← Back
Five to six families
47-09 VERNON BOULEVARD
QUEENS · BIN 4000345
💬 Discuss this project
1901Year Built
3Stories
C2Building Class
R6AZoning
4,125 sfGross Floor Area
6Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Five to six families · 2,500 sf lot · 1.65 FAR built · Flood zone X500
Locations of Work
ArchitectureStructural
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 20 docs
BulkheadUnder Construction2p · 1 filing · 20 docs
Floor 5Under Construction4p · 1 filing · 20 docs
Floor 4Under Construction3p · 1 filing · 20 docs
Floor 3Under Construction8p · 2 filings · 20 docs
Floor 2Under Construction5p · 2 filings · 20 docs
Floor 1Under Construction3p · 1 filing · 3 docs
CellarUnder Construction7p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MORTAR GROUP1209/13/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JIAN ENGINEERING PLLC305/13/2026
MORTAR ARCHITECTURE PLLC405/12/2026
ALL CITY ENGINEERING P.C.312/05/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CAVALRY403/21/2026
SD DESIGN STUDIO403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ST TONE MANAGEMENT INCGeneral Contractor204/09/2026
Building Lifecycle
All (72)Filed (10)Permit Issued (2)Violation (7)Objection (23)Special Inspection (30)
07/16/2026
Objection resolved — Addressed
05/28/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
05/28/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
05/28/2026
Special inspection requirement — Demolition
05/28/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
05/28/2026
Special inspection requirement — Air barrier — testing
05/28/2026
Special inspection requirement — Fenestration air leakage
05/28/2026
Special inspection requirement — Preliminary
05/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/28/2026
Special inspection requirement — Concrete - Cast-In-Place
05/28/2026
Special inspection requirement — Masonry
05/28/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
05/28/2026
Special inspection requirement — Insulation placement and R values
05/28/2026
Special inspection requirement — Fire-Resistance Rated Construction
05/28/2026
Special inspection requirement — Fenestration areas
05/28/2026
Special inspection requirement — Air barrier - visual inspection
05/28/2026
Special inspection requirement — Energy Code Compliance Inspections
05/21/2026
Objection raised — Other
05/14/2026
Violation issued (ECB, closed)
Unknown
05/13/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Install new plumbing fixtures as per plan. There is no change of use, egress, or occupancy filed under this plan.
Q01300801-S6
05/12/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Install new plumbing fixtures as per plan. There is no change of use, egress, or occupancy filed under this plan.
Q01300801-P1
05/12/2026
Special inspection requirement — Masonry
05/12/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
05/12/2026
Special inspection requirement — Fenestration areas
05/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/12/2026
Special inspection requirement — Energy Code Compliance Inspections
05/12/2026
Special inspection requirement — Air barrier - visual inspection
05/12/2026
Special inspection requirement — Demolition
05/12/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
05/12/2026
Special inspection requirement — Preliminary
05/12/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
05/12/2026
Special inspection requirement — Concrete - Cast-In-Place
05/12/2026
Special inspection requirement — Fire-Resistance Rated Construction
05/12/2026
Special inspection requirement — Fenestration air leakage
05/12/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
05/07/2026
Violation issued (HPD, open)
A
04/28/2026
Objection resolved — Resolved
04/28/2026
Objection resolved — Resolved
04/07/2026
Objection resolved — Addressed
03/16/2026
Permit issued — Construction Fence
Q01300801-S7-FN
03/11/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Install new plumbing fixtures as per plan. There is no change of use, egress, or occupancy filed under this plan.
Q01300801-S7
02/24/2026
Objection raised — Admin
02/23/2026
Permit issued — General Construction
Q01315208-I1-GC
02/13/2026
Objection raised — Scope
02/13/2026
Objection resolved — Addressed
02/04/2026
Objection raised — Admin
02/04/2026
Objection raised — Cost
01/22/2026
Objection resolved — Addressed
01/22/2026
Objection resolved — Addressed
01/20/2026
Filed — Alteration
PROPOSE INTERIOR DEMOLITION OF FINISHES & PARTITION WORKS AS PER PLAN OF EXISTING BUILDING. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
Q01315208-I1
01/14/2026
Objection resolved — Addressed
01/09/2026
Objection raised — Zoning
01/09/2026
Objection raised — Structural
01/08/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Install new plumbing fixtures as per plan. There is no change of use, egress, or occupancy filed under this plan.
Q01300801-S5
01/08/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Install new plumbing fixtures as per plan. There is no change of use, egress, or occupancy filed under this plan.
