← Back
Shopping center, with or without parking
933 WORTMAN AVENUE
BROOKLYN · BIN 3327452
💬 Discuss this project
1965Year Built
1Stories
K6Building Class
R5Zoning
34,788 sfGross Floor Area
30Units
1 Open Violation ▸FDNY Report ↗
Shopping center, with or without parking · Owner of record: 921 PENN AVE LLC · 66,343 sf lot · 0.52 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanicalPlumbing
Roof1p · 1 filing · 5 docs
Floor 112p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MBM ASSOCIATES1307/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NASIR J, KHANZADA LLC512/13/2022
DAVI ARCHITECTURE, PC501/24/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LINE DESIGN103/21/2026
NASIR J. KHANZADA LLC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MULTICRAFT HOME REMODELGeneral Contractor407/08/2026
HI-TECH CONTRACTORS CORPGeneral Contractor303/21/2026
JOSEPH WEINSTEIN ELECTRICElectrical103/22/2026
DYNAMIC PLBG & SPRKLR CORPlumbing107/08/2026
E. MULE & SON PLBG & HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NASIR J. KHANZADA LLC1527512/13/2022
DAVI ARCHITECTURE, PC5168501/24/2022
Building Lifecycle
All (91)Filed (10)Permit Issued (5)Signed Off (3)Violation (14)Inspection (13)Objection (22)Special Inspection (24)
08/12/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/12/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/11/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/22/2024
Violation issued (FDNY_ORDER, closed)
10/22/2024
Violation issued (FDNY_ORDER, closed)
10/22/2024
Violation issued (FDNY_ORDER, closed)
10/22/2024
Violation issued (FDNY_ORDER, closed)
10/22/2024
Violation issued (FDNY_ORDER, closed)
10/22/2024
Violation issued (FDNY_ORDER, closed)
10/22/2024
Violation issued (FDNY_ORDER, closed)
10/22/2024
Violation issued (FDNY_ORDER, closed)
02/21/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/05/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/04/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/27/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
12/20/2022
Special inspection requirement — Energy Code Compliance Inspections
Nasir Khanzada
12/20/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
12/13/2022
Filed — Alteration
PLUMBING FILING IN CONJUNCTION WITH ALT-2 FILING FOR RENOVATION OF EXISTING STORE TO CHARLEY'S RESTAURANT
B00747927-P2
12/13/2022
Special inspection requirement — Energy Code Compliance Inspections
Nasir Khanzada
12/13/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
11/22/2022
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
11/04/2022
Objection resolved — Addressed
11/04/2022
Objection resolved — Addressed
11/04/2022
Objection resolved — Addressed
11/03/2022
Objection raised — Energy
11/03/2022
Objection raised — Other
11/03/2022
Objection raised — Inspections
10/31/2022
Filed — Alteration
PLUMBING FILING IN CONJUNCTION WITH ALT-2 FILING FOR RENOVATION OF EXISTING STORE TO CHARLEY'S RESTAURANT
B00747927-P1
10/31/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
10/31/2022
Special inspection requirement — Energy Code Compliance Inspections
Nasir Khanzada
10/19/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/19/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/03/2022
Permit issued — Plumbing
B00747927-I1-PL
09/09/2022
Permit issued — General Construction
B00742930-I1-GC
08/04/2022
Objection resolved — Addressed
08/04/2022
Objection resolved — Addressed
07/19/2022
Filed — Alteration
MECHANICAL FILING IN CONJUCTION WITH ALT-2 JOB OF RENOVATION OF EXISTING STORE TO CHARLEY'S RESTAURANT.
