← Back
Two family brick
32-22 82 STREET
QUEENS · BIN 4026933
💬 Discuss this project
1920Year Built
2Stories
B1Building Class
R4Zoning
2,176 sfGross Floor Area
2Units
Two family brick · 3,550 sf lot · 0.61 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
Nothing on file for this building.
Building Lifecycle
All (16)Filed (3)Permit Issued (2)Signed Off (2)Inspection (3)Special Inspection (6)
01/06/2025
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING TWO FAMILY HOUSE. FLOORING, PAINTING, ETC. NO CHANGE IN EGRESS AND CERTIFICATE OF OCCUPANCY.
Q01074138-S1
01/06/2025
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING TWO FAMILY HOUSE. FLOORING, PAINTING, ETC. NO CHANGE IN EGRESS AND CERTIFICATE OF OCCUPANCY.
Q01074138-I1
10/11/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/11/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/08/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/02/2024
Special inspection requirement — HVAC-R and service water heating equipment
WANLONG HE
10/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
WANLONG HE
10/02/2024
Special inspection requirement — Energy Code Compliance Inspections
WANLONG HE
10/01/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING TWO FAMILY HOUSE. FLOORING, PAINTING, ETC. NO CHANGE IN EGRESS AND CERTIFICATE OF OCCUPANCY.
Q01074138-P1
09/16/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
WANLONG HE
09/16/2024
Special inspection requirement — Energy Code Compliance Inspections
WANLONG HE
09/16/2024
Special inspection requirement — HVAC-R and service water heating equipment
WANLONG HE
08/12/2024
Permit issued — Plumbing
Q01074138-S1-PL
08/12/2024
Permit issued — General Construction
Q01074138-I1-GC
08/06/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING TWO FAMILY HOUSE. FLOORING, PAINTING, ETC. NO CHANGE IN EGRESS AND CERTIFICATE OF OCCUPANCY.
Q01074138-S1
08/05/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING TWO FAMILY HOUSE. FLOORING, PAINTING, ETC. NO CHANGE IN EGRESS AND CERTIFICATE OF OCCUPANCY.
Q01074138-I1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/06/2024$1.5M—— → —$676/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HWL ENGINEERING PC310/01/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HCNY MANAGEMENT603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ZL BUILDING ASSOCIATE INCGeneral Contractor303/21/2026
ROCK E SMALL PLBG&HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HWL ENGINEERING PC3894310/01/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offROCK E SMALL PLBG&HTG INC08/12/2024
DOB NOWGeneral ConstructionSigned-offZL BUILDING ASSOCIATE INC08/12/2024
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
10/11/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/11/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/08/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
10/02/2024HVAC-R and service water heating equipmentWANLONG HEenergy_progress
10/02/2024Fire-Resistant Penetrations and JointsWANLONG HEspecial
10/02/2024Energy Code Compliance InspectionsWANLONG HEprogress
09/16/2024Fire-Resistant Penetrations and JointsWANLONG HEspecial
09/16/2024Energy Code Compliance InspectionsWANLONG HEprogress
09/16/2024HVAC-R and service water heating equipmentWANLONG HEenergy_progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026Q01074138-I1Request digital key ↗
08/21/2026Q01074138-P1Request digital key ↗
08/21/2026Q01074138-S1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
09/23/2026Q01074138-S1Open ↗
09/23/2026Q01074138-S1Open ↗
08/24/2026Q01074138-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026Q01074138-S1Open ↗
08/13/2026Q01074138-I1Open ↗
08/13/2026Q01074138-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026Q01074138-S1Open ↗
08/24/2026Q01074138-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026Q01074138-S1Open ↗
08/13/2026Q01074138-I1Open ↗
08/13/2026Q01074138-P1Open ↗