| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/28/2025 | Complete | GOODALL ELECTRIC CORP | General Wiring |
| Owner | Filings | Most Recent |
|---|---|---|
| HECAN CONSTRUCTION | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 06/22/2021 | $625K | — | Private party → Private party | $418/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| NIC 88 CORP | 8 | 08/18/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| BASIC GROUPS | 16 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| HECAN CONSTRUCTION CORP | General Contractor | 3 | 03/21/2026 |
| GOODALL ELECTRIC CORP | Electrical | 1 | 03/22/2026 |
| PIPESTYLISTS, INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| NIC 88 CORP | 8371 | 6 | 08/18/2025 |
| NIC DESIGN INC | 9758 | 2 | 08/19/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Signed-off | HECAN CONSTRUCTION CORP | 09/16/2024 |
| DOB NOW | Plumbing | Signed-off | T & T PLUMBING INC | 08/30/2024 |
| Date | Type | Result | Report |
|---|---|---|---|
| 09/16/2025 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 09/03/2025 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 07/23/2025 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 05/14/2025 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 05/13/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 12/04/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 12/04/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 12/04/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/18/2025 | HVAC-R and service water piping design and insulation | Eric Sun | energy_progress |
| 08/18/2025 | Fenestration areas | Eric Sun | energy_progress |
| 08/18/2025 | Interior lighting power | Eric Sun | energy_progress |
| 08/18/2025 | HVAC-R and service water heating equipment | Eric Sun | energy_progress |
| 08/18/2025 | Air barrier - visual inspection | Eric Sun | energy_progress |
| 08/18/2025 | HVAC-R and service water heating system controls | Eric Sun | energy_progress |
| 08/18/2025 | Fire-Resistant Penetrations and Joints | Eric Sun | special |
| 08/18/2025 | Tenant Protection Plan Compliance | Eric Sun | special |
| 08/18/2025 | Mechanical Systems | Eric Sun | special |
| 08/18/2025 | Energy Code Compliance Inspections | Eric Sun | progress |
| 08/18/2025 | Fire-Resistance Rated Construction | Eric Sun | progress |
| 08/18/2025 | Final | Eric Sun | progress |
| 08/18/2025 | Insulation placement and R values | Eric Sun | energy_progress |
| 08/18/2025 | Maintenance information | Eric Sun | energy_progress |
| 08/18/2025 | Fenestration and door U-factor and product ratings | Eric Sun | energy_progress |
| 07/31/2025 | Mechanical Systems | Eric Sun | special |
| 07/31/2025 | Fire-Resistant Penetrations and Joints | Eric Sun | special |
| 07/31/2025 | Tenant Protection Plan Compliance | Eric Sun | special |
| 07/31/2025 | Energy Code Compliance Inspections | Eric Sun | progress |
| 07/31/2025 | Final | Eric Sun | progress |
| 07/31/2025 | Fire-Resistance Rated Construction | Eric Sun | progress |
| 07/31/2025 | Air barrier - visual inspection | Eric Sun | energy_progress |
| 07/31/2025 | Fenestration areas | Eric Sun | energy_progress |
| 07/31/2025 | Interior lighting power | Eric Sun | energy_progress |
| 07/31/2025 | Maintenance information | Eric Sun | energy_progress |