← Back
General warehouse
250 JOHNSON AVENUE
BROOKLYN · BIN 3325868
💬 Discuss this project
1960Year Built
1Stories
E1Building Class
M1-1Zoning
15,290 sfGross Floor Area
1Units
2 Open Violations ▸FDNY Report ↗
General warehouse · Owner of record: SPG 250 JOHNSON AVE LLC · 15,290 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction20p · 2 filings · 20 docs
Floor 1Under Construction45p · 3 filings · 20 docs
MezzanineUnder Construction13p · 1 filing · 20 docs
2 jobs · most recent 01/27/2026
Ventilation Systems Air Conditioning Systems Heating Systems Others
FiledStatusContractorScopeMake / Model / Capacity
01/27/2026Permit IssuedCHIEF FIRE PREVENTION & MVentilation Systems—
07/31/2025Permit IssuedAMERICAN RESIDENTIAL CON*Air Conditioning Systems, Heating Systems, Others, Ventilation Systems
Cooling
Mitsubishi Electric PEFY-P72NMHSU-E 72,000 BTU · Vrf Indoor ×2
PEFY-P18NMAU-E4 18,000 BTU · Vrf Indoor ×1
PEFY-P27NMAU-F4 27,000 BTU · Fan Coil Indoor ×1
PEFY-P48NMAU-E4 48,000 BTU · Vrf Indoor ×1
PKFY-P24NKMU-E 24,000 BTU · Vrf Indoor ×1
PUHY-P120TNU 120,000 BTU · Vrf Outdoor ×1
PUHY-P144TNU-A 144,000 BTU · Vrf Outdoor ×1
Heating
Modine HD 125 125,000 BTU · Unit Heater ×1
Ventilation
Captiveaire 6030 ND-2 2,641 CFM · Kitchen Exhaust ×2
4824 VHB-G-NV 675 CFM · Kitchen Exhaust ×1
6024 ND-2 788 CFM · Kitchen Exhaust ×1
CAS-HVAC3-1.400-24-17.5T 3,000 CFM · Doas ×1
CAS-HVAC3-1.400-24-25T-DOAS 3,500 CFM · Doas ×1
DU33HFA 675 CFM · Exhaust Fan ×1
DU50HFA 788 CFM · Exhaust Fan ×1
USBI24DD-RM 4,034 CFM · Exhaust Fan ×1
Greenheck CSP-A390-VG 250 CFM · Exhaust Fan ×2
SP-A70 100 CFM · Exhaust Fan ×2
SCP-A710-VG 530 CFM · Exhaust Fan ×1
Other
Smoki Usa SMOKE ZAPPER SZ 200 350 CFM · Kitchen Exhaust ×1
1 job · most recent 07/31/2025
Sprinkler System
FiledStatusContractorScope
07/31/2025——Sprinkler System
1 job · most recent 07/31/2025
Gas Water/Sanitary
FiledStatusContractorScope
07/31/2025Permit IssuedORBIT PLBG & HTG INCGas, Water/Sanitary
1 job · most recent 04/16/2025
FiledStatusContractorScope
04/16/2025Permit IssuedFSM ELECTRICAL CORPORATIO1 meters, 1 new_meters
1 job · most recent 07/31/2025
Steel Concrete
FiledStatusContractorScope
07/31/2025Permit IssuedORBIT PLBG & HTG INCSteel, Concrete
Building Lifecycle
All (77)Filed (8)Permit Issued (6)Violation (8)Inspection (7)Objection (18)Special Inspection (30)
06/18/2026
Permit issued — Plumbing
B01186871-S6-PL
02/20/2026
Permit issued — Mechanical Systems
B01344589-I1-MS
02/19/2026
Permit issued — General Construction
B01186871-I1-GC
01/27/2026
Filed — Alteration
FILING FOR COMMERCIAL KITCHEN RANGEHOOD VENTILATION SYSTEM FOR REGALIS FOODS IN CONJUNCTION WITH ALT CO JOB#B01186871, AS SHOWN ON PLAN.
