← Back
Two family frame
108-59 53 AVENUE
QUEENS · BIN 4049750
💬 Discuss this project
1960Year Built
2Stories
B2Building Class
R5Zoning
1,475 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 2,500 sf lot · 0.59 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/07/2015$750K—— → —$508/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC110/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AMERGY SOLAR203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AMERGY SOLAR INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802110/21/2025
Building Lifecycle
All (9)Filed (1)Permit Issued (1)Signed Off (1)Violation (1)Special Inspection (5)
01/12/2026
Signed off — Alteration
Installation of Solar panels on existing roof structure, No change in use, egress or occupancy.
Q01294301-I1
10/27/2025
Permit issued — Solar
Q01294301-I1-SL
10/21/2025
Filed — Alteration
Installation of Solar panels on existing roof structure, No change in use, egress or occupancy.
Q01294301-I1
09/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Chun Feng
09/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Chun Feng
09/29/2025
Special inspection requirement — Energy Code Compliance Inspections
Chun Feng
09/29/2025
Special inspection requirement — Final
Chun Feng
09/29/2025
Special inspection requirement — Air barrier - visual inspection
Chun Feng
05/07/2014
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offAMERGY SOLAR INC10/27/2025
1 project · most recent 10/19/2025
FiledStatusContractorScope
10/19/2025CompleteI.P. ELECTRIC INC—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
09/29/2025Fire-Resistant Penetrations and JointsChun Fengspecial
09/29/2025Structural Stability – Alterations of existing buildingsChun Fengspecial
09/29/2025Energy Code Compliance InspectionsChun Fengprogress
09/29/2025FinalChun Fengprogress
09/29/2025Air barrier - visual inspectionChun Fengenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026Q01294301-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026Q01294301-I1Open ↗
08/25/2026Q01294301-I1Open ↗
08/25/2026Q01294301-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q01294301-I1Open ↗
08/25/2026Q01294301-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/18/2026Q01294301-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/18/2026Q01294301-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01294301-I1Open ↗