← Back
One story retail building
436 MOTHER GASTON BOULEVARD
BROOKLYN · BIN 3427173
💬 Discuss this project
1930Year Built
1Stories
K1Building Class
R6Zoning
1,750 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story retail building · 2,500 sf lot · 0.7 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 2 filings · 10 docs
Floor 1Under Construction8p · 1 filing · 5 docs
CellarUnder Construction2p · 2 filings · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HERNANDEZ GEPTULIO 1103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RIKE TECH ASSOCIATES LLC304/07/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BLUE CITY CONSTRUCTIONGeneral Contractor208/26/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BUILDTECH ENGINEERING6369204/06/2026
Building Lifecycle
All (12)Filed (3)Permit Issued (2)Violation (1)Objection (2)Special Inspection (4)
08/18/2026
Permit issued — General Construction
B01372939-I1-GC
08/10/2026
Permit issued — Mechanical Systems
B01375936-I1-MS
05/05/2026
Objection resolved — Resolved
04/27/2026
Objection raised — Other
04/07/2026
Filed — Alteration
1.) INSTALL NEW` PLUMBING FIXTUIRES AT FIRST FLORR ONLY. a,- INSTA.LL NEW 3 CHILDREN TOILETS AND 1 STAFF TOILET b.- INSTAL 6 CHILDREN LAVATORIES, 1 STAFF LAVATORY c.- NEW SINK , SANITARY PIPING FOR NEW PLUMNG FIXTURES D.- INSTALL NEW 2" VENT",
B01375815-I1
04/06/2026
Filed — Alteration CO
NEW CERTIFICATE OF OCCUPANCY TO BE OBTAINED FOR CELLAR AND FIRST FLOOR FOR NEW DAY CARE CENTER AT FIRST FLOOR.. INTERIOR RENOVATION 1- NEW 5 " NON-BEARIING PARTITION 2- H.C RAMP OUT-SIDE AND INSIDE. 3- RECEPTION AREA AND WAITING AREA.
B01372939-I1
04/06/2026
Filed — Alteration
TO REACTIVATED EXISTING COMMERCIAL HVAC ROOF TOP UNIT : 1- REPLACE EXISTING DUCTS WOR 2.-) REPLACE DXISTING DIFUSSERS , 3.- RE PLACE RETURN GRILL
B01375936-I1
03/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/20/2026
Special inspection requirement — Mechanical Systems
Luis Pichardo
03/20/2026
Special inspection requirement — Final
RONALD VILLANO
03/20/2026
Special inspection requirement — Energy Code Compliance Inspections
Luis Pichardo
09/02/2020
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedBLUE CITY CONSTRUCTION08/18/2026
DOB NOWMechanical SystemsPermit IssuedBLUE CITY CONSTRUCTION08/10/2026
1 project · most recent 04/06/2026
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
04/06/2026Permit IssuedBLUE CITY CONSTRUCTIONAir Conditioning Systems, Heating Systems
Cooling
Carrier CARRIER - 48TCED12A2A5A0A0G0 120,000 BTU · Exhaust Fan ×1
Heating
Carrier CARRIER - 48TCED12A2A5A0AG0, 60,000 BTU · Rooftop Unit ×1
1 project · most recent 04/07/2026
Water/Sanitary
FiledStatusContractorScope
04/07/2026——Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
03/28/2026Fire-Resistant Penetrations and Joints—special
03/20/2026Mechanical SystemsLuis Pichardospecial
03/20/2026FinalRONALD VILLANOprogress
03/20/2026Energy Code Compliance InspectionsLuis Pichardoprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
09/03/2026B01375815-I1Request digital key ↗
08/17/2026B01372939-I1Request digital key ↗
08/17/2026B01375936-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026B01372939-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/03/2026B01375815-I1Open ↗
08/17/2026B01372939-I1Open ↗
08/17/2026B01375936-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/02/2026B01375936-I1Open ↗
09/02/2026B01375936-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/02/2026B01375936-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/17/2026B01372939-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
09/03/2026B01375815-I1Open ↗
08/17/2026B01372939-I1Open ↗