← Back
Two family brick
88 REMSEN STREET
BROOKLYN · BIN 3326040
💬 Discuss this project
1838Year Built
4Stories
B1Building Class
R6Zoning
8,282 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family brick · Owner of record: 88 REMSEN LLC · 3,750 sf lot · 2.21 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
CellarUnder Construction13p · 1 filing · 20 docs
Sub-BasementUnder Construction16p · 1 filing · 20 docs
1 job · most recent 11/11/2025
Air Conditioning Systems Heating and Air Conditioning Systems Others Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/11/2025Permit IssuedNEW WAVE DESIGN & CONTRACAir Conditioning Systems, Heating and Air Conditioning Systems, Others, Ventilation Systems
Cooling
Mitsubishi Electric PVFY-P24NAMU-E1 24,000 BTU · Vrf Indoor ×2
MXZ-SM48NAM2-U1 48,000 BTU · Heat Pump Outdoor ×1
MXZ-SM48NAMHZ2 48,000 BTU · Heat Pump Outdoor ×1
PVFY-P18NAMU-E1 18,000 BTU · Vrf Indoor ×1
PVFY-P30NAMU-E1 30,000 BTU · Vrf Indoor ×1
Heat / Cool
Mitsubishi Electric PVFY-P24NAMU-EQ 24,032 BTU · Vrf Indoor ×4
Mitsubishi Electric Trans HVAC US: city Multi VRF Outdoor Unit Schedule MXZ-SM48NAM2-U1 MXZ-SM48NAMHZ2-U1 48,000 BTU ×2
Other
1 job · most recent 11/11/2025
Gas Water/Sanitary
FiledStatusContractorScope
11/11/2025Permit IssuedARISTA PLBG & HTG CORPGas, Water/Sanitary
2 jobs · most recent 09/23/2026
General Wiring
FiledStatusContractorScope
09/23/2026CompleteDAVEN ELECTRIC CORP—
02/12/2026Permit IssuedGANLY ELECTRICAL CORPGeneral Wiring
1 job · most recent 11/11/2025
Steel
FiledStatusContractorScope
11/11/2025Permit IssuedNEW WAVE DESIGN & CONTRACSteel
Building Lifecycle
All (28)Filed (4)Permit Issued (4)Violation (2)Inspection (5)Objection (5)Special Inspection (8)
04/15/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/31/2026
Permit issued — General Construction
B01098534-I1-GC
12/02/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Young Suh
11/11/2025
Filed — Alteration
FILING HEREWITH PLUMBING WORK IN CONJUNCTION WITH APARTMENT RENOVATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01098534-P1
09/30/2025
Permit issued — General Construction
B01098534-I1-GC
08/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Young Suh
07/21/2025
Objection resolved — Resolved
04/09/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/29/2025
Objection resolved — Addressed
01/09/2025
Objection raised — Fire_Protection
01/09/2025
Objection raised — Scope
01/06/2025
Permit issued — Plumbing
B01098534-S3-PL
12/23/2024
Objection raised — Scope
12/17/2024
Filed — Alteration
FILING HEREWITH PLUMBING WORK IN CONJUNCTION WITH APARTMENT RENOVATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01098534-S2
12/17/2024
Filed — Alteration
FILING HEREWITH PLUMBING WORK IN CONJUNCTION WITH APARTMENT RENOVATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01098534-S3
12/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
12/04/2024
Special inspection requirement — Mechanical Systems
12/04/2024
Special inspection requirement — Final
08/30/2024
Permit issued — General Construction
B01098534-I1-GC
08/26/2024
Filed — Alteration
FILING HEREWITH PLUMBING WORK IN CONJUNCTION WITH APARTMENT RENOVATIONS AS PER PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01098534-I1
08/19/2024
Special inspection requirement — Final
Elizabeth Roberts
08/19/2024
Special inspection requirement — Fire-Resistance Rated Construction
Young Suh
08/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Young Suh
04/24/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/15/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
12/13/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
04/28/2011
Violation issued (ECB, closed)
Unknown
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
88 REMSEN1407/08/2026
VBOX VENTURES903/22/2026
NYC DEPT OF DESIGN COSTRUCTI403/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/25/2022$18.3M—VBOX VENTURES, LLC → 88 REMSEN LLC$2,210/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
D'ANTONIO CONSULTING ENGINEERS311/11/2025
ELIZABETH ROBERTS ARCHITECTURE & DE108/26/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW WAVE DESIGN & CONTRACTINGGeneral Contractor307/08/2026
ARISTA PLBG & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALAN MARGOLIN & ASSOC423311/11/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedNEW WAVE DESIGN & CONTRAC03/31/2026
DOB NOWGeneral ConstructionPermit IssuedNEW WAVE DESIGN & CONTRAC09/30/2025
DOB NOWPlumbingPermit IssuedARISTA PLBG & HTG CORP01/06/2025
DOB NOWGeneral ConstructionPermit IssuedNEW WAVE DESIGN & CONTRAC08/30/2024
BISPLISSUEDMARATHON MECHANICAL LLC04/22/2014
BISOTISSUEDSLAVA SH INC04/14/2014
BISPLISSUEDFLINT MECHANICAL CORP02/22/2012
BIS—ISSUEDVBOX VENTURES LLC11/16/2009
BISBLISSUEDFLINT MECHANICAL CORP09/14/2009
BISMHISSUEDFOUR STAR AIR CON'D CO LL06/24/2009
BISOTISSUEDZORNICK CONTRACTING CORP11/13/2008
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/15/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/02/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/09/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/15/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
