← Back
Factory, industrial, miscellaneous
21-07 BORDEN AVENUE
QUEENS · BIN 4000530
💬 Discuss this project
1907Year Built
6Stories
F9Building Class
M3-2Zoning
67,500 sfGross Floor Area
1Units
LL97 Covered3 Open Violations 0 unresolved · 3 paperwork only ▸
Factory, industrial, miscellaneous · Owner of record: FEIN BROS REAL ESTATE · 13,500 sf lot · 5 FAR built · Flood zone AE
Locations of Work
Mechanical
Roof1p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FEIN BROTHERS REAL ESTATE403/22/2026
FEINB BROS REAL ESTATE803/22/2026
REIN BROS REAL ESTATE103/22/2026
TKR MANAGEMENT LDT103/22/2026
FEIN BROS REALTY103/22/2026
PEIN BROTHERS CORP.103/22/2026
ROSE DAVIS MANAGEMENT103/22/2026
SKYWORX CONTRACTING203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW AGE ENGINEERING PLLC208/21/2026
NEW YORK ENGINEERING ASSOC., P.C.103/19/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW YORK ENGINEERING ASSOCIATES P203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
THE METRO GROUP, INCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW YORK ENGINEERING ASSO851103/19/2021
Building Lifecycle
All (74)Filed (3)Permit Issued (1)Signed Off (1)Violation (60)Special Inspection (9)
08/21/2026
Filed — Alteration
PLUMBING MODIFICATIONS TO EXISTING PLUMBING AS PER PLANS. FILING TO ADDRESS VIOLATION# 39089786H. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q01438523-I1
08/21/2026
Filed — Alteration
PLUMBING MODIFICATIONS TO EXISTING PLUMBING AS PER PLANS. FILING TO ADDRESS VIOLATION# 39089786H. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q01438523-S1
08/21/2026
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
Stephen Shishko
08/21/2026
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
Stephen Shishko
07/30/2026
Special inspection requirement — Final
Stephen Shishko
05/02/2025
Violation issued (ECB, open)
Construction
07/06/2023
Violation issued (ECB, open)
Construction
07/06/2023
Violation issued (ECB, open)
Construction
04/22/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/21/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/20/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/22/2021
Signed off — Alteration
REPLACE A/C SPLIT SYSTEM AS PER PLANS.
Q00488708-I1
04/05/2021
Permit issued — Mechanical Systems
Q00488708-I1-MS
03/19/2021
Filed — Alteration
REPLACE A/C SPLIT SYSTEM AS PER PLANS.
Q00488708-I1
03/18/2021
Special inspection requirement — HVAC-R and service water heating system controls
LOUIS ARENA
03/18/2021
Special inspection requirement — Maintenance information
LOUIS ARENA
03/18/2021
Special inspection requirement — HVAC-R and service water heating equipment
LOUIS ARENA
03/18/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
LOUIS ARENA
03/18/2021
Special inspection requirement — Mechanical Systems
LOUIS ARENA
03/18/2021
Special inspection requirement — Final
LOUIS ARENA
04/04/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/19/2018
Violation issued (ECB, closed)
Construction
09/15/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/15/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/03/2017
Violation issued (ECB, closed)
Elevators
01/03/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/01/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/18/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/18/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/14/2013
Violation issued (ECB, closed)
Elevators
06/14/2013
Violation issued (ECB, closed)
Elevators
01/30/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/30/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/03/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/18/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/01/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/11/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/11/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/10/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/10/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/11/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/11/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/07/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/07/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/06/2007
Violation issued (ECB, closed)
Elevators
07/12/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
07/12/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/28/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/28/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/03/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/26/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/26/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/03/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/03/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Latest 60 of 74 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offTHE METRO GROUP, INC04/05/2021
BISOTISSUEDMILESTONE RESTORATION INC11/23/2016
BISEQISSUEDSKYWORX CONTRACTING INC10/08/2015
BISEQISSUEDSKYWORX CONTRACTING INC09/23/2014
BISFBISSUEDDENNIS LEDUC12/20/1996
BISMHISSUEDS B MECHANICAL CORPORATION05/09/1990
3 projects · most recent 01/20/2026
General Wiring
FiledStatusContractorScope
01/20/2026CompleteAL-LECTRIC ELECT'L CONTRGGeneral Wiring
10/20/2021CompleteRESPONSE ELECTRIC INC.General Wiring
08/06/2020CompleteWILLDAN ELECTRICAL OF NYGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
08/21/2026Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)Stephen Shishkospecial
08/21/2026Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)Stephen Shishkospecial
07/30/2026FinalStephen Shishkoprogress
03/18/2021HVAC-R and service water heating system controlsLOUIS ARENAenergy_progress
03/18/2021Maintenance informationLOUIS ARENAenergy_progress
03/18/2021HVAC-R and service water heating equipmentLOUIS ARENAenergy_progress
03/18/2021HVAC-R and service water piping design and insulationLOUIS ARENAenergy_progress
03/18/2021Mechanical SystemsLOUIS ARENAspecial
03/18/2021FinalLOUIS ARENAprogress
▾Documents — 52 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/27/2026Q00488708-I1Request digital key ↗
08/22/2026Q01438523-S1Request digital key ↗
08/22/2026Q01438523-I1Request digital key ↗
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION5
12/12/2016421163092Open ↗
10/31/2016440354126Open ↗
07/20/2015421163092Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION4
11/23/2016440354126Open ↗
10/31/2016440354126Open ↗
10/15/2015440170832Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications19
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026Q01438523-I1Open ↗
09/02/2026Q00488708-I1Open ↗
09/02/2026Q00488708-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/22/2026Q01438523-I1Open ↗
08/22/2026Q01438523-S1Open ↗
08/13/2026Q00488708-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026Q01438523-I1Open ↗
09/23/2026Q01438523-S1Open ↗
09/02/2026Q00488708-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
10/31/2016440354126Open ↗
09/21/2014440170832Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
10/31/2016440354126Open ↗
09/21/2014440170832Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
10/31/2016440354126Open ↗
09/21/2014440170832Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/05/2017440354126Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
10/31/2016440354126Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/22/2026Q01438523-S1Open ↗
08/22/2026Q01438523-I1Open ↗
08/13/2026Q00488708-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/30/2015421163092Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/31/2016440354126Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
10/31/2016440354126Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00488708-I1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
10/31/2016440354126Open ↗
09/21/2014440170832Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION2
01/05/2017440354126Open ↗
09/21/2014440170832Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
01/05/2017440354126Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
05/30/2015421163092Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT2
10/31/2016440354126Open ↗
05/30/2015421163092Open ↗
▸BISCIVIL PENALTY AFFADAVIT/REQUEST1
11/21/2016440354126Open ↗
▸Filing & Intake Forms3
▸BISEFILING JOB APPLICATION COVER SHEET2
10/31/2016440354126Open ↗
09/21/2014440170832Open ↗
▸BISEFILING COVER SHEET1
05/30/2015421163092Open ↗
▸Other Documents1
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
10/15/2015440170832Open ↗