| Owner | Filings | Most Recent |
|---|---|---|
| I G GROUP | 8 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| LAM & LAM ENGINEERING D.P.C. | 2 | 01/19/2026 |
| BILD ARCHITECTURE | 1 | 10/22/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| LAM & LAM DESIGNS DPC | 4 | 03/21/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| BIS | OT | ISSUED | I & G GROUP, INC | 03/02/2020 |
| BIS | PL | ISSUED | ZONE PLUMBING & HEATING C | 02/18/2020 |
| BIS | OT | ISSUED | I & G GROUP, INC | 02/04/2019 |
| BIS | OT | ISSUED | I & G GROUP, INC | 05/01/2018 |
| BIS | OT | ISSUED | I & G GROUP, INC | 05/05/2017 |
| BIS | OT | ISSUED | I & G GROUP, INC | 07/30/2015 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 01/19/2026 | — | — | Air Conditioning Systems | Cooling Cooper & Hunter ×40 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/19/2026 | — | — | 126 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/19/2026 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/17/2020 | Permit Issued | MARTINEZ ELECTRICAL CONT | General Wiring |
| 06/07/2018 | Permit Issued | R.A. PHILLIPS ELEC'L CONT | General Wiring |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/07/2026 | Interior lighting power | — | energy_progress |
| 07/07/2026 | Lighting in dwelling units | — | energy_progress |
| 07/07/2026 | Exterior lighting power | — | energy_progress |
| 07/07/2026 | Protection of exposed foundation insulation | — | energy_progress |
| 07/07/2026 | Permanent certificate | — | energy_progress |
| 07/07/2026 | Lighting controls | — | energy_progress |
| 01/19/2026 | Shutoff dampers | — | energy_progress |
| 12/19/2025 | Mechanical Systems | — | special |
| 12/19/2025 | Final | — | progress |
| 12/19/2025 | HVAC-R and service water heating equipment | — | energy_progress |
| 12/19/2025 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 12/19/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 12/19/2025 | Duct leakage testing, insulation and design | — | energy_progress |
| 12/19/2025 | HVAC-R and service water heating system controls | — | energy_progress |
| 12/19/2025 | Energy Code Compliance Inspections | — | progress |
| 12/19/2025 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 12/19/2025 | HVAC-R and service water heating equipment | — | energy_progress |
| 12/19/2025 | HVAC-R and service water heating system controls | — | energy_progress |
| 12/19/2025 | Maintenance information | — | energy_progress |
| 12/19/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 12/17/2025 | Sprinkler Systems | — | special |
| 11/07/2025 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 11/07/2025 | Fenestration areas | — | energy_progress |
| 11/07/2025 | Insulation placement and R values | — | energy_progress |
| 11/07/2025 | Fenestration air leakage | — | energy_progress |