← Back
All parking garages
32-27 111 STREET
QUEENS · BIN 4042317
💬 Discuss this project
1963Year Built
1Stories
G1Building Class
R4Zoning
1,100 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
All parking garages · Owner of record: 3233, LLC · 2,363 sf lot · 0.47 FAR built · Flood zone X
Locations of Work
Electrical
Permit Issued — active, not yet Signed-off
RoofUnder Construction1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
URBAN FOUNDATION ENGINEERING107/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC105/27/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802105/27/2026
Building Lifecycle
All (10)Filed (1)Permit Issued (1)Violation (1)Inspection (2)Special Inspection (5)
08/25/2026
Violation issued (ECB, open)
Construction
08/20/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/04/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/08/2026
Permit issued — Solar
Q01407919-I1-SL
05/27/2026
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01407919-I1
05/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
05/27/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
05/27/2026
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
05/27/2026
Special inspection requirement — Final
Kaijin Liang
05/27/2026
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedKAMTECH RESTORATION CORP06/08/2026
1 project · most recent 05/26/2026
FiledStatusContractorScope
05/26/2026Permit IssuedBERGER QUALITY ELEC'L CON—
1 project · most recent 05/27/2026
FiledStatusContractorScope
05/27/2026Permit IssuedKAMTECH RESTORATION CORP28 panels, 16.38 kw, 1,060.73 roof_area_sqft
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/20/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/04/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/27/2026Fire-Resistant Penetrations and JointsKaijin Liangspecial
05/27/2026Structural Stability – Alterations of existing buildingsKaijin Liangspecial
05/27/2026Energy Code Compliance InspectionsKaijin Liangprogress
05/27/2026FinalKaijin Liangprogress
05/27/2026Air barrier - visual inspectionKaijin Liangenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026Q01407919-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/24/2026Q01407919-I1Open ↗
08/24/2026Q01407919-I1Open ↗
08/24/2026Q01407919-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026Q01407919-I1Open ↗
08/24/2026Q01407919-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026Q01407919-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026Q01407919-I1Open ↗