| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 07/03/2024 | $1.5M | — | — → — | $541/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| M.A. RUBIANO, P.E., P.C. | 2 | 06/23/2025 |
| KIMOY STUDIOS ARCHITECTURE DPC | 1 | 06/12/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| NYCCODE | 6 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| M INTERIORS CORP | General Contractor | 2 | 04/09/2026 |
| ORBIT PLBG & HTG INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| O'ROURKE ENGINEERING, LLC | 5873 | 3 | 06/23/2025 |
| KIMOY STUDIOS | 3572 | 1 | 06/12/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | ORBIT PLBG & HTG INC | 04/27/2026 |
| DOB NOW | General Construction | Permit Issued | M INTERIORS CORP | 03/25/2026 |
| DOB NOW | General Construction | Permit Issued | M INTERIORS CORP | 02/04/2026 |
| BIS | PL | ISSUED | MAGOR PLG AND HEATING | 05/10/1995 |
| BIS | — | ISSUED | VERTICAL SYSTEMS ANALYSIS | 12/21/1994 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/23/2025 | Permit Issued | M INTERIORS CORP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MITSUBISHI MODEL MXZ-SM48NAM-U1 4 tons · Vrf Outdoor ×1 Ventilation Panasonic FV08-11FL5E 50 CFM · Exhaust Fan ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/10/2026 | Permit Issued | E-POWER ELECTRIC INC | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/18/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 05/14/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/11/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 05/08/2026 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 05/01/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 05/01/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 04/29/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 06/11/2025 | Fenestration and door U-factor and product ratings | John Kim | energy_progress |
| 06/11/2025 | Air barrier - visual inspection | John Kim | energy_progress |
| 06/11/2025 | Insulation placement and R values | John Kim | energy_progress |
| 05/09/2025 | Fire-Resistant Penetrations and Joints | John Kim | special |
| 05/09/2025 | Lighting in dwelling units | John Kim | energy_progress |
| 05/09/2025 | Post-installed Anchors | BRIAN O'ROURKE | special |
| 05/09/2025 | Final | John Kim | progress |