← Back
General warehouse
161 GARDNER AVENUE
BROOKLYN · BIN 3330363
💬 Discuss this project
1968Year Built
1Stories
E1Building Class
M3-1Zoning
13,704 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
General warehouse · Owner of record: ADVANCE & EXCEL, LLC · 13,704 sf lot · 1 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanical
Roof2p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SEUNG JU INTERNATIONAL CORP203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BILLAH ENGINEERING PLLC205/26/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YILIN CONSTRUCTION INCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BILLAH ENGINEERING5838205/26/2021
Building Lifecycle
All (9)Filed (2)Permit Issued (1)Violation (2)Special Inspection (4)
12/06/2024
Violation issued (ECB, open)
Construction
05/28/2021
Special inspection requirement — Mechanical Systems
MOHAMMAD BILLAH
05/28/2021
Special inspection requirement — Final
MOHAMMAD BILLAH
05/26/2021
Filed — Alteration
INSTALL (4) NEW COOLER AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00457484-P1
05/26/2021
Special inspection requirement — Mechanical Systems
MOHAMMAD BILLAH
05/26/2021
Special inspection requirement — Final
MOHAMMAD BILLAH
01/26/2021
Permit issued — Mechanical Systems
B00457484-I1-MS
01/20/2021
Filed — Alteration
INSTALL (4) NEW COOLER AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00457484-I1
05/10/1993
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offYILIN CONSTRUCTION INC01/26/2021
BISMHISSUEDA A DIVERSIFIED H C A C & R INC11/12/2002
BISPLISSUEDKAPNAG HTG & PLBG CORP.10/26/2000
BISOTISSUEDAETNA MAINTENANCE08/30/2000
1 project · most recent 05/26/2021
Refrigeration Systems
FiledStatusContractorScopeMake / Model / Capacity
05/26/2021Signed-offYILIN CONSTRUCTION INCRefrigeration Systems
Refrigeration
Krack VSC2533ZX THM 230 kW · Condensing Unit ×18
Hearcraft BD10751H2C 230 kW · Condensing Unit ×4
Russell DLD10H22-E 230 kW · Condensing Unit ×4
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
05/28/2021Mechanical SystemsMOHAMMAD BILLAHspecial
05/28/2021FinalMOHAMMAD BILLAHprogress
05/26/2021Mechanical SystemsMOHAMMAD BILLAHspecial
05/26/2021FinalMOHAMMAD BILLAHprogress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Mechanical Systems2
09/01/2026B00457484-I1Request digital key ↗
08/15/2026B00457484-P1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00457484-P1Open ↗
08/13/2026B00457484-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B00457484-P1Open ↗
08/24/2026B00457484-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B00457484-P1Open ↗
08/24/2026B00457484-I1Open ↗