B00747972-I1
07/19/2022
Special inspection requirement — Maintenance information
Nasir Khanzada
07/19/2022
Special inspection requirement — HVAC-R and service water heating equipment
Nasir Khanzada
07/19/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
07/19/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Nasir Khanzada
07/19/2022
Special inspection requirement — HVAC-R and service water heating system controls
Nasir Khanzada
07/15/2022
Objection resolved — Addressed
07/15/2022
Objection resolved — Addressed
07/07/2022
Objection resolved — Addressed
07/07/2022
Objection resolved — Addressed
07/07/2022
Objection resolved — Addressed
07/07/2022
Objection resolved — Addressed
07/06/2022
Objection raised — Fire_Protection
07/06/2022
Objection raised — Accessibility
07/06/2022
Objection raised — Structural
07/06/2022
Objection raised — Accessibility
07/06/2022
Objection raised — Fire_Protection
07/06/2022
Objection raised — Scope
07/06/2022
Objection raised — Scope
06/09/2022
Objection raised — Scope
06/02/2022
Filed — Alteration
PLUMBING FILING IN CONJUNCTION WITH ALT-2 FILING FOR RENOVATION OF EXISTING STORE TO CHARLEY'S RESTAURANT
B00747927-I1
05/31/2022
Filed — Alteration
APPLICATION FILED TO INTERIOR RENOVATION OF EXISTINGSTORE TO CHARLEY'S RESTURANT
B00742930-I1
05/31/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nasir Khanzada
05/31/2022
Special inspection requirement — Lighting controls
Nasir Khanzada
Latest 60 of 91 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedCITYWIDE PLBG HTG & SPKLS10/03/2022
DOB NOWGeneral ConstructionPermit IssuedHI-TECH CONTRACTORS CORP09/09/2022
DOB NOWPlumbingSigned-offE. MULE & SON PLBG & HTG01/24/2022
DOB NOWGeneral ConstructionSigned-offMULTICRAFT HOME REMODEL12/23/2021
DOB NOWStructuralSigned-offMULTICRAFT HOME REMODEL09/16/2021
1 project · most recent 07/19/2022
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
07/19/2022——Air Conditioning Systems, Heating Systems
Cooling
Rheem RKNLA060CK13E 60,000 BTU · Rooftop Unit ×2
Heating
Rheem RKNLA060CK13B 135,000 BTU · Condensing Unit ×2
1 project · most recent 12/13/2022
Gas Water/Sanitary
FiledStatusContractorScope
12/13/2022Permit IssuedDYNAMIC PLBG & SPRKLR CORGas, Water/Sanitary
3 projects · most recent 03/12/2023
General Wiring
FiledStatusContractorScope
03/12/2023Permit IssuedNAS ELECTRIC CORPGeneral Wiring
09/23/2022CompleteJOSEPH WEINSTEIN ELECTRICGeneral Wiring
01/29/2022Permit IssuedV. VASS ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
08/12/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/12/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/11/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/21/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/05/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/04/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/27/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/22/2022Pass-Final PL - UndergroundPassView ↗
10/19/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/19/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/05/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/05/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/10/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
12/20/2022Energy Code Compliance InspectionsNasir Khanzadaprogress
12/20/2022Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
12/13/2022Energy Code Compliance InspectionsNasir Khanzadaprogress
12/13/2022Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
10/31/2022Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
10/31/2022Energy Code Compliance InspectionsNasir Khanzadaprogress
07/19/2022Maintenance informationNasir Khanzadaenergy_progress
07/19/2022HVAC-R and service water heating equipmentNasir Khanzadaenergy_progress
07/19/2022Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
07/19/2022HVAC-R and service water piping design and insulationNasir Khanzadaenergy_progress
07/19/2022HVAC-R and service water heating system controlsNasir Khanzadaenergy_progress
05/31/2022Structural Stability – Alterations of existing buildingsNasir Khanzadaspecial
05/31/2022Lighting controlsNasir Khanzadaenergy_progress
05/31/2022Interior lighting powerNasir Khanzadaenergy_progress
05/31/2022Mechanical SystemsNasir Khanzadaspecial
05/31/2022FinalNasir Khanzadaprogress
05/20/2022Energy Code Compliance InspectionsNasir Khanzadaprogress
05/20/2022Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
05/20/2022Fire-Resistance Rated ConstructionNasir Khanzadaprogress
01/31/2022Lighting controlsBenedetto Davienergy_progress
01/31/2022Interior lighting powerBenedetto Davienergy_progress
01/31/2022Fire-Resistant Penetrations and JointsBenedetto Davispecial
01/31/2022FinalBenedetto Daviprogress
01/21/2022Fire-Resistant Penetrations and JointsBenedetto Davispecial
▾Documents — 53 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
09/01/2026B00485433-I1Request digital key ↗
09/01/2026B00485433-I1Request digital key ↗
09/01/2026B00485426-P1Request digital key ↗
Showing 3 of 11 on file for this type
▸Seals & Professional Certifications29
▸DOB NOWProgress Inspector Seal & Signature11
08/29/2026B00747927-P1Open ↗
08/27/2026B00742930-I1Open ↗
08/27/2026B00742930-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
09/01/2026B00485433-I1Open ↗
09/01/2026B00485426-P1Open ↗
09/01/2026B00485426-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/31/2026B00485433-P1Open ↗
08/29/2026B00747927-P1Open ↗
08/27/2026B00742930-I1Open ↗
Showing 3 of 8 on file for this type
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
09/01/2026B00485433-I1Open ↗
09/01/2026B00485433-I1Open ↗
09/01/2026B00485433-P1Open ↗
Showing 3 of 12 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00485426-I1Open ↗