← Back
Elevator apt, semi-fireproof without stores
41-20 ELBERTSON STREET
QUEENS · BIN 4038856
💬 Discuss this project
1940Year Built
6Stories
D1Building Class
R7BZoning
55,526 sfGross Floor Area
60Units
0 Open Violations
Elevator apt, semi-fireproof without stores · Owner of record: 88-36 ELMHURST AVENUE, LLC · 11,598 sf lot · 4.79 FAR built
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction10p · 1 filing · 20 docs
Floor 1Under Construction11p · 1 filing · 20 docs
CellarUnder Construction11p · 1 filing · 20 docs
1 job · most recent 08/19/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/19/2026Permit IssuedCK COOLING & HEATING INCAir Conditioning Systems
Cooling
Gree RI009HP115VIAO 24,000 BTU · Condensing Unit ×4
1 job · most recent 08/19/2026
Gas Water/Sanitary
FiledStatusContractorScope
08/19/2026Permit IssuedTRI STATE PLBG & HTG INCGas, Water/Sanitary
2 jobs · most recent 09/22/2026
General Wiring
FiledStatusContractorScope
09/22/2026Permit IssuedGALAXY ELECTRIC CORPGeneral Wiring
03/19/2026Permit IssuedI.P. ELECTRIC INCGeneral Wiring
Building Lifecycle
All (27)Filed (2)Permit Issued (2)Violation (3)Objection (2)Special Inspection (18)
08/24/2026
Permit issued — Plumbing
Q01382315-S1-PL
08/19/2026
Filed — Alteration CO
INTERIOR RENOVATION IN CELLAR, 1ST AND 2ND FLOOR AS PER PLAN. CONVERT ONE FAMILY TO TWO FAMILIES. OBTAIN NEW C OF O.
Q01382315-S1
08/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Fangliang Chen
08/17/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Fangliang Chen
08/17/2026
Special inspection requirement — HVAC-R and service water heating equipment
Fangliang Chen
08/17/2026
Special inspection requirement — HVAC-R and service water heating system controls
Fangliang Chen
08/17/2026
Special inspection requirement — Permanent certificate
Fangliang Chen
08/13/2026
Permit issued — General Construction
Q01382315-I1-GC-CX
05/11/2026
Special inspection requirement — Maintenance information
KY FU
05/11/2026
Special inspection requirement — Ventilation and air distribution system
KY FU
05/11/2026
Special inspection requirement — Metering
KY FU
04/21/2026
Objection raised — Mechanical
04/21/2026
Objection raised — Scope
04/08/2026
Filed — Alteration CO
INTERIOR RENOVATION IN CELLAR, 1ST AND 2ND FLOOR AS PER PLAN. CONVERT ONE FAMILY TO TWO FAMILIES. OBTAIN NEW C OF O.
Q01382315-I1
04/02/2026
Special inspection requirement — Energy Code Compliance Inspections
KY FU
04/02/2026
Special inspection requirement — Mechanical Systems
KY FU
04/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
KY FU
04/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
KY FU
04/02/2026
Special inspection requirement — Permanent certificate
KY FU
04/02/2026
Special inspection requirement — Air barrier - visual inspection
KY FU
04/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
KY FU
04/02/2026
Special inspection requirement — Interior lighting power
KY FU
04/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
04/02/2026
Special inspection requirement — Final
KY FU
12/14/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/08/2011
Violation issued (HPD, closed)
C
06/28/2011
Violation issued (ECB, closed)
Construction
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GOODLAND BUILD & DESIGN108/19/2026
FLUSHING ENGINEERING SERVICE PC104/08/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CK COOLING & HEATING INCGeneral Contractor108/14/2026
TRI STATE PLBG & HTG INCPlumbing108/25/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GOODLAND DESIGN AND BUILD9715108/19/2026
FLUSHING ENGINEERING SERV4373104/08/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedTRI STATE PLBG & HTG INC08/24/2026
DOB NOWGeneral ConstructionPermit IssuedCK COOLING & HEATING INC08/13/2026
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
08/17/2026Fire-Resistant Penetrations and JointsFangliang Chenspecial
08/17/2026HVAC-R and service water piping design and insulationFangliang Chenenergy_progress
08/17/2026HVAC-R and service water heating equipmentFangliang Chenenergy_progress
08/17/2026HVAC-R and service water heating system controlsFangliang Chenenergy_progress
08/17/2026Permanent certificateFangliang Chenenergy_progress
05/11/2026Maintenance informationKY FUenergy_progress
05/11/2026Ventilation and air distribution systemKY FUenergy_progress
05/11/2026MeteringKY FUenergy_progress
04/02/2026Energy Code Compliance InspectionsKY FUprogress
04/02/2026Mechanical SystemsKY FUspecial
04/02/2026HVAC-R and service water heating system controlsKY FUenergy_progress
04/02/2026HVAC-R and service water heating equipmentKY FUenergy_progress
04/02/2026Permanent certificateKY FUenergy_progress
04/02/2026Air barrier - visual inspectionKY FUenergy_progress
04/02/2026HVAC-R and service water piping design and insulationKY FUenergy_progress
04/02/2026Interior lighting powerKY FUenergy_progress
04/02/2026Fire-Resistant Penetrations and JointsKY FUspecial
04/02/2026FinalKY FUprogress
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026Q01382315-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
06/17/2008410095061Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026Q01382315-I1Open ↗
▸Seals & Professional Certifications23
▸DOB NOWProgress Inspector Seal & Signature15
09/01/2026Q01382315-S1Open ↗
09/01/2026Q01382315-S1Open ↗
09/01/2026Q01382315-S1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026Q01382315-S1Open ↗
08/27/2026Q01382315-I1Open ↗
08/27/2026Q01382315-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q01382315-S1Open ↗
08/17/2026Q01382315-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
04/09/2008410095061Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
04/09/2008410095061Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
04/09/2008410095061Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
04/09/2008410095061Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/15/2026Q01382315-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q01382315-S1Open ↗
08/15/2026Q01382315-I1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
04/09/2008410095061Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSCHEDULE A - OCCUPANCY / USE2
12/15/2008410095061Open ↗
04/09/2008410095061Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
04/09/2008410095061Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
04/09/2008410095061Open ↗
▸Other Documents2
▸BISPLOT DIAGRAM1
04/09/2008410095061Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026Q01382315-I1Open ↗