← Back
Two family brick
1543 CARROLL STREET
BROOKLYN · BIN 3351649
💬 Discuss this project
1920Year Built
2Stories
B1Building Class
R4Zoning
2,400 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family brick · 3,006 sf lot · 0.8 FAR built · Flood zone X
Locations of Work
Structural
Roof2p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ENGNSOL ENGINEERING LLC203/10/2022
FUHRMANN ARCHITECTURE PLLC110/01/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RAHMANN CONTRACT CO. LTD*General Contractor907/08/2026
KAISER SANDWIPIElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ACV DESIGN LTD3864203/10/2022
Building Lifecycle
All (24)Filed (3)Permit Issued (4)Signed Off (1)Violation (1)Inspection (3)Special Inspection (12)
01/12/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/10/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
05/23/2024
Permit issued — Structural
B00596607-I1-GC-CX
01/19/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/24/2022
Signed off — Alteration
B00605794-I1
10/21/2022
Inspection — Pass-Final Fence Non-Directive 14
Pass
View inspection ↗
04/20/2022
Permit issued — General Construction
B00596607-I1-GC-CX
03/14/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
ANTHONY VILLANO
03/14/2022
Special inspection requirement — Concrete - Cast-In-Place
ANTHONY VILLANO
03/14/2022
Special inspection requirement — Masonry
ANTHONY VILLANO
03/14/2022
Special inspection requirement — Structural Steel - Details
ANTHONY VILLANO
03/14/2022
Special inspection requirement — Final
Helge Fuhrmann
03/14/2022
Special inspection requirement — Fire-Resistance Rated Construction
KAISER SANDWIPI
03/10/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
RECONSTRUCT BUILDING ENVELOPE INCLUDING SLAB-ON-GRADE FLOOR, SOLID BRICK WALLS AND ROOF ASSEMBLY OF A ONE-STORY FREESTANDING PARKING STRUCTURE ACCESSORY TO R-3 OCCUPANCY GROUP. NO CHANGE TO USE. EGRESS OR OCCUPANCY WITH THIS APPLICATION.
B00596607-P1
02/17/2022
Special inspection requirement — Concrete - Cast-In-Place
ANTHONY VILLANO
02/17/2022
Special inspection requirement — Masonry
ANTHONY VILLANO
02/17/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
ANTHONY VILLANO
02/17/2022
Special inspection requirement — Structural Steel - Details
ANTHONY VILLANO
02/17/2022
Special inspection requirement — Final
KAISER SANDWIPI
02/17/2022
Special inspection requirement — Fire-Resistance Rated Construction
KAISER SANDWIPI
01/26/2022
Permit issued — Structural
B00596607-I1-GC-CX
10/29/2021
Permit issued — Construction Fence
B00605794-I1-FN
10/21/2021
Filed — Alteration
B00605794-I1
10/01/2021
Filed — ALT-CO - New Building with Existing Elements to Remain
RECONSTRUCT BUILDING ENVELOPE INCLUDING SLAB-ON-GRADE FLOOR, SOLID BRICK WALLS AND ROOF ASSEMBLY OF A ONE-STORY FREESTANDING PARKING STRUCTURE ACCESSORY TO R-3 OCCUPANCY GROUP. NO CHANGE TO USE. EGRESS OR OCCUPANCY WITH THIS APPLICATION.
B00596607-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedRAHMANN CONTRACT CO. LTD*05/23/2024
DOB NOWGeneral ConstructionPermit IssuedRAHMANN CONTRACT CO. LTD*04/20/2022
DOB NOWStructuralPermit IssuedRAHMANN CONTRACT CO. LTD*01/26/2022
DOB NOWConstruction FenceSigned-offRAHMANN CONTRACT CO. LTD*10/29/2021
1 project · most recent 03/10/2022
Steel Concrete Masonry Wood
FiledStatusContractorScope
03/10/2022Permit IssuedRAHMANN CONTRACT CO. LTD*Steel, Concrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
06/10/2024Fail-Final General Construction Non-Directive 14FailView ↗
01/19/2023Pass-Final CND-Occupancy InspectionPassView ↗
10/21/2022Pass-Final Fence Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
03/14/2022Structural Stability – Alterations of existing buildingsANTHONY VILLANOspecial
03/14/2022Concrete - Cast-In-PlaceANTHONY VILLANOspecial
03/14/2022MasonryANTHONY VILLANOspecial
03/14/2022Structural Steel - DetailsANTHONY VILLANOspecial
03/14/2022FinalHelge Fuhrmannprogress
03/14/2022Fire-Resistance Rated ConstructionKAISER SANDWIPIprogress
02/17/2022Concrete - Cast-In-PlaceANTHONY VILLANOspecial
02/17/2022MasonryANTHONY VILLANOspecial
02/17/2022Structural Stability – Alterations of existing buildingsANTHONY VILLANOspecial
02/17/2022Structural Steel - DetailsANTHONY VILLANOspecial
02/17/2022FinalKAISER SANDWIPIprogress
02/17/2022Fire-Resistance Rated ConstructionKAISER SANDWIPIprogress
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/31/2026B00605794-I1Request digital key ↗
08/31/2026B00596607-I1Request digital key ↗
08/31/2026B00596607-P1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/31/2026B00596607-I1Open ↗
▸Seals & Professional Certifications12
▸DOB NOWSpecial Inspector Seal & Signature5
08/28/2026B00596607-P1Open ↗
08/24/2026B00596607-I1Open ↗
08/24/2026B00596607-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/28/2026B00596607-P1Open ↗
08/28/2026B00596607-P1Open ↗
08/24/2026B00596607-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/31/2026B00605794-I1Open ↗
08/31/2026B00596607-I1Open ↗
08/31/2026B00596607-P1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Sign Off1
08/31/2026B00596607-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/31/2026B00596607-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification2
08/31/2026B00596607-P1Open ↗
08/31/2026B00596607-I1Open ↗
▸DOB NOWFinal Survey1
08/31/2026B00596607-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/31/2026B00596607-I1Open ↗