12/13/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
11/21/2025Fire-Resistant Penetrations and JointsYoung Suhspecial
08/20/2025Fire-Resistant Penetrations and JointsYoung Suhspecial
12/04/2024Fire-Resistant Penetrations and Joints—special
12/04/2024Mechanical Systems—special
12/04/2024Final—progress
08/19/2024FinalElizabeth Robertsprogress
08/19/2024Fire-Resistance Rated ConstructionYoung Suhprogress
08/19/2024Fire-Resistant Penetrations and JointsYoung Suhspecial
▾Documents — 153 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/19/2026B01098534-P1Request digital key ↗
08/19/2026B01098534-S3Request digital key ↗
08/19/2026B01098534-S1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits31
▸BISPLAN / WORK APPROVAL APPLICATION19
07/29/2022320958415Open ↗
07/28/2014320958415Open ↗
06/23/2014320958415Open ↗
Showing 3 of 19 on file for this type
▸BISWORK PERMIT APPLICATION9
06/23/2014320958415Open ↗
06/18/2014320958415Open ↗
02/28/2012310206531Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWLPC Approval/Permit2
08/13/2026B01098534-S2Open ↗
08/13/2026B01098534-I1Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
11/15/2010310215503Open ↗
▸Seals & Professional Certifications26
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
11/14/2014320958415Open ↗
06/23/2014320958415Open ↗
08/03/2012320047016Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
06/23/2014320958415Open ↗
11/18/2010310298317Open ↗
11/17/2010310298317Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/19/2026B01098534-P1Open ↗
08/19/2026B01098534-S3Open ↗
08/19/2026B01098534-S2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/29/2026B01098534-S3Open ↗
08/27/2026B01098534-I1Open ↗
08/27/2026B01098534-P1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
07/07/2009320047016Open ↗
02/20/2009310298317Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026B01098534-I1Open ↗
08/27/2026B01098534-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/23/2014320958415Open ↗
▸Trade Schedules & Equipment26
▸BISSCHEDULE B - PLUMBING6
07/28/2014320958415Open ↗
05/11/2012310206531Open ↗
02/22/2011310206531Open ↗
Showing 3 of 6 on file for this type
▸BISSELF-CERT PLUMBING NOTICE6
11/06/2014320958415Open ↗
10/22/2014320958415Open ↗
06/21/2012310206531Open ↗
Showing 3 of 6 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT6
07/29/2011310298317Open ↗
07/29/2011310298317Open ↗
07/29/2011310298317Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT5
09/14/2011320047016Open ↗
04/01/2011320047016Open ↗
01/12/2010320047016Open ↗
Showing 3 of 5 on file for this type
▸BISEQUIPMENT USE PERMITS2
07/29/2011310298317Open ↗
07/29/2011310298317Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
06/23/2014320958415Open ↗
▸Safety & Tenant Protection5
▸BISSTREET TREE CHECKLIST4
06/23/2014320958415Open ↗
07/07/2009320047016Open ↗
02/20/2009310298317Open ↗
Showing 3 of 4 on file for this type
▸BISST-1 Street Tree Checklist1
10/15/2009310215503Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/19/2026B01098534-P1Open ↗
08/19/2026B01098534-S3Open ↗
08/19/2026B01098534-S1Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
02/20/2009310298317Open ↗
10/07/2008310206531Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
07/07/2009320047016Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/23/2014320958415Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
06/23/2014320958415Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
07/06/2022320958415Open ↗
▸Inspections & Test Reports2
▸BISNOTIF.-PROPOSED STEAM/HOT WATER INSPECTION2
04/01/2011320047016Open ↗
10/22/2009320047016Open ↗
▸Approvals, Objections & Sign-offs23
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST8
10/24/2022320958415Open ↗
08/03/2012320047016Open ↗
07/27/2012310206531Open ↗
Showing 3 of 8 on file for this type
▸BISADMINISTRATIVE OBJECTIONS5
06/23/2014320958415Open ↗
07/07/2009320047016Open ↗
02/20/2009310298317Open ↗
Showing 3 of 5 on file for this type
▸BISLANDMARKS APPROVAL4
08/03/2012320047016Open ↗
07/27/2012310206531Open ↗
10/15/2009310215503Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
06/23/2014320958415Open ↗
08/03/2012320047016Open ↗
08/29/2011310298317Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE2
06/14/2011310215503Open ↗
10/09/2009310215503Open ↗
▸BISLANDMARKS SIGNOFF1
10/24/2022320958415Open ↗
▸Cost, Insurance & Ownership12
▸BISCOST AFFIDAVIT12
11/14/2014320958415Open ↗
06/23/2014320958415Open ↗
08/03/2012320047016Open ↗
Showing 3 of 12 on file for this type
▸Filing & Intake Forms10
▸BISADDITIONAL INFORMATION8
09/26/2011310215503Open ↗
06/14/2011310215503Open ↗
06/03/2011310298317Open ↗
Showing 3 of 8 on file for this type
▸BISEFILING COVER SHEET2
06/23/2014320958415Open ↗
02/20/2009310298317Open ↗
▸Other Documents2
▸BISSEPTIC - SUPPORTING DOCUMENTATION1
12/11/2014320958415Open ↗
▸DOB NOWProof of Historic Building1
08/13/2026B01098534-I1Open ↗