B01344589-I1
01/09/2026
Special inspection requirement — Final
De Gao
01/09/2026
Special inspection requirement — Mechanical Systems
De Gao
12/22/2025
Permit issued — Mechanical Systems
B01186871-S1-MS
10/17/2025
Objection resolved — Addressed
10/07/2025
Objection resolved — Addressed
08/27/2025
Objection resolved — Addressed
08/27/2025
Objection resolved — Addressed
08/27/2025
Objection resolved — Addressed
08/27/2025
Objection resolved — Addressed
08/27/2025
Objection resolved — Addressed
08/27/2025
Objection resolved — Addressed
08/27/2025
Special inspection requirement — Insulation placement and R values
Max Lee
08/27/2025
Special inspection requirement — Air barrier - visual inspection
Max Lee
08/27/2025
Special inspection requirement — Fenestration areas
Max Lee
08/27/2025
Special inspection requirement — Maintenance information
Max Lee
08/08/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/08/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/31/2025
Filed — Alteration CO
MODIFICATION OF EXISTING WET SPRINKLER SYSTEM ON 001 FLOOR AND MEZ. INSTALLATION OF NEW DRY HEAD SPRINKLERS FOR FREEZER ROOMS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
B01186871-S1
07/31/2025
Filed — Alteration CO
MODIFICATION OF EXISTING WET SPRINKLER SYSTEM ON 001 FLOOR AND MEZ. INSTALLATION OF NEW DRY HEAD SPRINKLERS FOR FREEZER ROOMS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
B01186871-S3
07/25/2025
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
07/25/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/23/2025
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
07/22/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/16/2025
Permit issued — Plumbing
B01186871-S6-PL
07/15/2025
Objection resolved — Addressed
07/10/2025
Objection raised — Fire_Protection
07/10/2025
Objection raised — Zoning
07/10/2025
Objection raised — Admin
07/10/2025
Objection raised — Cost
07/10/2025
Objection raised — Energy
07/10/2025
Objection raised — Admin
07/10/2025
Objection raised — Zoning
07/10/2025
Objection raised — Admin
07/10/2025
Objection raised — Plumbing
06/30/2025
Filed — Alteration CO
MODIFICATION OF EXISTING WET SPRINKLER SYSTEM ON 001 FLOOR AND MEZ. INSTALLATION OF NEW DRY HEAD SPRINKLERS FOR FREEZER ROOMS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
B01186871-S6
06/26/2025
Filed — Alteration CO
MODIFICATION OF EXISTING WET SPRINKLER SYSTEM ON 001 FLOOR AND MEZ. INSTALLATION OF NEW DRY HEAD SPRINKLERS FOR FREEZER ROOMS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
B01186871-I1
06/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
HENRY TORRES
06/26/2025
Special inspection requirement — Post-installed Anchors
HENRY TORRES
06/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
HENRY TORRES
06/26/2025
Special inspection requirement — Maintenance information
HENRY TORRES
06/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
HENRY TORRES
06/26/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Max Lee
03/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Max Lee
03/04/2025
Special inspection requirement — Sprinkler Systems
Max Lee
03/04/2025
Special inspection requirement — Post-installed Anchors
Max Lee
03/04/2025
Special inspection requirement — Shutoff dampers
Max Lee
03/04/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Max Lee
03/04/2025
Special inspection requirement — HVAC-R and service water heating system controls
Max Lee
03/04/2025
Special inspection requirement — Duct leakage testing, insulation and design
Max Lee
03/04/2025
Special inspection requirement — Maintenance information
Max Lee
03/04/2025
Special inspection requirement — HVAC-R and service water heating equipment
Max Lee
03/04/2025
Special inspection requirement — Final
Max Lee
03/04/2025
Special inspection requirement — Post-installed Anchors
Max Lee
03/04/2025
