| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/06/2026 | Permit Issued | H BUILDING MANAGEMENT INC | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MSZ-GX09NL & MSZ-FX18NL 91,800 BTU · Fan Coil Indoor ×8 MSZ-GX12NL & MSZ-GX06NL 52,800 BTU · Fan Coil Indoor ×8 MSZ-GX12NL 52,800 BTU · Fan Coil Indoor ×4 MXZ-SM48NLHZ 102,000 BTU · Condensing Unit ×4 MSZ-FX18NL & MSZ-GX09NL 72,400 BTU · Fan Coil Indoor ×3 MXZ-SM36NLHZ 78,000 BTU · Condensing Unit ×2 MLZ-KX09NL 21,000 BTU · Fan Coil Indoor ×1 SUZ-AA09NL 21,000 BTU · Pump ×1 Mi MSZ-GX06NL & MSZ-GX09NL 32,400 BTU · Fan Coil Indoor ×4 Ventilation |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/06/2026 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/06/2026 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/06/2026 | Permit Issued | H BUILDING MANAGEMENT INC | Steel, Concrete, Masonry |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/06/2026 | Permit Issued | H BUILDING MANAGEMENT INC | Fence |
| Owner | Filings | Most Recent |
|---|---|---|
| FIRERUSH | 2 | 09/13/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| YAN ENGINEERING PLLC | 3 | 05/06/2026 |
| IVAN SHCHERBAKOV | 3 | 03/25/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Construction Fence | Permit Issued | H BUILDING MANAGEMENT INC | 03/17/2026 |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/14/2026 | Metering | — | energy_progress |
| 05/14/2026 | Maintenance information | — | energy_progress |
| 05/04/2026 | Subsurface Investigations (Borings/Test Pits) | — | special |
| 05/04/2026 | Subgrade Inspections | — | special |
| 04/14/2026 | Excavations - Sheeting, Shoring, and Bracing | — | special |
| 04/14/2026 | Concrete - Cast-In-Place | — | special |
| 04/14/2026 | Structural Steel - High Strength Bolting | — | special |
| 04/14/2026 | Structural Steel - Welding | — | special |
| 04/14/2026 | Masonry | — | special |
| 04/14/2026 | Structural Cold-Formed Steel | — | special |
| 04/14/2026 | Structural Steel - Details | — | special |
| 04/06/2026 | Final | — | progress |
| 12/03/2025 | Air barrier — testing | — | energy_progress |
| 12/03/2025 | Exterior Insulation and Finish Systems (EIFS) | — | special |
| 12/03/2025 | Protection of exposed foundation insulation | — | energy_progress |
| 12/03/2025 | Interior lighting power | — | energy_progress |
| 12/03/2025 | Air barrier - visual inspection | — | energy_progress |
| 12/03/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 12/03/2025 | Energy Code Compliance Inspections | — | progress |
| 12/03/2025 | Fire-Resistance Rated Construction | — | progress |
| 12/03/2025 | Preliminary | — | progress |
| 12/03/2025 | Exterior lighting power | — | energy_progress |
| 12/03/2025 | Fenestration air leakage | — | energy_progress |
| 12/03/2025 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 12/03/2025 | Lighting controls | — | energy_progress |