← Back
Two family brick
23-80 27 STREET
QUEENS · BIN 4018152
💬 Discuss this project
1920Year Built
2Stories
B1Building Class
R5BZoning
2,600 sfGross Floor Area
2Units
0 Open Violations
Two family brick · 2,442 sf lot · 1.06 FAR built · Flood zone X
Locations of Work
Architecture
Floor 13p · 2 filings · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYP707/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STOA DESIGN STUDIO LTD312/18/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FLINT MECHANICAL CORPPlumbing207/08/2026
JOANNE'S CONSTRUCTION COGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STOA DESIGN STUDIO LTD4501212/18/2023
Building Lifecycle
All (32)Filed (3)Permit Issued (3)Signed Off (2)Violation (2)Inspection (5)Special Inspection (17)
01/09/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
01/05/2024
Signed off — Alteration
INTERIOR RENOVATION OF 1ST FLOOR APT. MINOR PARTITION REMOVAL & CONSTRUCTION. NEW KITCHEN & BATHROOM. NEW HARDWOOD FLOORING.
Q00860685-I1
01/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Patrizia Cimino
01/02/2024
Special inspection requirement — Fire-Resistance Rated Construction
Patrizia Cimino
01/02/2024
Special inspection requirement — Final
Patrizia Cimino
01/02/2024
Special inspection requirement — Energy Code Compliance Inspections
Patrizia Cimino
01/02/2024
Special inspection requirement — Interior lighting power
Patrizia Cimino
01/02/2024
Special inspection requirement — Insulation placement and R values
Patrizia Cimino
01/02/2024
Special inspection requirement — Fenestration air leakage
Patrizia Cimino
01/02/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Patrizia Cimino
12/18/2023
Filed — Alteration
INTERIOR RENOVATION OF 1ST FLOOR APT. MINOR PARTITION REMOVAL & CONSTRUCTION. NEW KITCHEN & BATHROOM. NEW HARDWOOD FLOORING.
Q00860685-P1
11/20/2023
Signed off — Alteration
REPLACE 4 PLUMBING FIXTURES. REMOVE 1 PL FIXTURE. ADD 2 NEW PL FIXTURES.
Q00860687-I1
11/20/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Patrizia Cimino
11/20/2023
Special inspection requirement — Energy Code Compliance Inspections
Patrizia Cimino
11/20/2023
Special inspection requirement — Final
Patrizia Cimino
11/20/2023
Special inspection requirement — Fire-Resistance Rated Construction
Patrizia Cimino
11/20/2023
Special inspection requirement — Interior lighting power
Patrizia Cimino
11/20/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Patrizia Cimino
11/20/2023
Special inspection requirement — Fenestration air leakage
Patrizia Cimino
11/20/2023
Special inspection requirement — Insulation placement and R values
Patrizia Cimino
11/03/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/02/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/31/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/30/2023
Permit issued — Plumbing
Q00860687-I1-PL
06/29/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/22/2023
Permit issued — Plumbing
Q00860687-I1-PL
05/18/2023
Permit issued — General Construction
Q00860685-I1-GC
04/19/2023
Filed — Alteration
INTERIOR RENOVATION OF 1ST FLOOR APT. MINOR PARTITION REMOVAL & CONSTRUCTION. NEW KITCHEN & BATHROOM. NEW HARDWOOD FLOORING.
Q00860685-I1
04/19/2023
Filed — Alteration
REPLACE 4 PLUMBING FIXTURES. REMOVE 1 PL FIXTURE. ADD 2 NEW PL FIXTURES.
Q00860687-I1
04/18/2023
Special inspection requirement — Energy Code Compliance Inspections
Patrizia Cimino
08/02/1999
Violation issued (ECB, closed)
Quality of Life
08/02/1999
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offFLINT MECHANICAL CORP10/30/2023
DOB NOWPlumbingSigned-offFLINT MECHANICAL CORP05/22/2023
DOB NOWGeneral ConstructionSigned-offJOANNE'S CONSTRUCTION CO05/18/2023
1 project · most recent 06/07/2023
General Wiring
FiledStatusContractorScope
06/07/2023CompleteTESTA ELECTRIC CO., INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
01/09/2024Fail-Final General Construction Non-Directive 14FailView ↗
11/03/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/02/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/31/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/29/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
01/02/2024Fire-Resistant Penetrations and JointsPatrizia Ciminospecial
01/02/2024Fire-Resistance Rated ConstructionPatrizia Ciminoprogress
01/02/2024FinalPatrizia Ciminoprogress
01/02/2024Energy Code Compliance InspectionsPatrizia Ciminoprogress
01/02/2024Interior lighting powerPatrizia Ciminoenergy_progress
01/02/2024Insulation placement and R valuesPatrizia Ciminoenergy_progress
01/02/2024Fenestration air leakagePatrizia Ciminoenergy_progress
01/02/2024Fenestration and door U-factor and product ratingsPatrizia Ciminoenergy_progress
11/20/2023Fire-Resistant Penetrations and JointsPatrizia Ciminospecial
11/20/2023Energy Code Compliance InspectionsPatrizia Ciminoprogress
11/20/2023FinalPatrizia Ciminoprogress
11/20/2023Fire-Resistance Rated ConstructionPatrizia Ciminoprogress
11/20/2023Interior lighting powerPatrizia Ciminoenergy_progress
11/20/2023Fenestration and door U-factor and product ratingsPatrizia Ciminoenergy_progress
11/20/2023Fenestration air leakagePatrizia Ciminoenergy_progress
11/20/2023Insulation placement and R valuesPatrizia Ciminoenergy_progress
04/18/2023Energy Code Compliance InspectionsPatrizia Ciminoprogress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026Q00860687-I1Request digital key ↗
08/23/2026Q00860685-P1Request digital key ↗
08/23/2026Q00860685-I1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature5
08/30/2026Q00860685-P1Open ↗
08/30/2026Q00860685-P1Open ↗
08/28/2026Q00860687-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026Q00860687-I1Open ↗
08/23/2026Q00860685-I1Open ↗
08/23/2026Q00860685-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026Q00860685-P1Open ↗
08/26/2026Q00860685-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/24/2026Q00860687-I1Open ↗
08/23/2026Q00860685-P1Open ↗
08/23/2026Q00860685-I1Open ↗