Special inspection requirement — Mechanical Systems
Max Lee
03/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Max Lee
02/26/2025
Special inspection requirement — Lighting controls
Max Lee
Latest 60 of 77 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SEAGIS PROPERTY GROUP1507/08/2026
250 JOHN603/21/2026
250 JOHNSON AVENUE203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/30/2021$6.5M—250 JOHNSON AVE LLC → SPG 250 JOHNSON AVE LLC$422/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RPO603/21/2026
CODE803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AMERICAN RESIDENTIAL CON*General Contractor207/08/2026
ORBIT PLBG & HTG INCPlumbing207/08/2026
CHIEF FIRE PREVENTION & MECHGeneral Contractor107/08/2026
ROYAL HVAC SYSTEMS INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
POLY ENGINEER, P.C.6110101/27/2026
PROJECT TACTICAL SOLUTION5859307/31/2025
HT ENGINEERING, PLLC6274106/30/2025
PROMISE CONSULTANTS1412210/29/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedORBIT PLBG & HTG INC06/18/2026
DOB NOWMechanical SystemsPermit IssuedCHIEF FIRE PREVENTION M02/20/2026
DOB NOWGeneral ConstructionPermit IssuedAMERICAN RESIDENTIAL CON*02/19/2026
DOB NOWMechanical SystemsPermit IssuedROYAL HVAC SYSTEMS INC12/22/2025
DOB NOWPlumbingPermit IssuedORBIT PLBG & HTG INC07/16/2025
DOB NOWGeneral ConstructionPermit IssuedAMERICAN RESIDENTIAL CON*01/24/2022
BISPLISSUEDMETROCITY GROUP,INC05/06/2013
BISPLISSUEDMETROCITY GROUP,INC03/13/2012
BISSPISSUEDACCURATE MECHANICAL INC03/12/2012
BISOTISSUEDUNITED RESTORATION SVCS O01/18/2012
BISOTISSUEDUNITED RESTORATION SVCS O10/12/2011
BISMHISSUEDUNITED RESTORATION SVCS O10/12/2011
BISPLISSUEDMETROCITY GROUP,INC11/19/2010
BISMHISSUEDUNITED RESTORATION SVCS O11/03/2010
BISPLISSUEDACCURATE MECHANICAL INC07/01/2010
BISOTISSUEDUNITED RESTORATION SVCS O05/24/2010
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
08/08/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/08/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/25/2025Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
07/25/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/23/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
07/22/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/07/2024Pass-Final SP - Up to 9 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
01/09/2026FinalDe Gaoprogress
01/09/2026Mechanical SystemsDe Gaospecial
08/27/2025Insulation placement and R valuesMax Leeenergy_progress
08/27/2025Air barrier - visual inspectionMax Leeenergy_progress
08/27/2025Fenestration areasMax Leeenergy_progress
08/27/2025Maintenance informationMax Leeenergy_progress
06/26/2025Fire-Resistant Penetrations and JointsHENRY TORRESspecial
06/26/2025Post-installed AnchorsHENRY TORRESspecial
06/26/2025HVAC-R and service water heating equipmentHENRY TORRESenergy_progress
06/26/2025Maintenance informationHENRY TORRESenergy_progress
06/26/2025HVAC-R and service water heating system controlsHENRY TORRESenergy_progress
06/26/2025Structural Stability – Alterations of existing buildingsMax Leespecial
03/11/2025Fire-Resistant Penetrations and JointsMax Leespecial
03/04/2025Sprinkler SystemsMax Leespecial
03/04/2025Post-installed AnchorsMax Leespecial
03/04/2025Shutoff dampersMax Leeenergy_progress
03/04/2025HVAC-R and service water piping design and insulationMax Leeenergy_progress
03/04/2025HVAC-R and service water heating system controlsMax Leeenergy_progress
03/04/2025Duct leakage testing, insulation and designMax Leeenergy_progress
03/04/2025Maintenance informationMax Leeenergy_progress
03/04/2025HVAC-R and service water heating equipmentMax Leeenergy_progress
03/04/2025FinalMax Leeprogress
03/04/2025Post-installed AnchorsMax Leespecial
03/04/2025Mechanical SystemsMax Leespecial
03/04/2025Fire-Resistant Penetrations and JointsMax Leespecial
Latest 25 of 44.
