← Back
General warehouse
37-30 60 STREET
QUEENS · BIN 4027760
💬 Discuss this project
1958Year Built
1Stories
E1Building Class
R5BZoning
9,000 sfGross Floor Area
2Units
0 Open Violations
General warehouse · Owner of record: WILKOFF PROPERTIES, LLC · 9,000 sf lot · 1 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JETCO CONSTRUCTION CORP503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BANGASH ASSOCIATES INC.104/08/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ARC-HI-TECT ASSOCIATE203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JETCO CONSTRUCTION CORPGeneral Contractor203/21/2026
LINVAL BROWNElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARC-HI-TECH ASSOCIATES IN6963104/08/2025
Building Lifecycle
All (18)Filed (1)Permit Issued (1)Signed Off (1)Violation (12)Special Inspection (3)
08/21/2025
Signed off — Alteration
APPLICATION FOR REPAIR CRACKS OBSERVED AT BUILDING FACADE (FRONT AND SIDE) AS PER FIELD CONDITION TO COMPLY ECBVIOLATION #39138836P. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01207194-I1
08/12/2025
Permit issued — General Construction
Q01207194-I1-GC
04/08/2025
Filed — Alteration
APPLICATION FOR REPAIR CRACKS OBSERVED AT BUILDING FACADE (FRONT AND SIDE) AS PER FIELD CONDITION TO COMPLY ECBVIOLATION #39138836P. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01207194-I1
04/08/2025
Special inspection requirement — Tenant Protection Plan Compliance
IGOR LISOVENKO
04/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
IGOR LISOVENKO
04/08/2025
Special inspection requirement — Final
IGOR LISOVENKO
02/19/2025
Violation issued (ECB, closed)
Construction
02/19/2025
Violation issued (ECB, closed)
Construction
03/10/2023
Violation issued (ECB, closed)
Construction
09/15/2010
Violation issued (ECB, closed)
Plumbing
09/08/2010
Violation issued (ECB, closed)
Unknown
05/08/2009
Violation issued (ECB, closed)
Construction
03/19/2008
Violation issued (ECB, closed)
Administrative
03/10/2008
Violation issued (ECB, closed)
Construction
02/12/2008
Violation issued (ECB, closed)
Construction
12/27/2007
Violation issued (ECB, closed)
Construction
03/09/2005
Violation issued (ECB, closed)
Quality of Life
03/09/2005
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offJETCO CONSTRUCTION08/12/2025
BISPLISSUEDTHE PLUMBING COMPANY INC05/16/2005
BISOTISSUEDN/A05/13/2005
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
04/08/2025Tenant Protection Plan ComplianceIGOR LISOVENKOspecial
04/08/2025Structural Stability – Alterations of existing buildingsIGOR LISOVENKOspecial
04/08/2025FinalIGOR LISOVENKOprogress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01207194-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026Q01207194-I1Open ↗
08/23/2026Q01207194-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/20/2026Q01207194-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026Q01207194-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/20/2026Q01207194-I1Open ↗