| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/06/2025 | Permit Issued | ALEF CONSTRUCTION INC | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric MXZ-SM60NAM2-U1 66,000 BTU · Fan Coil Indoor ×2 MXZ-SM36NAM2-U1 41,000 BTU · Heat Pump Outdoor ×1 Daikin 4MXM36AVJU9 34,600 BTU · Heat Pump Outdoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/06/2025 | Permit Issued | AMC PLBG, HTG & CLNG, INC | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/17/2026 | Permit Issued | ACCURATE ELEC'L CORP. | General Wiring |
| 10/29/2025 | Complete | GREEN LIGHT ELECL & MECH | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/06/2025 | Permit Issued | ALEF CONSTRUCTION INC | Steel, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/06/2025 | Permit Issued | ALEF CONSTRUCTION INC | Fence |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 08/23/2024 | $1.6M | — | — → — | $580/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| NY BUILDING ASSOCIATES INC | 1 | 11/17/2025 |
| CHUN ENGINEERING CONSULTANT PLLC | 4 | 05/06/2025 |
| ROBERT SIQECA PE | 1 | 03/28/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| CAVALRY | 12 | 03/21/2026 |
| S R SOLAR DESIGN | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| CAVALRY LLC | General Contractor | 5 | 07/08/2026 |
| ALEF CONSTRUCTION INC | General Contractor | 3 | 04/09/2026 |
| J SYNERGY GREEN INC | General Contractor | 1 | 04/09/2026 |
| AMC PLBG, HTG & CLNG, INC | Plumbing | 1 | 07/01/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| NKM ENGINEERING PLLC | 6244 | 1 | 11/17/2025 |
| CHUN ENGINEERING CONSULTA | 9605 | 5 | 05/06/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | ALEF CONSTRUCTION INC | 02/04/2026 |
| DOB NOW | General Construction | Permit Issued | ALEF CONSTRUCTION INC | 02/03/2026 |
| DOB NOW | Solar | Signed-off | J SYNERGY GREEN | 12/16/2025 |
| DOB NOW | Structural | Permit Issued | ALEF CONSTRUCTION INC | 12/16/2025 |
| DOB NOW | General Construction | Signed-off | CAVALRY LLC | 09/03/2025 |
| DOB NOW | General Construction | Signed-off | CAVALRY LLC | 09/03/2025 |
| DOB NOW | Plumbing | Permit Issued | AMC PLBG, HTG & CLNG, INC | 07/30/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | CAVALRY LLC | 07/29/2025 |
| DOB NOW | Construction Fence | Signed-off | CAVALRY LLC | 07/29/2025 |
| DOB NOW | General Construction | Permit Issued | CAVALRY LLC | 07/17/2025 |
| Date | Type | Result | Report |
|---|---|---|---|
| 02/05/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/05/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 11/05/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 11/05/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 11/05/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 10/07/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 09/22/2025 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 12/11/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 01/26/2023 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 01/26/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 11/04/2025 | Air barrier - visual inspection | NARESH MAHANGU | energy_progress |
| 11/04/2025 | Fire-Resistant Penetrations and Joints | NARESH MAHANGU | special |
| 11/04/2025 | Structural Stability – Alterations of existing buildings | NARESH MAHANGU | special |
| 11/04/2025 | Energy Code Compliance Inspections | NARESH MAHANGU | progress |
| 11/04/2025 | Final | NARESH MAHANGU | progress |
| 05/06/2025 | Structural Stability – Alterations of existing buildings | JAMES CHUN | special |
| 04/30/2025 | Ventilation and air distribution system | JAMES CHUN | energy_progress |
| 04/30/2025 | Shutoff dampers | JAMES CHUN | energy_progress |
| 04/30/2025 | Maintenance information | JAMES CHUN | energy_progress |
| 04/30/2025 | Duct leakage testing, insulation and design | JAMES CHUN | energy_progress |
| 04/30/2025 | HVAC-R and service water heating equipment | JAMES CHUN | energy_progress |
| 04/30/2025 | HVAC-R and service water heating system controls | JAMES CHUN | energy_progress |
| 04/30/2025 | HVAC-R and service water piping design and insulation | JAMES CHUN | energy_progress |
| 04/30/2025 | Smoke Control Systems Testing | JAMES CHUN | special |
| 04/30/2025 | Energy Code Compliance Inspections | JAMES CHUN | progress |
| 04/30/2025 | Fire-Resistance Rated Construction | JAMES CHUN | progress |
| 04/10/2025 | Structural Stability – Alterations of existing buildings | JAMES CHUN | special |
| 03/28/2025 | Protection of exposed foundation insulation | JAMES CHUN | energy_progress |
| 03/28/2025 | Energy Code Compliance Inspections | JAMES CHUN | progress |
| 03/28/2025 | Insulation placement and R values | JAMES CHUN | energy_progress |
| 03/27/2025 | Structural Steel - High Strength Bolting | JAMES CHUN | special |
| 03/27/2025 | Structural Steel - Welding | JAMES CHUN | special |
| 03/27/2025 | Structural Wood Frame | JAMES CHUN | progress |
| 03/27/2025 | Concrete - Cast-In-Place | JAMES CHUN | special |
| 03/27/2025 | Post-installed Anchors | JAMES CHUN | special |