← Back
Two family brick
2276 EAST 73 STREET
BROOKLYN · BIN 3237930
💬 Discuss this project
1970Year Built
1Stories
B1Building Class
R3-1Zoning
—Gross Floor Area
2Units
Two family brick · 0.62 FAR built · Flood zone AE
Locations of Work
Architecture
Floor 21p · 1 filing · 6 docs
Floor 1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW YORK DESIGN ARCHITECTS, LLP107/14/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AKS ARCHITECTURAL & ENGIN1957107/14/2026
Building Lifecycle
All (15)Filed (1)Special Inspection (14)
07/14/2026
Filed — Alteration
Filing for interior and exterior renovation due to a house fire. No change to use egress or occupancy. All as per plans only.
B01421548-I1
06/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Giuseppe Anzalone
06/24/2026
Special inspection requirement — Mechanical Systems
Giuseppe Anzalone
06/24/2026
Special inspection requirement — Final
Giuseppe Anzalone
06/24/2026
Special inspection requirement — Energy Code Compliance Inspections
Giuseppe Anzalone
06/24/2026
Special inspection requirement — Fire-Resistance Rated Construction
Giuseppe Anzalone
06/24/2026
Special inspection requirement — Insulation placement and R values
Giuseppe Anzalone
06/24/2026
Special inspection requirement — Fenestration air leakage
Giuseppe Anzalone
06/24/2026
Special inspection requirement — Interior lighting power
Giuseppe Anzalone
06/24/2026
Special inspection requirement — HVAC-R and service water heating system controls
Giuseppe Anzalone
06/24/2026
Special inspection requirement — Fenestration areas
Giuseppe Anzalone
06/24/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Giuseppe Anzalone
06/24/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Giuseppe Anzalone
06/24/2026
Special inspection requirement — Maintenance information
Giuseppe Anzalone
06/24/2026
Special inspection requirement — HVAC-R and service water heating equipment
Giuseppe Anzalone
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDVENTURE HOME SOLAR LLC01/04/2017
1 project · most recent 07/14/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/14/2026——Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PUZ-AK42NL 42,000 BTU · Heat Pump Outdoor ×1
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
06/24/2026Fire-Resistant Penetrations and JointsGiuseppe Anzalonespecial
06/24/2026Mechanical SystemsGiuseppe Anzalonespecial
06/24/2026FinalGiuseppe Anzaloneprogress
06/24/2026Energy Code Compliance InspectionsGiuseppe Anzaloneprogress
06/24/2026Fire-Resistance Rated ConstructionGiuseppe Anzaloneprogress
06/24/2026Insulation placement and R valuesGiuseppe Anzaloneenergy_progress
06/24/2026Fenestration air leakageGiuseppe Anzaloneenergy_progress
06/24/2026Interior lighting powerGiuseppe Anzaloneenergy_progress
06/24/2026HVAC-R and service water heating system controlsGiuseppe Anzaloneenergy_progress
06/24/2026Fenestration areasGiuseppe Anzaloneenergy_progress
06/24/2026HVAC-R and service water piping design and insulationGiuseppe Anzaloneenergy_progress
06/24/2026Fenestration and door U-factor and product ratingsGiuseppe Anzaloneenergy_progress
06/24/2026Maintenance informationGiuseppe Anzaloneenergy_progress
06/24/2026HVAC-R and service water heating equipmentGiuseppe Anzaloneenergy_progress
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026B01421548-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
01/03/2017340459818Open ↗
▸BISWORK PERMIT APPLICATION1
01/03/2017340459818Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISFLOOD ZONE DESIGN CERTIFICATION1
01/03/2017340459818Open ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B01421548-I1Open ↗
09/01/2026B01421548-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
01/03/2017340459818Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
01/03/2017340459818Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
01/03/2017340459818Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026B01421548-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026B01421548-I1Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
01/03/2017340459818Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
01/03/2017340459818Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026B01421548-I1Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
05/31/2017340459818Open ↗
01/03/2017340459818Open ↗
01/03/2017340459818Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
01/03/2017340459818Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/31/2017340459818Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
01/03/2017340459818Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
05/31/2017340459818Open ↗
▸Inspections & Test Reports5
▸BISTECHNICAL REPORT: RESPONSIBILITY4
05/31/2017340459818Open ↗
05/31/2017340459818Open ↗
01/03/2017340459818Open ↗
Showing 3 of 4 on file for this type
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)1
01/03/2017340459818Open ↗
▸Approvals, Objections & Sign-offs2
▸BISUtility Company PV System Interconnection Acknowledgement Letter1
05/31/2017340459818Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/31/2017340459818Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
05/31/2017340459818Open ↗
01/03/2017340459818Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
01/03/2017340459818Open ↗
▸Other Documents2
▸BISSUBSTANTIAL IMPROVEMENT CALCULATIONS1
01/03/2017340459818Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
01/03/2017340459818Open ↗