← Back
BROOKLYN
636 EAST 32 STREET
BROOKLYN · BIN 3429262
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof8p · 2 filings · 13 docs
Floor 48p · 2 filings · 8 docs
Floor 38p · 2 filings · 8 docs
Floor 27p · 1 filing · 6 docs
Floor 18p · 2 filings · 8 docs
Mezzanine10p · 4 filings · 18 docs
Cellar12p · 2 filings · 8 docs
1 job · most recent 12/31/2021
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
12/31/2021Permit IssuedHSK MANAGEMENT INCAir Conditioning Systems, Heating Systems
Cooling
Daikin FTXS09LVJU 7,000 BTU · Fan Coil Indoor ×16
3MXS24RMVJU 24,000 BTU · Condensing Unit ×7
4MXS36RMVJU 36,000 BTU · Condensing Unit ×5
2MXS18NMVJU 18,000 BTU · Condensing Unit ×3
5MXS48TVJU 47,000 BTU · Condensing Unit ×1
Heating
Daikin FTXS07LVJU 7,000 BTU · Fan Coil Indoor ×22
FTXS15LVJU 15,000 BTU · Fan Coil Indoor ×6
FTXS12LVJU 14,400 BTU · Fan Coil Indoor ×5
1 job · most recent 06/13/2023
FiledStatusContractorScope
06/13/2023Signed-offARCO PLBG AND HTG INC—
1 job · most recent 05/01/2023
Storm Water/Sanitary
FiledStatusContractorScope
05/01/2023Signed-offBT'S PLUMBING AND HEATINGStorm, Water/Sanitary
1 job · most recent 03/20/2023
General Wiring
FiledStatusContractorScope
03/20/2023Permit IssuedB.P. ELECTRIC CORPGeneral Wiring
1 job · most recent 10/16/2023
Scaffold
FiledStatusContractorScope
10/16/2023——Scaffold
Building Lifecycle
All (65)Filed (7)Permit Issued (9)Signed Off (2)Inspection (8)Objection (18)Special Inspection (18)Tax Incentive (3)
01/01/2027
421-a(16) construction completed
07/09/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
07/09/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/07/2026
Signed off — Alteration
B00660928-S1
07/07/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/26/2026
Permit issued — Plumbing
B60745657-I1-PL
03/18/2026
Permit issued — Plumbing
B00692251-I1-PL
03/18/2026
Permit issued — Sprinklers
B00692941-I1-EW-SP
03/06/2026
Signed off — Alteration
B00660928-I1
01/22/2026
Permit issued — Construction Fence
B00660928-S1-FN
12/19/2025
Filed — Alteration
B00660928-S1
08/28/2024
421-a(16) registration filed
01/12/2024
Objection resolved — Addressed
12/01/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/01/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/01/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/01/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/16/2023
Permit issued — Plumbing
B00692251-I1-PL
10/16/2023
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B00948467-I1
10/12/2023
Objection resolved — Addressed
10/03/2023
Permit issued — General Construction
B00660928-I1-GC-CX
09/19/2023
Objection resolved — Addressed
09/19/2023
Objection resolved — Addressed
09/18/2023
Objection resolved — Addressed
09/18/2023
Objection resolved — Addressed
09/08/2023
Objection resolved — Addressed
09/06/2023
Objection resolved — Addressed
09/06/2023
Objection resolved — Addressed
08/09/2023
Permit issued — Structural
B00660928-I1-GC-CX
06/16/2023
Objection raised — Structural
06/16/2023
Objection raised — Admin
06/16/2023
Objection raised — Fire_Protection
06/16/2023
Objection raised — Mechanical
06/16/2023
Objection raised — Structural
06/16/2023
Objection raised — Mechanical
06/16/2023
Objection raised — Structural
06/13/2023
Filed — Alteration
INSTALL FIRE SPRINKLER SYSTEM IN THE ENTIRE BUILDING I.A.W NFPA 13R 2007 EDIT, AS MODIFED NYC BC 901 APPENDIX Q 104 AS PER PLAN. NB OCCUPANCY EXISTING SHOULD BE SAME AS PROPOSED. SPRINKLER PLAN IN CONJUNCTION WITH NB APPLICATION NO. 340755392.
