| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/08/2026 | — | — | Air Conditioning Systems, Ventilation Systems | Cooling Trane YHK102A3SAM 3,600 CFM · Rooftop Unit ×2 YHK210A3SAL 6,225 CFM · Rooftop Unit ×2 YHK240A3SBL 7,000 CFM · Rooftop Unit ×2 YCD360DEM 10,400 CFM · Rooftop Unit ×1 YCD420DEP 12,000 CFM · Rooftop Unit ×1 YHK060A3SAL 1,600 CFM · Rooftop Unit ×1 YHK072A3SAL 2,000 CFM · Rooftop Unit ×1 YHK102A3SAL 2,550 CFM · Rooftop Unit ×1 YHK180A3SBL 5,000 CFM · Rooftop Unit ×1 YHK210A3SAM 6,020 CFM · Rooftop Unit ×1 YHK240A3SAM 7,000 CFM · Rooftop Unit ×1 YSK120A3SAL 4,450 CFM · Rooftop Unit ×1 Mitsubishi Electric PKA-AL18NL 15,900 BTU · Split System ×1 Ventilation Greenheck USF-12-B6 2,300 CFM · Exhaust Fan ×1 USF-13-B6 4,060 CFM · Exhaust Fan ×1 Upblast VG 840 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/08/2026 | — | — | Gas |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/25/2025 | Complete | GEMINI ELECTRIC CO., INC. | — |
| 02/18/2020 | Complete | TOP SHELF ELECTRIC CORP | — |
| 07/28/2019 | Permit Issued | BRANDL ELECTRIC INC. | General Wiring |
| Owner | Filings | Most Recent |
|---|---|---|
| SERVIENTREGA | 3 | 03/22/2026 |
| 82-01 37TH STORE, LLC | 2 | 03/22/2026 |
| D.O.E. RENAISSANCE CHART0 | 2 | 03/22/2026 |
| 82-01 37TH STORE LLC SCWA | 3 | 03/22/2026 |
| DEPT. OF EDUCATION 0 | 1 | 03/22/2026 |
| 82-01 37 AVE STORE LLC | 2 | 03/22/2026 |
| 8201 37 STORE LLC | 3 | 03/22/2026 |
| THE RENAISSANCE SCHOOL DO | 7 | 03/22/2026 |
| 37 AVE PALACE LLC | 1 | 03/22/2026 |
| A & C DEPARTMENT STORE | 2 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| LIRO-HILL | 2 | 07/08/2026 |
| ALLEN SHINFELD, P.E. PLLC | 1 | 03/10/2023 |
| THE LIRO GROUP | 2 | 02/02/2022 |
| DOOLING & COMPANY ARCHITECTS | 1 | 02/12/2020 |
| TOHFAZ UDDIN PE PC | 1 | 02/12/2020 |
| Representative | Filings | Most Recent |
|---|---|---|
| AE DESIGN SOLUTION | 4 | 03/21/2026 |
| YOUN DESIGN CORP | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| SPRING SCAFFOLDING LLC | General Contractor | 5 | 07/08/2026 |
| BRANDL ELECTRIC INC. | Electrical | 1 | 03/22/2026 |
| GEMINI ELECTRIC CO., INC. | Electrical | 1 | 03/22/2026 |
| NEPTUNE SIGNS AWNINGS | Scaffold | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| UNIVERSAL TESTING AND INS | 400 | 1 | 02/01/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sign | Signed-off | NEPTUNE SIGNS&AWNINGS INC | 05/25/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | SPRING SCAFFOLDING LLC | 12/15/2020 |
| DOB NOW | Sidewalk Shed | Signed-off | SPRING SCAFFOLDING LLC | 02/14/2020 |
| DOB NOW | Supported Scaffold | Signed-off | SPRING SCAFFOLDING LLC | 02/13/2020 |
