DOB05/08/2026FAILURE TO COMPLY COMMISSIONER'S ORDER CONTAINED IN VIOLATION 041526CE30101ML (CONTROL 376486) ISSUED 4/15/2026. REMEDY: COMPLY WITH AFOREMENTIONED COMMISSIONER'S ORDER. PROVIDE ALL REQUESTED DOCUMENTS
ECB01/23/2026AT THE TIME OF MY INSPECTION-OBSERVED HORIZONTAL BRACING INSTALLED AT EXP#1,2,4 ON ADJ PROPERTY 1ST FLOOR LEVEL,AND FRONT EXP#1 BUILDING WALL-OBSERVED STRUCTURE INSTALLED AT EXP#1 ON JOISTS/POSTS-UPPON ASKING F$2K due
ECB01/23/2026OBSERVED WORK CONTRARY TO PLANS-MISSING RAKERS(EXP#1,2,4)-MISSING HORIZONTAL BRACING(EXP#1/2 AND EXP#1/4)-MISSING BOLTS/NUTS ON RAKERS TO WALERS CONNECTION,,NO OPTICAL MONITORING PLAN PROVIDED AS PER PLAN-CREA$2K due
ECB05/22/2024ATOI OBSERVED APPROX. 110 LINER FEAT SWS IN PLACE AT EXPOSURE 1. PERMIT NOT POSTED ON SITE AS PER CODE 28-105.11. PERMIT # B00878259-I1-SH, POST/PROPERLY POST PERMIT$2K due
ECB05/22/2024ATOI OBSERVED APPROX 110 LINEAR FT SWS IN PLACE AT EXP 1. VERTICAL SUPPORTS @ PEDESTRIAN SIDEWALK COMPROMISED DUE TO MULTIPLE CRACKED/DAMAGED MUDSILLS. SHED MISSING HI-VIZ MARKINGS & SAFETY MEASURES AT ADJACENT$10K due
ECB05/18/2022TEMPORARY EQUIPMENT ONSITE(SWS)-EXPIRED PERMIT OBSERVED SIDEWALK SHED STILL UP AT EXPOSURE#1.TEMPORARY CONSTRUCTION EQUIPMENT REQUIRES A PERMIT AT ALL TIMES TO REMAIN INSTALLED.PERMIT IN DOBNOW#B00536365 EXPIRE$6K due
ECB01/23/2026UPON CHECKING CONSTRUCTION SUPERINTENDED LOG BOOK -LAST RECORDED ENTRY OF BEING ON SITE/CHECKING THE SITE WAS ON-12/30/25- AND WORK BEING CONDUCTED CONTINUOUSLY AFTER 12/30/25-AS PER CODE IF CS WONT BE ON SITEHearing held — result not yet published$10K proposed