← Back
Factory, light manufacturing
799 SNEDIKER AVENUE
BROOKLYN · BIN 3327059
💬 Discuss this project
1930Year Built
1Stories
F5Building Class
M1-1Zoning
27,440 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Factory, light manufacturing · Owner of record: 800 HINSDALE STREET LLC · 30,000 sf lot · 0.91 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbingCivil
Roof3p · 3 filings · 20 docs
Floor 16p · 2 filings · 14 docs
1 job · most recent 03/09/2024
General Wiring
FiledStatusContractorScope
03/09/2024CompleteDENALI ELECTRIC CORPGeneral Wiring
Building Lifecycle
All (69)Filed (9)Permit Issued (8)Signed Off (4)Violation (3)Inspection (6)Objection (28)Special Inspection (11)
01/31/2025
Violation issued (FDNY_NOV, closed)
04/30/2024
Signed off — Alteration
Mechanical work filed in conjunction with interior renovation of warehouse. No change in use, egress and occupancy.
B00680960-I1
04/10/2024
Signed off — Alteration
Plumbing/Sprinkler work filed in conjunction with interior renovation of warehouse. No change in use, egress and occupancy.
B00680953-I1
03/18/2024
Permit issued — Plumbing
B00680953-I1-PL
02/16/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/14/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/08/2024
Permit issued — Plumbing
B00680953-I1-EW-SP
02/05/2024
Special inspection requirement — Sprinkler Systems
MAURICIO ANDRADE
02/01/2024
Filed — Alteration
Plumbing/Sprinkler work filed in conjunction with interior renovation of warehouse. No change in use, egress and occupancy.
B00680953-P4
02/01/2024
Special inspection requirement — Sprinkler Systems
MAURICIO ANDRADE
01/18/2024
Objection resolved — Addressed
01/17/2024
Objection raised — Scope
01/09/2024
Filed — Alteration
Plumbing/Sprinkler work filed in conjunction with interior renovation of warehouse. No change in use, egress and occupancy.
B00680953-P3
01/09/2024
Special inspection requirement — Sprinkler Systems
MAURICIO ANDRADE
01/04/2024
Signed off — Alteration
Slab replacement. No change in use, egress and occupancy.
B00693731-I1
01/04/2024
Objection raised — Scope
01/04/2024
Objection resolved — Addressed
01/03/2024
Objection resolved — Addressed
01/03/2024
Objection resolved — Addressed
12/27/2023
Objection raised — Scope
12/27/2023
Objection raised — Scope
12/21/2023
Filed — Alteration
Plumbing/Sprinkler work filed in conjunction with interior renovation of warehouse. No change in use, egress and occupancy.
B00680953-P2
12/20/2023
Special inspection requirement — Sprinkler Systems
MAURICIO ANDRADE
12/15/2023
Signed off — Alteration
B00672251-I1
12/13/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/05/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/05/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/28/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/22/2023
Permit issued — Plumbing
B00680953-I1-PL
03/14/2023
Filed — Alteration
Plumbing/Sprinkler work filed in conjunction with interior renovation of warehouse. No change in use, egress and occupancy.
B00680953-P1
02/08/2023
Filed — Alteration
B00672251-P1
02/08/2023
Special inspection requirement — Fire-Resistance Rated Construction
MAURICIO ANDRADE
02/08/2023
Special inspection requirement — Energy Code Compliance Inspections
MAURICIO ANDRADE
02/08/2023
Special inspection requirement — Final
MAURICIO ANDRADE
02/08/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
MAURICIO ANDRADE
02/08/2023
Special inspection requirement — Interior lighting power
MAURICIO ANDRADE
02/08/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
01/13/2023
Permit issued — Sprinklers
B00680953-I1-PL
01/06/2023
Permit issued — Structural
B00693731-I1-ST
12/27/2022
Permit issued — Sprinklers
B00680953-I1-EW-SP
11/03/2022
Permit issued — General Construction
B00672251-I1-GC
11/03/2022
Permit issued — Mechanical Systems
B00680960-I1-MS
05/26/2022
Special inspection requirement — Sprinkler Systems
MAURICIO ANDRADE
05/17/2022
Violation issued (FDNY_NOV, closed)
04/22/2022
Objection resolved — Addressed
04/11/2022
Filed — Alteration
Slab replacement. No change in use, egress and occupancy.
