← Back
Two family converted from one family
31-17 76 STREET
QUEENS · BIN 4025660
💬 Discuss this project
1960Year Built
2Stories
B3Building Class
R4Zoning
1,224 sfGross Floor Area
2Units
0 Open Violations
Two family converted from one family · 1,800 sf lot · 0.68 FAR built · Flood zone X
Locations of Work
Architecture
Roof2p · 1 filing · 17 docs
1 job · most recent 03/16/2024
FiledStatusContractorScope
03/16/2024CompleteBERGER QUALITY ELEC'L CON—
Building Lifecycle
All (19)Filed (2)Permit Issued (1)Signed Off (1)Violation (1)Objection (4)Special Inspection (10)
03/06/2025
Signed off — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
Q01016198-I1
02/07/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
02/07/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
02/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
02/07/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
02/07/2025
Special inspection requirement — Final
TOM PETERSEN
02/05/2025
Objection resolved — Addressed
11/07/2024
Objection raised — Other
11/05/2024
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
Q01016198-P1
09/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
09/30/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
09/30/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
09/30/2024
Special inspection requirement — Final
TOM PETERSEN
09/30/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
04/18/2024
Permit issued — Solar
Q01016198-I1-SL
04/09/2024
Objection resolved — Addressed
03/21/2024
Objection raised — Other
03/18/2024
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
Q01016198-I1
12/08/1998
Violation issued (ECB, closed)
Quality of Life
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/09/2023$970K—Private party → Private party$792/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC211/05/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CENTURION SOLAR ENERGYGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854211/05/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offCENTURION SOLAR ENERGY04/18/2024
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
02/07/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
02/07/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
02/07/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
02/07/2025Energy Code Compliance InspectionsTOM PETERSENprogress
02/07/2025FinalTOM PETERSENprogress
09/30/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
09/30/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
09/30/2024Energy Code Compliance InspectionsTOM PETERSENprogress
09/30/2024FinalTOM PETERSENprogress
09/30/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/23/2026Q01016198-I1Request digital key ↗
08/14/2026Q01016198-P1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
11/28/2022402436770Open ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/27/2026Q01016198-I1Open ↗
09/27/2026Q01016198-I1Open ↗
09/27/2026Q01016198-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/27/2026Q01016198-I1Open ↗
09/27/2026Q01016198-I1Open ↗
08/24/2026Q01016198-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q01016198-P1Open ↗
08/13/2026Q01016198-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q01016198-P1Open ↗
08/13/2026Q01016198-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01016198-I1Open ↗