B00692941-I1
05/08/2023
Objection raised — Zoning
05/08/2023
Objection raised — Fire_Protection
05/01/2023
Filed — Alteration
INSTALLATION OF PIPING AND PLUMBING FIXTURES IN CONJUNCTION WITH MAIN APPLICATION #340755392-NB
B00692251-I1
05/01/2023
Special inspection requirement — Energy Code Compliance Inspections
RAUL VELASQUEZ MARTINEZ
01/09/2023
Special inspection requirement — HVAC-R and service water heating equipment
RAUL VELASQUEZ MARTINEZ
01/09/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
RAUL VELASQUEZ MARTINEZ
01/09/2023
Special inspection requirement — Maintenance information
RAUL VELASQUEZ MARTINEZ
01/09/2023
Special inspection requirement — HVAC-R and service water heating system controls
RAUL VELASQUEZ MARTINEZ
01/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
RAUL VELASQUEZ MARTINEZ
01/06/2023
Special inspection requirement — Post-installed Anchors
RAUL VELASQUEZ MARTINEZ
01/06/2023
Special inspection requirement — Seismic Isolation Systems
RAUL VELASQUEZ MARTINEZ
01/06/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
RAUL VELASQUEZ MARTINEZ
11/30/2022
Permit issued — Mechanical Systems
B00655591-I1-MS
03/07/2022
Special inspection requirement — Sprinkler Systems
RAUL VELASQUEZ MARTINEZ
02/08/2022
Permit issued — General Construction
B00660928-I1-GC-CX
02/08/2022
421-a(16) construction commenced
01/28/2022
Filed — Alteration
B00662340-I1
01/21/2022
Filed — Alteration
B00660928-I1
01/11/2022
Special inspection requirement — Concrete - Cast-In-Place
RAUL VELASQUEZ MARTINEZ
01/11/2022
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
RAUL VELASQUEZ MARTINEZ
01/11/2022
Special inspection requirement — Masonry
RAUL VELASQUEZ MARTINEZ
01/11/2022
Special inspection requirement — Structural Cold-Formed Steel
RAUL VELASQUEZ MARTINEZ
Latest 60 of 65 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HSK MANAGEMENT2207/08/2026
HOLLYWOOD CONS GROUP203/21/2026
JOINT CAPITAL DEVELOPMENT203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AL FFRED ARCHITECTURE PLLC312/19/2025
MJE PROFESSIONAL SERVICES110/16/2023
M.INT'L ENGINEERING PLLC105/01/2023
BGM ENGINEERING201/28/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EMPIRE EXPEDITING1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KISHAN PLUMBING INCPlumbing707/08/2026
HSK MANAGEMENT INCGeneral Contractor304/09/2026
ACE MAINTENANCE USA LLCGeneral Contractor107/08/2026
HOLLYWOOD CONS. GROUP INCGeneral Contractor104/09/2026
MOSHE ROTHElectrical103/21/2026
BT'S PLUMBING AND HEATINGPlumbing107/08/2026
JUST PLBG & HTG INCPlumbing107/08/2026
ARCO PLBG AND HTG INCFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BGM ENGINEERING, LLC1514406/13/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJUST PLBG & HTG INC06/26/2026
DOB NOWPlumbingSigned-offBT'S PLUMBING AND HEATING03/18/2026
DOB NOWSprinklersSigned-offARCO PLBG AND HTG INC03/18/2026
DOB NOWConstruction FenceSigned-offACE MAINTENANCE USA LLC01/22/2026
DOB NOWPlumbingPermit IssuedN AND S PLUMBING INC11/16/2023
DOB NOWGeneral ConstructionSigned-offHOLLYWOOD CONS. GROUP INC10/03/2023
DOB NOWStructuralSigned-offHSK MANAGEMENT INC08/09/2023
DOB NOWMechanical SystemsPermit IssuedHSK MANAGEMENT INC11/30/2022
DOB NOWGeneral ConstructionSigned-offHSK MANAGEMENT INC02/08/2022
BIS—ISSUEDACE MAINTENANCE USA LLC03/10/2026
BIS—ISSUEDACE MAINTENANCE USA LLC03/10/2026
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
07/09/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
07/09/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/07/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/07/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/01/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/01/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/01/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/01/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
05/01/2023Energy Code Compliance InspectionsRAUL VELASQUEZ MARTINEZprogress
01/09/2023HVAC-R and service water heating equipmentRAUL VELASQUEZ MARTINEZenergy_progress
01/09/2023HVAC-R and service water piping design and insulationRAUL VELASQUEZ MARTINEZenergy_progress
01/09/2023Maintenance informationRAUL VELASQUEZ MARTINEZenergy_progress
01/09/2023HVAC-R and service water heating system controlsRAUL VELASQUEZ MARTINEZenergy_progress