B00693731-I1
03/31/2022
Objection resolved — Addressed
03/29/2022
Objection resolved — Addressed
03/29/2022
Objection resolved — Addressed
03/29/2022
Objection resolved — Addressed
03/25/2022
Objection resolved — Addressed
03/25/2022
Objection resolved — Addressed
03/25/2022
Objection resolved — Addressed
03/25/2022
Objection resolved — Addressed
03/14/2022
Objection raised — Scope
03/14/2022
Objection resolved — Addressed
03/10/2022
Filed — Alteration
Mechanical work filed in conjunction with interior renovation of warehouse. No change in use, egress and occupancy.
B00680960-I1
03/10/2022
Objection raised — Structural
03/10/2022
Objection raised — Structural
03/10/2022
Objection raised — Structural
Latest 60 of 69 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
800 HINSDALE STREET1003/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/02/2021$6.9M—JET HARDWARE MANUFACTURING CORP. → 800 HINSDALE STREET LLC$251/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MEYERS+ ENGINEERS602/01/2024
KOOKOO DESIGN LLC202/08/2023
STRUCTURAL ENGINEERING TECHNOLOGIES104/11/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NICOLOSI BROS INCGeneral Contractor407/08/2026
PAL-MAR PLBG & HTG INCPlumbing307/08/2026
ABDUL AZIZElectrical103/21/2026
AZIZ ABDULElectrical103/21/2026
ALL PRO PLBG & HTG INCFire Protection107/08/2026
FIVE BOROUGH NYC LLCFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PSI AGENCY INC.254902/01/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPAL-MAR PLBG & HTG INC03/18/2024
DOB NOWPlumbingSigned-offFIVE BOROUGH NYC LLC02/08/2024
DOB NOWPlumbingSigned-offPAL-MAR PLBG & HTG INC03/22/2023
DOB NOWSprinklersSigned-offPAL-MAR PLBG & HTG INC01/13/2023
DOB NOWStructuralSigned-offNICOLOSI BROS INC01/06/2023
DOB NOWSprinklersSigned-offALL PRO PLBG & HTG INC12/27/2022
DOB NOWGeneral ConstructionSigned-offNICOLOSI BROS INC11/03/2022
DOB NOWMechanical SystemsSigned-offNICOLOSI BROS INC11/03/2022
BISMHISSUEDAIRCRAFT AIR COND CORP03/25/2004
BISMHISSUEDJET HARDWARE MANUFACTURING04/10/1998
BISMHISSUEDJET HARDWARE04/07/1998
BISPLISSUEDMKA PIPING & HTG CORP03/25/1998
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
02/16/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/14/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/13/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/05/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/05/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/28/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
02/05/2024Sprinkler SystemsMAURICIO ANDRADEspecial
02/01/2024Sprinkler SystemsMAURICIO ANDRADEspecial
01/09/2024Sprinkler SystemsMAURICIO ANDRADEspecial
12/20/2023Sprinkler SystemsMAURICIO ANDRADEspecial
02/08/2023Fire-Resistance Rated ConstructionMAURICIO ANDRADEprogress
02/08/2023Energy Code Compliance InspectionsMAURICIO ANDRADEprogress
02/08/2023FinalMAURICIO ANDRADEprogress
02/08/2023Structural Stability – Alterations of existing buildingsMAURICIO ANDRADEspecial
02/08/2023Interior lighting powerMAURICIO ANDRADEenergy_progress
02/08/2023Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
05/26/2022Sprinkler SystemsMAURICIO ANDRADEspecial
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/31/2026B00672251-P1Request digital key ↗
08/31/2026B00672251-I1Request digital key ↗
08/31/2026B00680953-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Seals & Professional Certifications17
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/31/2026B00672251-P1Open ↗
08/31/2026B00672251-I1Open ↗
08/31/2026B00680953-P4Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/19/2026B00680953-P3Open ↗
09/02/2026B00672251-P1Open ↗
08/26/2026B00680953-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
09/02/2026B00672251-P1Open ↗
09/02/2026B00672251-P1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/31/2026B00672251-I1Open ↗
08/31/2026B00672251-P1Open ↗
08/31/2026B00680953-P4Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/15/2026B00680960-I1Open ↗
08/13/2026B00672251-I1Open ↗