← Back
Five to six families
36-23 30 STREET
QUEENS · BIN 4007879
💬 Discuss this project
1921Year Built
3Stories
C2Building Class
R5Zoning
3,645 sfGross Floor Area
6Units
Rent Stabilized14 Open Violations ▸
Five to six families · Owner of record: SERINE HOLDINGS, LLC · 1,800 sf lot · 2.03 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SERINE HOLDINGS507/08/2026
PTP REALTY LLC103/22/2026
PTP REATLY LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/23/2014$1.6M—ATLANTIS PLAZA REALTY LLC → SERINE HOLDINGS, LLC$432/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MVN ARCHITECT LLC101/28/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SOMMA DESIGN CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
REGIONAL ELEC'L VOICE &Electrical103/22/2026
FUTURA BUILDERS GROUP INC.General Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LEO Y LEE ASSOCIATES2481101/28/2025
MVN ARCHITECT LLC5226101/28/2025
Building Lifecycle
All (76)Filed (1)Permit Issued (1)Signed Off (1)Violation (60)Objection (2)Special Inspection (11)
12/11/2025
Signed off — Alteration
SCOPE OF WORK LIMITED TO INTERIOR REPAIRS, CEILING, FLOOR REPAIR AT APT , APT 5F.
Q01172049-I1
11/10/2025
Violation issued (HPD, closed)
B
11/10/2025
Violation issued (HPD, closed)
B
11/03/2025
Violation issued (HPD, closed)
B
11/03/2025
Violation issued (HPD, closed)
C
11/03/2025
Violation issued (HPD, closed)
C
11/03/2025
Violation issued (HPD, closed)
B
11/03/2025
Violation issued (HPD, closed)
C
11/03/2025
Violation issued (HPD, closed)
C
11/03/2025
Violation issued (HPD, closed)
C
11/03/2025
Violation issued (HPD, closed)
C
11/03/2025
Violation issued (HPD, closed)
C
11/03/2025
Violation issued (HPD, closed)
C
11/03/2025
Violation issued (HPD, closed)
C
08/26/2025
Violation issued (HPD, closed)
C
05/30/2025
Permit issued — General Construction
Q01172049-I1-GC
02/06/2025
Objection resolved — Addressed
02/04/2025
Objection raised — Cost
01/28/2025
Filed — Alteration
SCOPE OF WORK LIMITED TO INTERIOR REPAIRS, CEILING, FLOOR REPAIR AT APT , APT 5F.
Q01172049-I1
01/27/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Leo Lee
01/27/2025
Special inspection requirement — Tenant Protection Plan Compliance
Leo Lee
01/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michael Notaro
01/27/2025
Special inspection requirement — Final
Michael Notaro
01/27/2025
Special inspection requirement — Preliminary
Michael Notaro
01/27/2025
Special inspection requirement — Insulation placement and R values
Michael Notaro
01/27/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Michael Notaro
01/27/2025
Special inspection requirement — Fenestration air leakage
Michael Notaro
01/27/2025
Special inspection requirement — Interior lighting power
Michael Notaro
01/27/2025
Special inspection requirement — Lighting controls
Michael Notaro
01/27/2025
Special inspection requirement — Lighting in dwelling units
Michael Notaro
12/06/2024
Violation issued (HPD, closed)
C
10/06/2024
Violation issued (HPD, closed)
B
10/06/2024
Violation issued (HPD, closed)
C
06/07/2024
Violation issued (HPD, closed)
I
05/22/2024
Violation issued (HPD, open)
B
05/22/2024
Violation issued (HPD, closed)
C
05/22/2024
Violation issued (HPD, closed)
C
05/22/2024
Violation issued (HPD, closed)
C
05/22/2024
Violation issued (HPD, closed)
C
05/22/2024
Violation issued (HPD, closed)
B
05/22/2024
Violation issued (HPD, closed)
C
05/22/2024
Violation issued (HPD, closed)
B
05/22/2024
Violation issued (HPD, open)
B
05/22/2024
Violation issued (HPD, open)
B
05/22/2024
Violation issued (HPD, open)
C
05/22/2024
Violation issued (HPD, open)
B
05/22/2024
Violation issued (HPD, open)
C
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/03/2022
Violation issued (HPD, closed)
I
03/03/2022
Violation issued (HPD, closed)
A
06/21/2021
Violation issued (HPD, closed)
B
06/21/2021
Violation issued (HPD, closed)
B
06/21/2021
Violation issued (HPD, closed)
A
06/21/2021
Violation issued (HPD, closed)
A
06/21/2021
Violation issued (HPD, closed)
B
06/21/2021
Violation issued (HPD, closed)
A
06/21/2021
Violation issued (HPD, closed)
B
06/21/2021
Violation issued (HPD, closed)
A
06/21/2021
Violation issued (HPD, open)
C
06/21/2021
Violation issued (HPD, open)
C
Latest 60 of 76 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offGYASI JACKSON05/30/2025
1 project · most recent 11/12/2025
General Wiring
FiledStatusContractorScope
11/12/2025CompleteREGIONAL ELEC'L VOICE &General Wiring
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
01/27/2025Structural Stability – Alterations of existing buildingsLeo Leespecial
01/27/2025Tenant Protection Plan ComplianceLeo Leespecial
01/27/2025Fire-Resistant Penetrations and JointsMichael Notarospecial
01/27/2025FinalMichael Notaroprogress
01/27/2025PreliminaryMichael Notaroprogress
01/27/2025Insulation placement and R valuesMichael Notaroenergy_progress
01/27/2025Fenestration and door U-factor and product ratingsMichael Notaroenergy_progress
01/27/2025Fenestration air leakageMichael Notaroenergy_progress
01/27/2025Interior lighting powerMichael Notaroenergy_progress
01/27/2025Lighting controlsMichael Notaroenergy_progress
01/27/2025Lighting in dwelling unitsMichael Notaroenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026Q01172049-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026Q01172049-I1Open ↗
09/01/2026Q01172049-I1Open ↗
09/01/2026Q01172049-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026Q01172049-I1Open ↗
09/01/2026Q01172049-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01172049-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/13/2026Q01172049-I1Open ↗