01/09/2023Fire-Resistant Penetrations and JointsRAUL VELASQUEZ MARTINEZspecial
01/06/2023Post-installed AnchorsRAUL VELASQUEZ MARTINEZspecial
01/06/2023Seismic Isolation SystemsRAUL VELASQUEZ MARTINEZspecial
01/06/2023Fire-Resistant Penetrations and JointsRAUL VELASQUEZ MARTINEZspecial
03/07/2022Sprinkler SystemsRAUL VELASQUEZ MARTINEZspecial
01/11/2022Concrete - Cast-In-PlaceRAUL VELASQUEZ MARTINEZspecial
01/11/2022Excavations - Sheeting, Shoring, and BracingRAUL VELASQUEZ MARTINEZspecial
01/11/2022MasonryRAUL VELASQUEZ MARTINEZspecial
01/11/2022Structural Cold-Formed SteelRAUL VELASQUEZ MARTINEZspecial
01/11/2022Structural Steel - DetailsRAUL VELASQUEZ MARTINEZspecial
01/11/2022Subgrade InspectionsRAUL VELASQUEZ MARTINEZspecial
01/11/2022FinalRAUL VELASQUEZ MARTINEZprogress
01/11/2022Footing and FoundationRAUL VELASQUEZ MARTINEZprogress
▾Documents — 91 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/31/2026B00655591-I1Request digital key ↗
08/31/2026B00662340-I1Request digital key ↗
08/27/2026B00692941-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits23
▸BISPLAN / WORK APPROVAL APPLICATION20
12/04/2025340892190Open ↗
07/30/2024340755392Open ↗
03/05/2024340755392Open ↗
Showing 3 of 20 on file for this type
▸BISWORK PERMIT APPLICATION2
02/17/2026340755392Open ↗
12/16/2025340755392Open ↗
▸BISWITHDRAW DOC02 PRIOR TO PERMIT1
10/13/2021340755392Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
03/19/2021340755392Open ↗
▸BISZONING DIAGRAM1
03/19/2021340755392Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
03/19/2021340755392Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
01/13/2022340755392Open ↗
▸Seals & Professional Certifications17
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/31/2026B00662340-I1Open ↗
08/27/2026B00692941-I1Open ↗
08/19/2026B00660928-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026B00660928-I1Open ↗
08/24/2026B00692251-I1Open ↗
08/24/2026B00692941-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026B00660928-I1Open ↗
08/24/2026B00692251-I1Open ↗
08/24/2026B00692251-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE2
08/11/2023340892190Open ↗
09/22/2020340755392Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
09/25/2023340892190Open ↗
09/22/2020340755392Open ↗
▸Trade Schedules & Equipment1
▸BISDEP SANITARY SEWER CERTIFICATION (HCP/SCP)1
03/19/2021340755392Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST2
08/11/2023340892190Open ↗
11/18/2020340755392Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
09/21/2021340755392Open ↗
▸BISBPP: STREET TREES SITE PLAN1
08/21/2023340892190Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
10/13/2021340755392Open ↗
09/21/2021340755392Open ↗
02/05/2021340755392Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/14/2026B00692251-I1Open ↗
▸Inspections & Test Reports8
▸BISTECHNICAL REPORT: RESPONSIBILITY5
10/13/2021340755392Open ↗
09/21/2021340755392Open ↗
03/19/2021340755392Open ↗
Showing 3 of 5 on file for this type
▸BISSOIL REPORT1
03/19/2021340755392Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
03/19/2021340755392Open ↗
▸BISDEMOLITION (DM) JOB SIGNOFF1
09/21/2021340755392Open ↗
▸Approvals, Objections & Sign-offs5
▸BISSCHEDULE A - OCCUPANCY / USE3
07/05/2023340755392Open ↗
02/19/2021340755392Open ↗
01/27/2021340755392Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
12/16/2025340755392Open ↗
▸DOB NOWDCLA Approval of Artwork1
08/13/2026B00660928-S1Open ↗
▸Cost, Insurance & Ownership3
▸BISPROJECT-SPECIFIC GL INSURANCE3
12/16/2025340755392Open ↗
07/23/2024340755392Open ↗
10/13/2021340755392Open ↗
▸Filing & Intake Forms6
▸BISEFILING JOB APPLICATION COVER SHEET2
08/11/2023340892190Open ↗
09/22/2020340755392Open ↗
▸BISEFILING COVER SHEET1
03/10/2021340755392Open ↗
▸BISADDITIONAL INFORMATION1
08/21/2023340892190Open ↗
▸BISBOROUGH INTAKE FORM1
12/16/2025340755392Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
08/11/2023340892190Open ↗
▸Other Documents9
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION5
12/16/2025340755392Open ↗
03/19/2021340755392Open ↗
03/19/2021340755392Open ↗
Showing 3 of 5 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION1
08/21/2023340892190Open ↗
▸BISPLOT DIAGRAM1
11/18/2020340755392Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
09/22/2020340755392Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00662340-I1Open ↗