1974Year Built
1Stories
O7Building Class
R5Zoning
23,686 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Professional building / stand-alone funeral home · Owner of record: PROTESTANT DUTCH REFORMED CHURCH OF THE TOWN OF FL · 27,067 sf lot · 0.88 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanical
Roof1p · 1 filing · 3 docs
Floor 12p · 1 filing · 5 docs
Cellar2p · 1 filing · 5 docs
1 job · most recent 01/27/2023
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
01/27/2023Signed-offFERDINAND HUNTAir Conditioning Systems
Cooling
American Standard TCC060F300BC 1 BTU · Condensing Unit ×1
Building Lifecycle
All (78)Filed (2)Permit Issued (1)Violation (16)Objection (53)Special Inspection (6)
07/28/2026
Objection resolved — Resolved
04/16/2026
Objection raised — Scope
04/15/2026
Objection resolved — Resolved
04/15/2026
Objection resolved — Resolved
04/15/2026
Objection resolved — Resolved
04/07/2026
Objection resolved — Resolved
04/07/2026
Objection resolved — Resolved
04/07/2026
Objection resolved — Resolved
04/07/2026
Objection resolved — Resolved
04/07/2026
Objection resolved — Resolved
12/10/2025
Violation issued (FDNY_ORDER, closed)
02/05/2025
Objection raised — Structural
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
01/30/2025
Objection resolved — Addressed
10/07/2024
Objection raised — Zoning
10/07/2024
Objection raised — Zoning
10/07/2024
Objection raised — Zoning
10/07/2024
Objection raised — Fire_Protection
10/07/2024
Objection raised — Accessibility
10/07/2024
Objection raised — Fire_Protection
10/07/2024
Objection raised — Fire_Protection
10/07/2024
Objection raised — Fire_Protection
10/07/2024
Objection raised — Structural
10/07/2024
Objection raised — Mechanical
10/07/2024
Objection raised — Fire_Protection
10/07/2024
Objection raised — Fire_Protection
10/07/2024
Objection raised — Scope
10/07/2024
Objection raised — Scope
10/07/2024
Objection raised — Scope
10/07/2024
Objection raised — Scope
10/07/2024
Objection raised — Scope
10/07/2024
Objection raised — Scope
10/07/2024
Objection raised — Scope
10/07/2024
Objection raised — Zoning
10/07/2024
Objection raised — Zoning
10/07/2024
Objection raised — Zoning
10/07/2024
Objection raised — Scope
10/07/2024
Objection raised — Structural
10/07/2024
Objection raised — Zoning
09/27/2024
Filed — Alteration CO
Installation of sprinkler heads. No change of use, egress or occupancy under this application.
B01008448-I1
05/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/22/2024
Special inspection requirement — Energy Code Compliance Inspections
05/22/2024
Special inspection requirement — Fire-Resistance Rated Construction
05/22/2024
Special inspection requirement — Lighting controls
05/22/2024
Special inspection requirement — Metering
Latest 60 of 78 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FLATLANDS REFORMED CHURCH407/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AKT DESIGNS LLC109/27/2024
WELLS ENGINEERING, PLLC101/27/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NOEL BUILDING CONSULTING INC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FERDINAND HUNTGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WELLS DESIGN & CONSULTING7750101/27/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offFERDINAND HUNT01/31/2023
BISOTISSUEDVANGUARD PLMBG. AND HTG.03/23/1992
BISPLISSUEDVANGUARD PLMBG. AND HTG.03/23/1992
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
05/22/2024Fire-Resistant Penetrations and Joints—special
05/22/2024Energy Code Compliance Inspections—progress
05/22/2024Fire-Resistance Rated Construction—progress
05/22/2024Lighting controls—energy_progress
05/22/2024Metering—energy_progress
05/22/2024Interior lighting power—energy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026B00818805-I1Request digital key ↗
08/24/2026B01008448-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026B01008448-I1Open ↗
08/13/2026B00818805-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B01008448-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/24/2026B01008448-I1Open ↗
08/13/2026B00818805-I1Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/24/2026B01008448-I1Open ↗