← Back
Zoned commercial or Manhattan residential
VAN BRUNT STREET
BROOKLYN · BIN 3829723
💬 Discuss this project
0Year Built
—Stories
V1Building Class
M1-1/R5Zoning
0 sfGross Floor Area
0Units
Zoned commercial or Manhattan residential · Owner of record: OFFICE OF URBAN TERRAINS LLC · 1,725 sf lot · 0 FAR built · Flood zone AE
Locations of Work
Mechanical
Roof1p · 1 filing · 16 docs
Floor 31p · 1 filing · 16 docs
Floor 21p · 1 filing · 16 docs
Floor 11p · 1 filing · 16 docs
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J CALLAHAN CONSULTING1203/21/2026
Building Lifecycle
All (53)Filed (7)Objection (16)Special Inspection (30)
08/03/2026
Special inspection requirement — Concrete - Cast-In-Place
08/03/2026
Special inspection requirement — Subgrade Inspections
08/03/2026
Special inspection requirement — Deep Foundation Elements
08/03/2026
Special inspection requirement — Footing and Foundation
08/03/2026
Special inspection requirement — Final
07/10/2026
Filed — New Building
Herewith filing structural work, as per plans submitted, in conjunction with NB# B01200628, two (2) buildings on one (1) zoning lot.
B01211023-P1
07/10/2026
Special inspection requirement — Final
07/10/2026
Special inspection requirement — Footing and Foundation
07/10/2026
Special inspection requirement — Concrete - Cast-In-Place
07/10/2026
Special inspection requirement — Deep Foundation Elements
07/10/2026
Special inspection requirement — Subgrade Inspections
05/21/2025
Objection raised — Admin
05/21/2025
Objection raised — Energy
05/21/2025
Objection raised — Scope
05/21/2025
Objection raised — Admin
05/21/2025
Objection raised — Admin
05/21/2025
Objection raised — Structural
05/21/2025
Objection raised — Structural
05/21/2025
Objection raised — Inspections
05/21/2025
Objection raised — Zoning
05/20/2025
Objection raised — Other
05/16/2025
Objection raised — Other
05/16/2025
Objection raised — Other
05/16/2025
Objection raised — Scope
05/16/2025
Objection raised — Inspections
05/16/2025
Objection raised — Structural
05/16/2025
Objection raised — Energy
05/12/2025
Filed — New Building
Herewith filing structural work, as per plans submitted, in conjunction with NB# B01200628, two (2) buildings on one (1) zoning lot.
B01211023-S1
05/12/2025
Filed — New Building
Herewith filing structural work, as per plans submitted, in conjunction with NB# B01200628, two (2) buildings on one (1) zoning lot.
B01211023-S3
05/12/2025
Filed — New Building
Herewith filing structural work, as per plans submitted, in conjunction with NB# B01200628, two (2) buildings on one (1) zoning lot.
B01211023-S2
05/09/2025
Filed — New Building
Herewith filing structural work, as per plans submitted, in conjunction with NB# B01200628, two (2) buildings on one (1) zoning lot.
B01211023-S5
05/08/2025
Filed — New Building
Herewith filing structural work, as per plans submitted, in conjunction with NB# B01200628, two (2) buildings on one (1) zoning lot.
B01211023-S4
05/08/2025
Filed — New Building
Herewith filing structural work, as per plans submitted, in conjunction with NB# B01200628, two (2) buildings on one (1) zoning lot.
B01211023-I1
05/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/05/2025
Special inspection requirement — Insulation placement and R values
05/05/2025
Special inspection requirement — Permanent certificate
05/05/2025
Special inspection requirement — Fenestration air leakage
05/05/2025
Special inspection requirement — Electric vehicle service equipment requirements
05/05/2025
Special inspection requirement — Exterior lighting power
05/05/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
05/05/2025
Special inspection requirement — Protection of exposed foundation insulation
05/05/2025
Special inspection requirement — Interior lighting power
05/05/2025
Special inspection requirement — Maintenance information
05/05/2025
Special inspection requirement — Lighting controls
05/05/2025
Special inspection requirement — Sprinkler Systems
05/05/2025
Special inspection requirement — Structural Wood Frame
05/05/2025
Special inspection requirement — Aluminum Construction
05/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/05/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
05/05/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
05/05/2025
Special inspection requirement — Energy Code Compliance Inspections
05/05/2025
Special inspection requirement — Fire-Resistance Rated Construction
05/05/2025
Special inspection requirement — Lighting in dwelling units
Nothing on file for this building.
1 project · most recent 07/10/2026
Generators Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/10/2026——Generators, Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NAMHZ-U1 54,000 BTU · Heat Pump Outdoor ×2
Ventilation
Lifebreath HE07RT 125 CFM · Erv ×3
Generators
Generac Generac 24 kW · Generator ×1
1 project · most recent 07/10/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/10/2026——Gas, Water/Sanitary
1 project · most recent 07/10/2026
Steel Masonry Wood
FiledStatusContractorScope
07/10/2026——Steel, Masonry, Wood
▾Special Inspection Requirements (DOB NOW) — 48
DateRequirementInspectorRole
08/03/2026Concrete - Cast-In-Place—special
08/03/2026Subgrade Inspections—special
08/03/2026Deep Foundation Elements—special
08/03/2026Footing and Foundation—progress
08/03/2026Final—progress
07/10/2026Final—progress
07/10/2026Footing and Foundation—progress
07/10/2026Concrete - Cast-In-Place—special
07/10/2026Deep Foundation Elements—special
07/10/2026Subgrade Inspections—special
05/06/2025Fire-Resistant Penetrations and Joints—special
05/05/2025Insulation placement and R values—energy_progress
05/05/2025Permanent certificate—energy_progress
05/05/2025Fenestration air leakage—energy_progress
05/05/2025Electric vehicle service equipment requirements—energy_progress
05/05/2025Exterior lighting power—energy_progress
05/05/2025Fenestration and door U-factor and product ratings—energy_progress
05/05/2025Protection of exposed foundation insulation—energy_progress
05/05/2025Interior lighting power—energy_progress
05/05/2025Maintenance information—energy_progress
05/05/2025Lighting controls—energy_progress
05/05/2025Sprinkler Systems—special
05/05/2025Structural Wood Frame—progress
05/05/2025Aluminum Construction—special
05/05/2025Fire-Resistant Penetrations and Joints—special
Latest 25 of 48.
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/21/2026B01211023-S1Request digital key ↗
08/21/2026B01211023-I1Request digital key ↗
08/21/2026B01211023-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/21/2026B01211023-I1Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/21/2026B01211023-I1Open ↗
08/21/2026B01211023-P1Open ↗
08/21/2026B01211023-S5Open ↗
Showing 3 of 7 on file for this type
▸Other Documents1
▸DOB NOWSite Survey: Initial1
08/21/2026B01211023-I1Open ↗