← Back
Two family converted from one family
97-63 CORONA AVENUE
QUEENS · BIN 4040631
💬 Discuss this project
1935Year Built
2.5Stories
B3Building Class
R5Zoning
1,632 sfGross Floor Area
2Units
4 Open Violations ▸
Two family converted from one family · 2,045 sf lot · 0.8 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction1p · 1 filing · 10 docs
Floor 1Under Construction1p · 1 filing · 10 docs
CellarUnder Construction2p · 1 filing · 10 docs
1 job · most recent 10/10/2024
Water/Sanitary
FiledStatusContractorScope
10/10/2024Permit IssuedSIGNORE & SONS PLBG CORPWater/Sanitary
Building Lifecycle
All (23)Filed (2)Permit Issued (2)Violation (8)Inspection (7)Special Inspection (4)
03/23/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/23/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/17/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/23/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/23/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/23/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/09/2025
Permit issued — Plumbing
Q01091379-S1-PL
08/01/2025
Permit issued — General Construction
Q01091379-I1-GC
05/29/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
RAYMOND CALAMARI
10/10/2024
Filed — Alteration
Propose to legalize washing machine in cellar, 2 pc bathroom at first floor. Propose to cap and remove 2 backwash on first floor. Cap and remove 3 pc bathroom from attic level.
Q01091379-S1
10/07/2024
Violation issued (ECB, closed)
Construction
10/07/2024
Violation issued (ECB, closed)
Construction
10/07/2024
Violation issued (ECB, closed)
Construction
10/07/2024
Violation issued (ECB, closed)
Construction
10/07/2024
Violation issued (ECB, open)
Unknown
10/07/2024
Violation issued (ECB, open)
Construction
10/07/2024
Violation issued (ECB, open)
Construction
08/19/2024
Filed — Alteration
Propose to legalize washing machine in cellar, 2 pc bathroom at first floor. Propose to cap and remove 2 backwash on first floor. Cap and remove 3 pc bathroom from attic level.
Q01091379-I1
08/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
RAYMOND CALAMARI
08/05/2024
Special inspection requirement — Final
LUZ MORAIMA DISLA
08/05/2024
Special inspection requirement — Fire-Resistance Rated Construction
RAYMOND CALAMARI
06/27/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARCALHEK210/10/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A&A BUILDING CONSULTANTS INC.403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A&A BUILDING CONSULTANTSGeneral Contractor104/09/2026
SIGNORE & SONS PLBG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARCALHEK PC3340210/10/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedSIGNORE & SONS PLBG CORP10/09/2025
DOB NOWGeneral ConstructionPermit IssuedA&A BUILDING CONSULTANTS08/01/2025
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
03/23/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/23/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/17/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/23/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/23/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/23/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/29/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
10/23/2024Fire-Resistant Penetrations and JointsRAYMOND CALAMARIspecial
08/05/2024Fire-Resistant Penetrations and JointsRAYMOND CALAMARIspecial
08/05/2024FinalLUZ MORAIMA DISLAprogress
08/05/2024Fire-Resistance Rated ConstructionRAYMOND CALAMARIprogress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01091379-I1Request digital key ↗
08/21/2026Q01091379-S1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026Q01091379-I1Open ↗
08/21/2026Q01091379-S1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026Q01091379-I1Open ↗
08/24/2026Q01091379-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026Q01091379-I1Open ↗
08/24/2026Q01091379-S1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026Q01091379-S1Open ↗
08/21/2026Q01091379-I1Open ↗