Q01300801-S4
01/05/2026
Objection raised — Admin
12/30/2025
Objection raised — Admin
12/30/2025
Objection raised — Scope
12/12/2025
Objection resolved — Addressed
12/12/2025
Objection resolved — Addressed
Latest 60 of 72 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedST TONE MANAGEMENT INC03/16/2026
DOB NOWGeneral ConstructionPermit IssuedST TONE MANAGEMENT INC02/23/2026
BISBLISSUEDNEW YORK HEATING COMPANY03/26/2007
BISBLISSUEDECONOMY FUEL OIL INC05/18/2006
BISFBISSUEDSKAGGS & WALSH INC.07/09/1991
1 project · most recent 05/13/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/13/2026Permit IssuedST TONE MANAGEMENT INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM36NLHZ 36,000 BTU · Condensing Unit ×11
MXZ-SM48NLHZ 48,000 BTU · Condensing Unit ×4
MXZ-SM42NLHZ 42,000 BTU · Condensing Unit ×3
PUZ-AK12NL 12,200 BTU · Condensing Unit ×1
Ventilation
Greenheck USF-08-B3 600 CFM · Exhaust Fan ×4
SP-LP0511 50 CFM · Exhaust Fan ×1
USF-10-B2 1,200 CFM · Exhaust Fan ×1
USF-10-B5 600 CFM · Exhaust Fan ×1
Renewaire HE20RT 875 CFM · Erv ×1
HE2XRT 885 CFM · Erv ×1
1 project · most recent 05/13/2026
Sprinkler System
FiledStatusContractorScope
05/13/2026——Sprinkler System
1 project · most recent 05/13/2026
Storm Water/Sanitary
FiledStatusContractorScope
05/13/2026——Storm, Water/Sanitary
1 project · most recent 05/13/2026
Steel Concrete Masonry
FiledStatusContractorScope
05/13/2026Permit IssuedST TONE MANAGEMENT INCSteel, Concrete, Masonry
▾Special Inspection Requirements (DOB NOW) — 63
DateRequirementInspectorRole
05/28/2026Excavations - Sheeting, Shoring, and Bracing—special
05/28/2026Air barrier — testing —energy_progress
05/28/2026Fenestration areas—energy_progress
05/28/2026Air barrier - visual inspection—energy_progress
05/28/2026Fenestration and door U-factor and product ratings—energy_progress
05/28/2026Insulation placement and R values—energy_progress
05/28/2026Fenestration air leakage—energy_progress
05/28/2026Fire-Resistance Rated Construction—progress
05/28/2026Energy Code Compliance Inspections—progress
05/28/2026Preliminary—progress
05/28/2026Fire-Resistant Penetrations and Joints—special
05/28/2026Demolition—special
05/28/2026Concrete - Cast-In-Place—special
05/28/2026Masonry—special
05/28/2026Exterior Insulation and Finish Systems (EIFS)—special
05/28/2026Structural Stability – Alterations of existing buildings—special
05/12/2026Excavations - Sheeting, Shoring, and Bracing—special
05/12/2026Concrete - Cast-In-Place—special
05/12/2026Demolition—special
05/12/2026Excavations - Sheeting, Shoring, and Bracing—special
05/12/2026Exterior Insulation and Finish Systems (EIFS)—special
05/12/2026Fire-Resistant Penetrations and Joints—special
05/12/2026Masonry—special
05/12/2026Structural Stability – Alterations of existing buildings—special
05/12/2026Energy Code Compliance Inspections—progress
Latest 25 of 63.
▾Documents — 48 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/18/2026Q01300801-S1Request digital key ↗
08/18/2026Q01300801-S2Request digital key ↗
08/18/2026Q01300801-S3Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/18/2026Q01300801-P1Open ↗
08/13/2026Q01300801-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/18/2026Q01300801-P1Open ↗
08/13/2026Q01300801-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01300801-I1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/18/2026Q01300801-S6Open ↗
08/18/2026Q01300801-P1Open ↗
08/17/2026Q01315208-I1Open ↗
Showing 3 of 10 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/18/2026Q01300801-P1Open ↗
08/13/2026Q01300801-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/18/2026Q01300801-I1Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/18/2026Q01300801-P1Open ↗
08/18/2026Q01300801-S1Open ↗
08/18/2026Q01300801-S2Open ↗
Showing 3 of 10 on file for this type
▸Inspections & Test Reports4
▸DOB NOWTR4 Test Report and Plot Diagram2
08/14/2026Q01300801-S6Open ↗
08/13/2026Q01300801-S4Open ↗
▸DOB NOWSOIL REPORT2
08/14/2026Q01300801-S6Open ↗
08/13/2026Q01300801-S4Open ↗
▸Other Documents6
▸DOB NOWProperty Ownership Certification2
08/18/2026Q01300801-P1Open ↗
08/13/2026Q01300801-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/18/2026Q01300801-P1Open ↗
08/13/2026Q01300801-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/18/2026Q01300801-P1Open ↗
08/13/2026Q01300801-I1Open ↗