| BIS | EQ | ISSUED | SPRING SCAFFOLDING LLC | 02/18/2020 |
| BIS | OT | ISSUED | PALM CONSTRUCTION INC | 09/22/2016 |
| BIS | FP | ISSUED | CHIEF FIRE PREV.& MECH CO | 06/11/2009 |
| BIS | OT | ISSUED | UNIVERSAL CONTRACTING OF | 08/22/2008 |
| BIS | — | ISSUED | PAUL SIGNS, INC | 10/09/2002 |
| BIS | — | ISSUED | PAUL SIGNS, INC | 10/09/2002 |
| BIS | OT | ISSUED | STONEWALL CONTRACTING CORP | 01/19/2000 |
| BIS | PL | ISSUED | PR PLUMBING | 01/19/2000 |
| BIS | OT | ISSUED | STONEWALL CONTRACTING CORP | 01/19/2000 |
| BIS | EQ | RE-ISSUED | YORK SCAFFOLD EQUIPMENT CORP. | 09/16/1999 |
| BIS | OT | ISSUED | MONARCH CONSTRUCTION CORP | 08/13/1998 |
| BIS | OT | ISSUED | MONARCH CONSTRUCTION CORPORATION | 08/13/1998 |
| BIS | PL | ISSUED | PANZERA IMPROVEMENT CORP. | 12/16/1997 |
| BIS | MH | ISSUED | PANZERA IMPROVEMENT CORP | 12/03/1997 |
| BIS | EQ | ISSUED | PANZERA IMPROVEMENT CORP | 12/03/1997 |
| BIS | OT | ISSUED | PANZERA IMPROVEMENT CORP | 12/03/1997 |
| BIS | BL | ISSUED | PANZERA IMPROVEMENT CORP. | 10/30/1997 |
| BIS | PL | ISSUED | PANZERA IMPROVEMENT CORP. | 10/30/1997 |
| BIS | MH | ISSUED | PANZERA IMPRO CONST | 08/11/1997 |
| BIS | FP | ISSUED | B J FIRE INC T/A FIRE MASTERS | 08/29/1996 |
| BIS | PL | ISSUED | N/A | 01/22/1996 |
| BIS | EQ | ISSUED | PANZERA IMPROVEMENTS CORP | 01/02/1996 |
| BIS | — | ISSUED | PANZERA IMPROVEMENTS CORP | 01/02/1996 |
| BIS | OT | ISSUED | PANZERA IMP. CORP. | 11/09/1995 |
| BIS | MH | ISSUED | PANZERA IMP. CORP. | 08/31/1995 |
| BIS | SP | ISSUED | OMEGA SPRINKLER CO INC | 12/14/1990 |
| BIS | SP | ISSUED | A & C ANTOINETTE FAS. SHOP INC | 12/20/1989 |
| BIS | EQ | ISSUED | A & C ANTOINETTE FAS. SHOP INC | 09/05/1989 |
| Date | Type | Result | Report |
|---|---|---|---|
| 06/28/2023 | Pass-Final Sign Permit Inspection | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/08/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 03/15/2022 | Energy Code Compliance Inspections | — | progress |
| 03/11/2022 | Shutoff dampers | — | energy_progress |
| 03/11/2022 | Post-installed Anchors | — | special |
| 03/11/2022 | Fire-Resistant Penetrations and Joints | — | special |
| 02/01/2022 | Fire-Resistant Penetrations and Joints | — | special |
| 01/13/2022 | HVAC-R and service water heating equipment | — | energy_progress |
| 01/13/2022 | Maintenance information | — | energy_progress |
| 01/13/2022 | HVAC-R and service water heating system controls | — | energy_progress |
| 01/13/2022 | Duct leakage testing, insulation and design | — | energy_progress |
| 01/13/2022 | Final | NELSON LOPEZ | progress |
| 01/13/2022 | Mechanical Systems | NELSON LOPEZ | special |
| 02/10/2020 | Final | MARK DOOLING | progress |