← Back
Five to six families
34-23 42 STREET
QUEENS · BIN 4010964
💬 Discuss this project
1922Year Built
3Stories
C2Building Class
R5Zoning
4,992 sfGross Floor Area
6Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Five to six families · Owner of record: B & N STIPANOVIC LLC · 2,800 sf lot · 1.78 FAR built · Flood zone X
Locations of Work
Architecture
Cellar1p · 1 filing · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
B & N STIPANOVIC LLC103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ANTHONY CUCICH ARCHITECT210/07/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PLUMB-IT MECHANICAL INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ANTHONY CUCICH ARCHITECT6081210/07/2024
Building Lifecycle
All (27)Filed (2)Permit Issued (1)Signed Off (1)Violation (2)Inspection (3)Objection (6)Special Inspection (12)
01/07/2025
Signed off — Alteration
NEW WASHER, NEW SLOPE SINK IN THE CELLAR
Q01106079-I1
12/27/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/22/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/22/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/31/2024
Permit issued — Plumbing
Q01106079-I1-PL
10/25/2024
Special inspection requirement — Tenant Protection Plan Compliance
ANTHONY CUCICH
10/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY CUCICH
10/25/2024
Special inspection requirement — Energy Code Compliance Inspections
ANTHONY CUCICH
10/25/2024
Special inspection requirement — Tenant Protection Plan Compliance
ANTHONY CUCICH
10/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY CUCICH
10/25/2024
Special inspection requirement — Energy Code Compliance Inspections
ANTHONY CUCICH
10/24/2024
Objection resolved — Addressed
10/22/2024
Objection raised — Mechanical
10/07/2024
Filed — Alteration
NEW WASHER, NEW SLOPE SINK IN THE CELLAR
Q01106079-P1
10/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY CUCICH
10/07/2024
Special inspection requirement — Tenant Protection Plan Compliance
ANTHONY CUCICH
10/07/2024
Special inspection requirement — Energy Code Compliance Inspections
ANTHONY CUCICH
10/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY CUCICH
10/07/2024
Special inspection requirement — Tenant Protection Plan Compliance
ANTHONY CUCICH
10/07/2024
Special inspection requirement — Energy Code Compliance Inspections
ANTHONY CUCICH
09/24/2024
Objection resolved — Addressed
09/24/2024
Objection resolved — Addressed
09/19/2024
Objection raised — Other
09/19/2024
Objection raised — Admin
09/11/2024
Filed — Alteration
NEW WASHER, NEW SLOPE SINK IN THE CELLAR
Q01106079-I1
11/22/2023
Violation issued (HPD, closed)
I
10/22/2018
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJVR PLBG AND HEATING INC10/31/2024
1 project · most recent 10/08/2024
General Wiring
FiledStatusContractorScope
10/08/2024CompleteRAL-BAR ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
12/27/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/22/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/22/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
10/25/2024Tenant Protection Plan ComplianceANTHONY CUCICHspecial
10/25/2024Fire-Resistant Penetrations and JointsANTHONY CUCICHspecial
10/25/2024Energy Code Compliance InspectionsANTHONY CUCICHprogress
10/25/2024Tenant Protection Plan ComplianceANTHONY CUCICHspecial
10/25/2024Fire-Resistant Penetrations and JointsANTHONY CUCICHspecial
10/25/2024Energy Code Compliance InspectionsANTHONY CUCICHprogress
10/07/2024Fire-Resistant Penetrations and JointsANTHONY CUCICHspecial
10/07/2024Tenant Protection Plan ComplianceANTHONY CUCICHspecial
10/07/2024Energy Code Compliance InspectionsANTHONY CUCICHprogress
10/07/2024Fire-Resistant Penetrations and JointsANTHONY CUCICHspecial
10/07/2024Tenant Protection Plan ComplianceANTHONY CUCICHspecial
10/07/2024Energy Code Compliance InspectionsANTHONY CUCICHprogress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01106079-I1Request digital key ↗
08/21/2026Q01106079-P1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026Q01106079-I1Open ↗
08/21/2026Q01106079-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/22/2026Q01106079-I1Open ↗
08/22/2026Q01106079-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/22/2026Q01106079-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026Q01106079-I1Open ↗
08/21/2026Q01106079-P1Open ↗
▸Other Documents2
▸DOB NOWDHCR Document2
08/13/2026Q01106079-P1Open ↗
08/13/2026Q01106079-I1Open ↗