuedACCURATE ELEC'L CORP.General Wiring
1 project · most recent 09/05/2023
Fence
FiledStatusContractorScope
09/05/2023Permit IssuedMKSSKR CONSULTING SERVICEFence
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
10/28/2025Air barrier - visual inspectionVIJAY KUMARenergy_progress
10/28/2025Insulation placement and R valuesVIJAY KUMARenergy_progress
10/28/2025Interior lighting powerVIJAY KUMARenergy_progress
10/28/2025Fenestration and door U-factor and product ratingsVIJAY KUMARenergy_progress
10/27/2025MasonryVIJAY KUMARspecial
10/27/2025Structural Stability – Alterations of existing buildingsVIJAY KUMARspecial
07/02/2024Fire-Resistance Rated ConstructionVIJAY KUMARprogress
07/02/2024Energy Code Compliance InspectionsVIJAY KUMARprogress
07/02/2024Fire-Resistant Penetrations and JointsVIJAY KUMARspecial
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/26/2026B00908210-I1Request digital key ↗
08/24/2026B01023372-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B01023372-I1Open ↗
08/13/2026B00908210-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026B01023372-I1Open ↗
08/27/2026B01023372-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026B01023372-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B01023372-I1Open ↗