DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 INTERNAL HIGH PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 INTERNAL HIGH PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 INTERNAL HIGH PRESSURE INSPECTION
DOB03/16/2020VIOLATION ISSUED - FAILURE TO FILE 2017 INTERNAL HIGH PRESSURE BOILER INSPECTION
DOB03/16/2020VIOLATION ISSUED - FAILURE TO FILE 2017 INTERNAL HIGH PRESSURE BOILER INSPECTION
DOB09/08/1989V-DOB VIOLATION - ACTIVE
ECB07/12/200651/6A CLEAVER BROOKS HIGH PRESSURE BOILER. 6A)FRONT SAFETY VALVE DID NOT LIFT AT THE SET PRESSURE OF 150 P.S.I. BUT IT LIFTED AT 180 PSI.Nothing owed — awaiting certificate of correction
ECB08/19/200450 CLEAVER BROOKS 1989 N.B. 66911 50A PLATFORM SHALL BE INSTALL AT THEEND OF STEAM DRUM TO PERMIT SAFE ACCESS TO THE INTERIOR OF THE DRUMS FOR CLEANOUTS AND INSPECTION AS PER NEW YORK STATE CODE R.14-1.10Nothing owed — awaiting certificate of correction
ECB08/19/200450 50) A PLATFORM SHALL BE INSTALLED AT THE END OF THE STEAM DRUM TO PERMIT SAFE ACCESS TO THE INTERIOR OF THE DRUMS FOR CLEANOUTS AND INSPECTION AS PER NEW YORK STATE CODE R14-1.10Nothing owed — awaiting certificate of correction
ECB08/19/200450 CLEAVER BROOK N.B. 67088. 50) A PLATFORM SHALL BE INSTALLED AT THE END OF THE STEAM DRUM TO PERMIT SAFE ACCESS TO THE INTERIOR OF THE DRUMS FOR CLEANOUTS AND INSPECTION AS PER NEW YORK STATE CODE R14-1.10Nothing owed — awaiting certificate of correction