← Back
Predominantly retail with other uses
1691 MCDONALD AVENUE
BROOKLYN · BIN 3329177
💬 Discuss this project
1931Year Built
1Stories
K4Building Class
M1-1Zoning
11,100 sfGross Floor Area
5Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Predominantly retail with other uses · Owner of record: KING TOWERS, LLC · 8,000 sf lot · 1.39 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Roof1p · 1 filing · 6 docs
Floor 12p · 2 filings · 18 docs
Cellar1p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KINGS TOWERS LLC1503/22/2026
RESTAURANT103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SOTIR ASSOCIATES508/02/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HAMOUD CONSTRUCTION CORPGeneral Contractor303/21/2026
SUPERIOR PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SOTIR ASSOCIATES7473208/02/2023
Building Lifecycle
All (20)Filed (5)Permit Issued (2)Violation (4)Inspection (3)Special Inspection (6)
01/29/2026
Violation issued (FDNY_NOV, closed)
08/03/2023
Special inspection requirement — Mechanical Systems
Hany Demetry
08/03/2023
Special inspection requirement — Energy Code Compliance Inspections
Hany Demetry
08/03/2023
Special inspection requirement — Final
Hany Demetry
08/02/2023
Filed — Alteration
FILING TO OBTAIN EQ. PERMIT FOR EXISTING OUTDOOR EXHAUST FAN ON ROOF & TO LEGALIZE THE 1ST FLOOR COMMERCIAL KITCHEN HOOD & EXHAUST SYSTEM.
B00875943-P1
06/20/2023
Permit issued — Mechanical Systems
B00875943-I1-MS
05/26/2023
Filed — Alteration
FILING TO OBTAIN EQ. PERMIT FOR EXISTING OUTDOOR EXHAUST FAN ON ROOF & TO LEGALIZE THE 1ST FLOOR COMMERCIAL KITCHEN HOOD & EXHAUST SYSTEM.
B00875943-I1
06/17/2022
Filed — Alteration
PROPOSED NEW COMMERCIAL COOKING EQUIPMENT & REPAIR PLUMBING PIPING IN EXISTING 1ST FLOOR COMMERCIAL KITCHEN.
B00690345-P2
06/17/2022
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
06/16/2022
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
05/04/2022
Filed — Alteration
PROPOSED NEW COMMERCIAL COOKING EQUIPMENT & REPAIR PLUMBING PIPING IN EXISTING 1ST FLOOR COMMERCIAL KITCHEN.
B00690345-P1
05/04/2022
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
04/22/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/15/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/15/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/05/2022
Permit issued — Plumbing
B00690345-I1-PL
03/31/2022
Filed — Alteration
PROPOSED NEW COMMERCIAL COOKING EQUIPMENT & REPAIR PLUMBING PIPING IN EXISTING 1ST FLOOR COMMERCIAL KITCHEN.
B00690345-I1
10/19/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/16/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/16/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedHAMOUD CONSTRUCTION CORP06/20/2023
DOB NOWPlumbingSigned-offSUPERIOR PLUMBING & HEATI04/05/2022
1 job · most recent 06/17/2022
Gas Water/Sanitary
FiledStatusContractorScope
06/17/2022Signed-offSUPERIOR PLUMBING & HEATIGas, Water/Sanitary
1 job · most recent 10/21/2025
FiledStatusContractorScope
10/21/2025Permit IssuedASCUATECH ELECTRICAL CORP1 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
04/22/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/15/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/15/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
08/03/2023Mechanical SystemsHany Demetryspecial
08/03/2023Energy Code Compliance InspectionsHany Demetryprogress
08/03/2023FinalHany Demetryprogress
06/17/2022Energy Code Compliance InspectionsPAUL MARINOprogress
06/16/2022Energy Code Compliance InspectionsPAUL MARINOprogress
05/04/2022Energy Code Compliance InspectionsPAUL MARINOprogress
▾Documents — 36 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/30/2026B00690345-P1Request digital key ↗
08/30/2026B00690345-P2Request digital key ↗
08/30/2026B00690345-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
01/05/2023320869949Open ↗
12/28/2013320869949Open ↗
▸Seals & Professional Certifications14
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/30/2026B00690345-P1Open ↗
08/30/2026B00690345-I1Open ↗
08/27/2026B00875943-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/02/2026B00690345-P2Open ↗
09/01/2026B00690345-P1Open ↗
09/01/2026B00875943-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
06/06/2019321961560Open ↗
12/28/2013320869949Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/06/2019321961560Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/06/2019321961560Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026B00875943-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
12/28/2013320869949Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/30/2026B00690345-I1Open ↗
08/30/2026B00690345-P1Open ↗
08/13/2026B00690345-P2Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/28/2013320869949Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
10/07/2019321961560Open ↗
10/01/2019321961560Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
06/18/2015320869949Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
10/07/2019321961560Open ↗
06/06/2019321961560Open ↗
12/28/2013320869949Open ↗
▸Filing & Intake Forms4
▸BISBOROUGH INTAKE FORM2
10/07/2019321961560Open ↗
10/07/2019321961560Open ↗
▸BISEFILING COVER SHEET2
06/06/2019321961560Open ↗
12/28/2013320869949Open ↗