← Back
Factory, industrial, miscellaneous
4004 NEW UTRECHT AVENUE
BROOKLYN · BIN 3328579
💬 Discuss this project
1930Year Built
2Stories
F9Building Class
R6Zoning
4,815 sfGross Floor Area
3Units
8 Open Violations ▸FDNY Report ↗
Factory, industrial, miscellaneous · Owner of record: THE JOSEPH DICAMILLO JR. 2008 TRUST · 2,945 sf lot · 1.63 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 20 docs
Floor 1Under Construction3p · 1 filing · 20 docs
CellarUnder Construction4p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DICAMILLO PARTNERSHIP1304/09/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KEMS ENGINEERING AND CONSTRUCTION402/04/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEWSAN CONSULTANTS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CONTROL PLBG & HTG INCPlumbing207/08/2026
PARKWAY MECHANICAL CORPGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EC SPECIAL INSPECTIONS8355402/04/2026
Building Lifecycle
All (43)Filed (4)Permit Issued (3)Violation (10)Inspection (8)Special Inspection (18)
08/18/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/07/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/01/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/09/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/04/2026
Permit issued — Boiler Equipment
B01305463-S2-BE
03/02/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
02/04/2026
Filed — Alteration
FILE TO REGISTER A GAS FIRED WATER HEATER AND INSTALL GAS PIPING FOR TWO (2) NEW FURNACES ON 1st FLOOR AND REGISTER TWO (2) BOILERS IN CELLAR.
B01305463-S2
02/02/2026
Filed — Alteration
FILE TO REGISTER A GAS FIRED WATER HEATER AND INSTALL GAS PIPING FOR TWO (2) NEW FURNACES ON 1st FLOOR AND REGISTER TWO (2) BOILERS IN CELLAR.
B01305463-P1
02/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ABDALLAH ELCHERBINI
02/02/2026
Special inspection requirement — Tenant Protection Plan Compliance
02/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ABDALLAH ELCHERBINI
02/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Steven Bendoraitis
02/02/2026
Special inspection requirement — Maintenance information
Steven Bendoraitis
02/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
Steven Bendoraitis
02/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
Steven Bendoraitis
02/02/2026
Special inspection requirement — Heating Systems
ABDALLAH ELCHERBINI
01/22/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
01/22/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/14/2026
Special inspection requirement — Tenant Protection Plan Compliance
ABDALLAH ELCHERBINI
01/13/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
01/07/2026
Permit issued — Plumbing
B01305463-S1-PL
12/02/2025
Permit issued — Mechanical Systems
B01305463-I1-MS
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/04/2025
Filed — Alteration
FILE TO REGISTER A GAS FIRED WATER HEATER AND INSTALL GAS PIPING FOR TWO (2) NEW FURNACES ON 1st FLOOR AND REGISTER TWO (2) BOILERS IN CELLAR.
B01305463-I1
11/04/2025
Filed — Alteration
FILE TO REGISTER A GAS FIRED WATER HEATER AND INSTALL GAS PIPING FOR TWO (2) NEW FURNACES ON 1st FLOOR AND REGISTER TWO (2) BOILERS IN CELLAR.
