← Back
Three families
20-17 74 STREET
QUEENS · BIN 4020739
💬 Discuss this project
1928Year Built
2Stories
C0Building Class
R4Zoning
2,200 sfGross Floor Area
3Units
Rent Stabilized13 Open Violations 8 unresolved · 5 paperwork only ▸
Three families · 4,000 sf lot · 0.55 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
THE OWNER OF103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EC BUILDING CONSULTANTS. INC410/02/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EC BUILDING CONSULTANTS803/21/2026
Building Lifecycle
All (55)Filed (4)Violation (26)Objection (16)Special Inspection (9)
05/06/2026
Violation issued (HPD, open)
A
11/21/2025
Violation issued (HPD, open)
I
11/06/2025
Objection resolved — Addressed
10/31/2025
Objection raised — Scope
10/02/2025
Filed — Alteration
Demolition of interior partitions at the rear garage and legalization of garage roof structure in response to ECB violation #'s 35215724L, 34865215L, and 34082450K. Also filing open porch legalization. No change to occupancy use or egress.
Q01192015-P1
10/02/2025
Special inspection requirement — Final
06/18/2025
Objection resolved — Addressed
06/18/2025
Objection resolved — Addressed
06/12/2025
Objection resolved — Addressed
06/11/2025
Violation issued (HPD, open)
A
05/12/2025
Objection resolved — Addressed
05/10/2025
Objection resolved — Addressed
04/25/2025
Objection resolved — Addressed
04/24/2025
Objection raised — Plumbing
04/16/2025
Objection resolved — Addressed
04/02/2025
Objection raised — Inspections
04/02/2025
Objection raised — Zoning
04/02/2025
Objection raised — Scope
04/02/2025
Objection raised — Cost
04/02/2025
Objection raised — Other
04/02/2025
Objection raised — Zoning
03/21/2025
Filed — Alteration
Demolition of interior partitions at the rear garage and legalization of garage roof structure in response to ECB violation #'s 35215724L, 34865215L, and 34082450K. Also filing open porch legalization. No change to occupancy use or egress.
Q01192015-I1
12/19/2024
Special inspection requirement — Insulation placement and R values
ANA ACCETTA
12/19/2024
Special inspection requirement — Final
MINKUK KIM
12/19/2024
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
ANA ACCETTA
12/19/2024
Special inspection requirement — Energy Code Compliance Inspections
ANA ACCETTA
12/16/2024
Filed — Alteration
Installation of Exterior Insulation Finishing System (EIFS) as shown on drawings. No change to occupancy use or egress.
Q01140872-P2
12/16/2024
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
12/16/2024
Special inspection requirement — Final
12/16/2024
Special inspection requirement — Insulation placement and R values
12/16/2024
Special inspection requirement — Energy Code Compliance Inspections
12/02/2024
Violation issued (HPD, open)
I
11/12/2024
Filed — Alteration
Installation of Exterior Insulation Finishing System (EIFS) as shown on drawings. No change to occupancy use or egress.
Q01140872-I1
04/15/2024
Violation issued (HPD, open)
A
03/28/2023
Violation issued (HPD, open)
A
11/15/2022
Violation issued (HPD, closed)
I
04/14/2021
Violation issued (HPD, closed)
I
04/14/2021
Violation issued (HPD, closed)
A
11/01/2019
Violation issued (HPD, closed)
I
10/23/2018
Violation issued (HPD, closed)
I
12/04/2017
Violation issued (HPD, closed)
I
02/03/2017
Violation issued (ECB, open)
Construction
11/18/2016
Violation issued (HPD, closed)
I
10/15/2015
Violation issued (HPD, closed)
I
02/26/2015
Violation issued (HPD, closed)
I
07/28/2010
Violation issued (ECB, open)
Unknown
07/26/2000
Violation issued (ECB, closed)
Construction
07/26/2000
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
07/26/2000
Violation issued (ECB, open)
Quality of Life
07/26/2000
Violation issued (ECB, open)
Zoning
12/16/1999
Violation issued (ECB, closed)
Construction
05/24/1999
Violation issued (ECB, closed)
Construction
01/29/1998
Violation issued (ECB, closed)
Construction
06/19/1995
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/16/1993
Violation issued (ECB, open)
Construction
Nothing on file for this building.
1 project · most recent 02/24/2022
FiledStatusContractorScope
02/24/2022CompleteNION ELECTRIC CORP4 new_meters
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
10/02/2025Final—progress
12/19/2024Insulation placement and R valuesANA ACCETTAenergy_progress
12/19/2024FinalMINKUK KIMprogress
12/19/2024Exterior Insulation and Finish Systems (EIFS)ANA ACCETTAspecial
12/19/2024Energy Code Compliance InspectionsANA ACCETTAprogress
12/16/2024Exterior Insulation and Finish Systems (EIFS)—special
12/16/2024Final—progress
12/16/2024Insulation placement and R values—energy_progress
12/16/2024Energy Code Compliance Inspections—progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026Q01140872-I1Request digital key ↗
08/21/2026Q01140872-P2Request digital key ↗
08/20/2026Q01192015-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026Q01140872-P2Open ↗
08/21/2026Q01140872-I1Open ↗
08/20/2026Q01192015-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q01140872-I1Open ↗
08/26/2026Q01140872-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q01140872-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q01192015-I1Open ↗
08/20/2026Q01192015-P1Open ↗