▾Documents — 152 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/31/2026B00646959-I1Request digital key ↗
08/23/2026B00656128-I1Request digital key ↗
08/23/2026B00656128-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits18
▸BISWORK PERMIT APPLICATION10
05/10/2013320159911Open ↗
03/14/2012320159911Open ↗
01/19/2012320396326Open ↗
Showing 3 of 10 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION8
09/28/2012320159911Open ↗
08/07/2012320159911Open ↗
05/17/2012320396326Open ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications48
▸DOB NOWProgress Inspector Seal & Signature16
09/23/2026B01186871-S1Open ↗
09/23/2026B01186871-S1Open ↗
09/23/2026B01344589-I1Open ↗
Showing 3 of 16 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
11/08/2012320159911Open ↗
08/07/2012320159911Open ↗
06/30/2012320172941Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/31/2026B00646959-I1Open ↗
08/23/2026B00656128-I1Open ↗
08/23/2026B00656128-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/23/2026B01186871-S1Open ↗
09/23/2026B01344589-I1Open ↗
09/01/2026B01186871-S3Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM5
08/07/2012320159911Open ↗
01/05/2012320396326Open ↗
01/05/2012320396326Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
08/07/2012320159911Open ↗
01/05/2012320396326Open ↗
06/16/2010320172941Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment27
▸BISSELF-CERT PLUMBING NOTICE16
06/27/2013320159911Open ↗
06/13/2013320159911Open ↗
06/13/2013320159911Open ↗
Showing 3 of 16 on file for this type
▸BISSCHEDULE B - PLUMBING4
09/28/2012320159911Open ↗
03/04/2011320172941Open ↗
06/16/2010320172941Open ↗
Showing 3 of 4 on file for this type
▸BISWATER METER PERMIT : DEP-METER2
06/15/2011320172941Open ↗
06/15/2011320172941Open ↗
▸BISRPZ/DDCV TEST REPORT : GEN215B2
06/15/2011320172941Open ↗
06/15/2011320172941Open ↗
▸BISSPRINKLER INSP REPORT : FP-851
06/15/2011320172941Open ↗
▸BISSEWER CONNECTION: DEP SD1 & SD21
03/14/2011320172941Open ↗
▸BISSEWER/HOUSE CON SIGNOFF: DEP HC 0211
05/09/2011320172941Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist2
08/31/2026B00646959-I1Open ↗
08/13/2026B01186871-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00646959-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00646959-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00646959-I1Open ↗
▸Environmental & Asbestos13
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/31/2026B00646959-I1Open ↗
08/23/2026B00656128-P1Open ↗
08/23/2026B00656128-I1Open ↗
Showing 3 of 9 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'4
01/05/2012320396326Open ↗
06/16/2010320172941Open ↗
04/30/2010320159911Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
05/25/2012320396326Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/25/2012320396326Open ↗
▸BISTECHNICAL REPORT: ENERGY1
01/05/2012320396326Open ↗
▸Inspections & Test Reports1
▸BISHYDRO FLOW TEST LETTER1
06/16/2010320172941Open ↗
▸Approvals, Objections & Sign-offs11
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
06/14/2013320159911Open ↗
01/16/2013320159911Open ↗
11/08/2012320159911Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
01/05/2012320396326Open ↗
06/15/2010320172941Open ↗
04/30/2010320159911Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
08/07/2012320159911Open ↗
▸BISTAP LETTER - DOM SVC : DEP-DOM1
06/15/2011320172941Open ↗
▸BISCCD1-Construction Code Determination1
08/28/2012320159911Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT7
11/08/2012320159911Open ↗
08/07/2012320159911Open ↗
06/30/2012320172941Open ↗
Showing 3 of 7 on file for this type
▸Filing & Intake Forms8
▸BISADDITIONAL INFORMATION5
10/03/2012320159911Open ↗
08/09/2012320159911Open ↗
05/17/2012320396326Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING COVER SHEET3
01/05/2012320396326Open ↗
06/16/2010320172941Open ↗
04/30/2010320159911Open ↗
▸Other Documents2
▸DOB NOWProperty Ownership Certification2
08/31/2026B00646959-I1Open ↗
08/21/2026B01186871-I1Open ↗