B01305463-S1
11/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ABDALLAH ELCHERBINI
11/03/2025
Special inspection requirement — HVAC-R and service water heating system controls
Steven Bendoraitis
11/03/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Steven Bendoraitis
11/03/2025
Special inspection requirement — Maintenance information
Steven Bendoraitis
11/03/2025
Special inspection requirement — HVAC-R and service water heating equipment
Steven Bendoraitis
11/03/2025
Special inspection requirement — Energy Code Compliance Inspections
Steven Bendoraitis
10/20/2025
Special inspection requirement — Mechanical Systems
ABDALLAH ELCHERBINI
10/20/2025
Special inspection requirement — Tenant Protection Plan Compliance
ABDALLAH ELCHERBINI
10/20/2025
Special inspection requirement — Final
Steven Bendoraitis
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/04/1998
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/16/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/16/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/29/1995
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentPermit IssuedCONTROL PLBG & HTG INC03/04/2026
DOB NOWPlumbingPermit IssuedCONTROL PLBG & HTG INC01/07/2026
DOB NOWMechanical SystemsPermit IssuedPARKWAY MECHANICAL CORP12/02/2025
1 project · most recent 02/04/2026
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
02/04/2026Permit IssuedPARKWAY MECHANICAL CORPAir Conditioning Systems, Heating Systems
Cooling
Daikin HP-2, HEAT PUMP/ RXN18KEVJU 18,000 BTU · Heat Pump Outdoor ×1
HP-3, HEAT PUMP/ RXN24KEVJU 22,000 BTU · Heat Pump Outdoor ×1
Goodman CU-1, CONDENSER/ VSX13060IBB 60,000 BTU · Condensing Unit ×1
CU-2, CONDENSER / GSX130601BA 60,000 BTU · Condensing Unit ×1
Comfort Aire HP-1, HEAT PUMP/ A-DVHI8SF-1 18,000 BTU · Heat Pump Outdoor ×1
Heating
Daikin HP-2, HEAT PUMP/ RXN18KEVJU 20,000 BTU · Heat Pump Outdoor ×1
HP-3, HEAT PUMP/ RXN24KEVJU 24,000 BTU · Heat Pump Outdoor ×1
Goodman F-1/FURNACES- GKS91155DXAG F-2/FURNACES - GKS91155DXAF 115,000 BTU · Furnace ×2
Comfort Aire HP-1, HEAT PUMP/ A-DVH18SF-1 18,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 02/04/2026
Gas
FiledStatusContractorScope
02/04/2026Permit IssuedCONTROL PLBG & HTG INCGas
1 project · most recent 02/04/2026
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
02/04/2026Permit IssuedCONTROL PLBG & HTG INCTenant Protection Plan 72 Hour
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
08/18/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/07/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/01/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/09/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/02/2026Pass-Final PL - UndergroundPassView ↗
01/22/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/22/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/13/2026Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
02/02/2026Fire-Resistant Penetrations and JointsABDALLAH ELCHERBINIspecial
02/02/2026Tenant Protection Plan Compliance—special
02/02/2026Fire-Resistant Penetrations and JointsABDALLAH ELCHERBINIspecial
02/02/2026HVAC-R and service water piping design and insulationSteven Bendoraitisenergy_progress
02/02/2026Maintenance informationSteven Bendoraitisenergy_progress
02/02/2026HVAC-R and service water heating system controlsSteven Bendoraitisenergy_progress
02/02/2026HVAC-R and service water heating equipmentSteven Bendoraitisenergy_progress
02/02/2026Heating SystemsABDALLAH ELCHERBINIspecial
01/14/2026Tenant Protection Plan ComplianceABDALLAH ELCHERBINIspecial
11/03/2025Fire-Resistant Penetrations and JointsABDALLAH ELCHERBINIspecial
11/03/2025HVAC-R and service water heating system controlsSteven Bendoraitisenergy_progress
11/03/2025HVAC-R and service water piping design and insulationSteven Bendoraitisenergy_progress
11/03/2025Maintenance informationSteven Bendoraitisenergy_progress
11/03/2025HVAC-R and service water heating equipmentSteven Bendoraitisenergy_progress
11/03/2025Energy Code Compliance InspectionsSteven Bendoraitisprogress
10/20/2025Mechanical SystemsABDALLAH ELCHERBINIspecial
10/20/2025Tenant Protection Plan ComplianceABDALLAH ELCHERBINIspecial
10/20/2025FinalSteven Bendoraitisprogress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/18/2026B01305463-P1Request digital key ↗
08/18/2026B01305463-S2Request digital key ↗
08/18/2026B01305463-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature10
09/23/2026B01305463-I1Open ↗
09/23/2026B01305463-I1Open ↗
09/23/2026B01305463-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/18/2026B01305463-P1Open ↗
08/18/2026B01305463-S2Open ↗
08/18/2026B01305463-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026B01305463-I1Open ↗
08/23/2026B01305463-P1Open ↗
08/22/2026B01305463-S2Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/18/2026B01305463-S2Open ↗
08/18/2026B01305463-S1Open ↗
08/18/2026B01305463-I1Open ↗
Showing 3 of 4 on file for this type